← Všechny firmy
FIRMA

InDro Robotics

Přidáno 08. 10. 2026 · 13:27Poslední vyhodnocení:
SKÓRE FIRMY

Střední shoda

Podloženo 3 ze 4 kroků ověření. Chybí zdroj nalezení firmy.

Produkty

Zjištění a důkazy

Včetně historie změn
AgileX Bunker Mini 2.0Další doložená specifikaceDoložený údaj ear speed and rotation angular speed of the chassis can be controlled through the external CAN bus interface; BUNKER MINI will feedback the current motion status information and the status information of the BUNKER MINI chassis in real time. The protocol includes system status feedback frames, motion control feedback frames, and control frames. The protocol content is as follows: ● ● 18/40 The system status feedback command includes current car body status feedback, control mode status feedback, battery voltage feedback and fault feedback. The protocol content is shown in Table 3.1: Table 3.1 BUNKER MINI 2.0 Chassis State Feedback Frame Command name System state feedback command Sending node Receiving Node ID Cycle(ms) Receiving Timeout (ms) Wire-controlled chassis Decision control unit 0x211 200ms None Data length 0x08 Location Function Data Type Description byte [0] Current vehicle body state unsigned int8 0x00 System normal 0x01 Emergency shut-down mode 0x02 System exception byte [1] Mode control unsigned int8 0x00 Standby mode 0x01 CAN command control mode 0x03 Remote control mode byte [2] The upper eight bits of battery voltage unsigned int16 Actual voltage X10 (accurate to 0.1V) byte [3] The lower eight bits of battery voltage byte [4] Reserved - 0x00 byte [5] Fault information unsigned int8 For details, see [Fault Information Description] byte [6] Reserved - 0x00 19/40 Table 3.2 Explanation table of fault information The motion control feedback frame command includes the feedback of current vehicle body’s motion linear velocity and motion angular velocity. The specific content of the protocol is shown in Table 3.3. Table 3.3 Motion Control Feedback Frame byte [7] C
ear speed and rotation angular speed of the chassis can be controlled through the external CAN bus interface; BUNKER MINI will feedback the current motion status information and the status information of the BUNKER MINI chassis in real time. The protocol includes system status feedback frames, motion control feedback frames, and control frames. The protocol content is as follows: ● ● 18/40 The system status feedback command includes current car body status feedback, control mode status feedback, battery voltage feedback and fault feedback. The protocol content is shown in Table 3.1: Table 3.1 BUNKER MINI 2.0 Chassis State Feedback Frame Command name System state feedback command Sending node Receiving Node ID Cycle(ms) Receiving Timeout (ms) Wire-controlled chassis Decision control unit 0x211 200ms None Data length 0x08 Location Function Data Type Description byte [0] Current vehicle body state unsigned int8 0x00 System normal 0x01 Emergency shut-down mode 0x02 System exception byte [1] Mode control unsigned int8 0x00 Standby mode 0x01 CAN command control mode 0x03 Remote control mode byte [2] The upper eight bits of battery voltage unsigned int16 Actual voltage X10 (accurate to 0.1V) byte [3] The lower eight bits of battery voltage byte [4] Reserved - 0x00 byte [5] Fault information unsigned int8 For details, see [Fault Information Description] byte [6] Reserved - 0x00 19/40 Table 3.2 Explanation table of fault information The motion control feedback frame command includes the feedback of current vehicle body’s motion linear velocity and motion angular velocity. The specific content of the protocol is shown in Table 3.3. Table 3.3 Motion Control Feedback Frame byte [7] C
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 73100-74800
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/BUNKER-MINI-2.0-User-Manual.pdf
Místo v podkladu
Product source excerpt, characters 73100-74800
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX BunkerDalší doložená specifikaceDoložený údaj t, BUNKER chassis will accept the command from CAN interface, and the host can also parse the current state of chassis with the real-time data fed back from CAN bus. For the detailed content of protocol, please refer to CAN communication protocol. 3.4 Firmware upgrades In order to facilitate users to upgrade the firmware version used by BUNKER and bring customers a more complete experience, BUNKER provides a firmware upgrade hardware interface and corresponding client software. Upgrade Preparation Agilex CAN debugging module X 1 Micro USB cable X 1 BUNKER 2.0 chassis X 1 A computer (WINDOWS OS (Operating System)) X 1 ● ● ● ● 26/35 Upgrade Process 1.Plug in the USBTOCAN module on the computer, and then open the AgxCandoUpgradeToolV1.3_boxed.exe software (the sequence cannot be wrong, first open the software and then plug in the module, the device will not be recognized). 2.Click the Open Serial button, and then press the power button on the car body. If the connection is successful, the version information of the main control will be recognized, as shown in the figure. 3.Click the Load Firmware File button to load the firmware to be upgraded. If the loading is successful, the firmware information will be obtained, as shown in the figure 27/35  4.Click the node to be upgraded in the node list box, and then click Start Upgrade Firmware to start upgrading the firmware. After the upgrade is successful, a pop-up box will prompt.  28/35 3.5 BUNKER ROS Package Use Example ROS provide some standard operating system services, such as hardware abstraction, low-level device control, implementation of common function, interprocess message and data packet management. ROS is based on a
t, BUNKER chassis will accept the command from CAN interface, and the host can also parse the current state of chassis with the real-time data fed back from CAN bus. For the detailed content of protocol, please refer to CAN communication protocol. 3.4 Firmware upgrades In order to facilitate users to upgrade the firmware version used by BUNKER and bring customers a more complete experience, BUNKER provides a firmware upgrade hardware interface and corresponding client software. Upgrade Preparation Agilex CAN debugging module X 1 Micro USB cable X 1 BUNKER 2.0 chassis X 1 A computer (WINDOWS OS (Operating System)) X 1 ● ● ● ● 26/35 Upgrade Process 1.Plug in the USBTOCAN module on the computer, and then open the AgxCandoUpgradeToolV1.3_boxed.exe software (the sequence cannot be wrong, first open the software and then plug in the module, the device will not be recognized). 2.Click the Open Serial button, and then press the power button on the car body. If the connection is successful, the version information of the main control will be recognized, as shown in the figure. 3.Click the Load Firmware File button to load the firmware to be upgraded. If the loading is successful, the firmware information will be obtained, as shown in the figure 27/35  4.Click the node to be upgraded in the node list box, and then click Start Upgrade Firmware to start upgrading the firmware. After the upgrade is successful, a pop-up box will prompt.  28/35 3.5 BUNKER ROS Package Use Example ROS provide some standard operating system services, such as hardware abstraction, low-level device control, implementation of common function, interprocess message and data packet management. ROS is based on a
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 71400-73100
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:37
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/Bunker-User-Manual.pdf
Místo v podkladu
Product source excerpt, characters 71400-73100
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX Ranger Mini 2.0 (historical manual)Další doložená specifikaceDoložený údaj No. 7 motor driver bit [4] communication status (0: unfaulty; 1: faulty) No. 8 motor driver bit [5] communication status (0: unfaulty; 1: faulty) Over temperature protection bit [6] status (0: normal; 1: triggered) Over current protection bit [7] status (0: normal; 1: triggered) byte [7] Battery undervoltage status bit [0] (0: normal; 1: triggered) Reserved, the default value is bit [1] 0 Remote control lost bit [2] connection protection status (0: normal; 1: triggered) No. 1 motor driver bit [3] communication status (0: unfaulty; 1: faulty) No. 2 motor driver bit [4] communication status (0: unfaulty; 1: faulty) No. 3 motor driver bit [5] communication status (0: unfaulty; 1: faulty) No. 4 motor driver bit [6] communication status (0: unfaulty; 1: faulty) 23 / 52 Reserved, the default value is bit [7]
No. 7 motor driver bit [4] communication status (0: unfaulty; 1: faulty) No. 8 motor driver bit [5] communication status (0: unfaulty; 1: faulty) Over temperature protection bit [6] status (0: normal; 1: triggered) Over current protection bit [7] status (0: normal; 1: triggered) byte [7] Battery undervoltage status bit [0] (0: normal; 1: triggered) Reserved, the default value is bit [1] 0 Remote control lost bit [2] connection protection status (0: normal; 1: triggered) No. 1 motor driver bit [3] communication status (0: unfaulty; 1: faulty) No. 2 motor driver bit [4] communication status (0: unfaulty; 1: faulty) No. 3 motor driver bit [5] communication status (0: unfaulty; 1: faulty) No. 4 motor driver bit [6] communication status (0: unfaulty; 1: faulty) 23 / 52 Reserved, the default value is bit [7]
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 30600-32300
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/RANGER-MINI-2.0-User-Manual.pdf
Místo v podkladu
Product source excerpt, characters 30600-32300
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX LIMODalší doložená specifikaceDoložený údaj so automatically start the ROS Master, and can realize various configurations of each node, which provides great convenience for the operation of multiple nodes. (1) Launch tag The launch tag is like a generous bracket that defines an area. All launch files start with < launch> and end with < /launch>. All description tags must be written between < launch> and < /launch> (2)Node tag The node tag can be said to be the most common tag in the launch file. Each node tag includes the name attribute of the node in the ROS graph (name), the package name where the node is located (pkg), and the type of the node (type). The common usage is as follows: roslaunch limo_base limo_base.launch rosrun learning_limo listener rosrun learning_limo talker <launch> …… …… </launch> <node pkg="package-name" type="executable-name" name="node-name" /> Tag attribute Attribute function pkg="PACKAGE_NAME" The name of the package where the node is located type="FILE_NAME" Define the executable file name of the node output="screen" Print the standard output of the node to the terminal screen, and the default output is a log file. respawn="true" Reset the properties. When the node stops, it will automatically restart. The default is false. ns = "NAME_SPACE" Namespace, which adds a namespace prefix to the relative name in the node. args="arguments" Input parameters required by the node. Tag attribute Attribute function file ="$(find pkg-name)/path/filename.xml" Specify the files you want to include (3)Include tag This tag can import another roslaunch XML file to the current file. Use it like this: (4)Remap tag The remap tag is remapping. ROS supports topic remapping. The remap tag contains an original-
so automatically start the ROS Master, and can realize various configurations of each node, which provides great convenience for the operation of multiple nodes. (1) Launch tag The launch tag is like a generous bracket that defines an area. All launch files start with < launch> and end with < /launch>. All description tags must be written between < launch> and < /launch> (2)Node tag The node tag can be said to be the most common tag in the launch file. Each node tag includes the name attribute of the node in the ROS graph (name), the package name where the node is located (pkg), and the type of the node (type). The common usage is as follows: roslaunch limo_base limo_base.launch rosrun learning_limo listener rosrun learning_limo talker <launch> …… …… </launch> <node pkg="package-name" type="executable-name" name="node-name" /> Tag attribute Attribute function pkg="PACKAGE_NAME" The name of the package where the node is located type="FILE_NAME" Define the executable file name of the node output="screen" Print the standard output of the node to the terminal screen, and the default output is a log file. respawn="true" Reset the properties. When the node stops, it will automatically restart. The default is false. ns = "NAME_SPACE" Namespace, which adds a namespace prefix to the relative name in the node. args="arguments" Input parameters required by the node. Tag attribute Attribute function file ="$(find pkg-name)/path/filename.xml" Specify the files you want to include (3)Include tag This tag can import another roslaunch XML file to the current file. Use it like this: (4)Remap tag The remap tag is remapping. ROS supports topic remapping. The remap tag contains an original-
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 244800-246500
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/limo-standard-user-manual-en.pdf
Místo v podkladu
Product source excerpt, characters 244800-246500
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX LIMODalší doložená specifikaceDoložený údaj that is, the workspace. 4.1.2 What is a workspace Workspace is a folder for storing project development related files. ROS after the Fuerte version uses the Catkin compilation system by default. The workspace structure under a typical Catkin compilation system is as follows. A typical workspace generally includes the following four directory spaces. (1) src: code space, the most commonly used folder in the development process, used to store the source code files of all ROS packages. (2) build: compilation space, used to store the cache information and intermediate files generated during the compilation of the workspace. (3) devel: development space, used to place executable files generated by compilation. (4) lib: installation library space. After the compilation is successful, you can use the make install command to install the executable files into the space, and run the environment variable scripts in the space to run these executable files in the terminal. The installation library space is not necessary, and this folder may not be available in many workspaces. 4.2.2 Create a workspace The command to create a workspace is relatively simple. First, use the system command to create the workspace directory, and then run the ROS workspace initialization command to complete the creation process: Create a folder named catkin_ws and continue to create a folder named src under catkin_ws. mkdir -p ~/catkin_ws/src Switch to the src folder under the catkin_ws folder. cd ~/catkin_ws/src Initialize the folder. catkin_init_workspace After the creation is complete, the catkin_make command can be used to compile the entire workspace in the root directory
that is, the workspace. 4.1.2 What is a workspace Workspace is a folder for storing project development related files. ROS after the Fuerte version uses the Catkin compilation system by default. The workspace structure under a typical Catkin compilation system is as follows. A typical workspace generally includes the following four directory spaces. (1) src: code space, the most commonly used folder in the development process, used to store the source code files of all ROS packages. (2) build: compilation space, used to store the cache information and intermediate files generated during the compilation of the workspace. (3) devel: development space, used to place executable files generated by compilation. (4) lib: installation library space. After the compilation is successful, you can use the make install command to install the executable files into the space, and run the environment variable scripts in the space to run these executable files in the terminal. The installation library space is not necessary, and this folder may not be available in many workspaces. 4.2.2 Create a workspace The command to create a workspace is relatively simple. First, use the system command to create the workspace directory, and then run the ROS workspace initialization command to complete the creation process: Create a folder named catkin_ws and continue to create a folder named src under catkin_ws. mkdir -p ~/catkin_ws/src Switch to the src folder under the catkin_ws folder. cd ~/catkin_ws/src Initialize the folder. catkin_init_workspace After the creation is complete, the catkin_make command can be used to compile the entire workspace in the root directory
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 85000-86700
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/limo-standard-user-manual-en.pdf
Místo v podkladu
Product source excerpt, characters 85000-86700
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX Scout 2.0Další doložená specifikaceDoložený údaj d power supply here is internally controlled, which means the power supply will be actively cut off once the battery voltage drops below the pre-specified threshold voltage. Therefore, users need to notice that SCOUT 2.0 platform will send a low voltage alarm before the threshold voltage is reached and also pay attention to battery recharging during use. 1 2 3 Function and Pin No. Pin Type Remarks Definition 1 Power positive, voltage range Power VCC 23 - 29.2V, MAX.current 10A 2 Power GND Power negative 3 CAN CAN_H CAN bus high 4 CAN CAN_L CAN bus low
d power supply here is internally controlled, which means the power supply will be actively cut off once the battery voltage drops below the pre-specified threshold voltage. Therefore, users need to notice that SCOUT 2.0 platform will send a low voltage alarm before the threshold voltage is reached and also pay attention to battery recharging during use. 1 2 3 Function and Pin No. Pin Type Remarks Definition 1 Power positive, voltage range Power VCC 23 - 29.2V, MAX.current 10A 2 Power GND Power negative 3 CAN CAN_H CAN bus high 4 CAN CAN_L CAN bus low
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 17000-18700
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/SCOUT2.0-USER-MANUAL-3.0.pdf
Místo v podkladu
Product source excerpt, characters 17000-18700
Zaznamenání
Ruční záznam · public-product-review-20261024
Firmasource documentDoložený údaj Research using InDro robots for real-world autonomy - InDro Robotics
Research using InDro robots for real-world autonomy
Zdroj: indrorobotics.ca ↗ Public source inventory; original text retained
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:27
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/research-using-indro-robots-for-real-world-autonomy/
Místo v podkladu
Public source inventory; original text retained
Zaznamenání
Ruční záznam · public-product-review-20261024
Unitree B1 (historical manual)Další doložená specifikaceDoložený údaj e whether the users need to use the remote control according to the running state of the robot. Remote control commands fail during low-level development. This chapter is an introductory chapter for new users to manipulate robots. New users can quickly master how to use the handle to control the robot to show excellent movement performance by reading this section. This chapter is also a chapter thatold usersoften need to refer to.Old userscan read this chapter repeatedly tograsp theessentials ofoperating the robot, and then they can draw inferences from case, and know what kind of movements are not recommended. Operation Environment Requirement 1) Run the robot in -5°C -55°C with good weather condition. Do not operate in bad weather, such as lightning and tornado weather. When operating in water, the users need to be sure to comply with the requirements described in the IP67 Protection level instructions. 2) Please keep it under control in the users’ view when using the robot and keep the robot maintain a safe distance of at least 2 meters from obstacles, complex ground, crowds, water, and other objects. 3) Please do not run the robot in an electromagnetic interference environment. Sources of electromagnetic interference include but are not limited to: high-voltage power lines, high-voltage transmission stations, mobile phone base stations, and television broadcast towers. 4) PleasedonotruntherobotintheWiFisignalinterferenceenvironment.WiFisignalinterferenceisusually caused by co-channel interference. In case of interference, be sure to turn off some or all WiFi signal sources of other wireless devices before using the remote control to operate the robot. 5) Due to the di
e whether the users need to use the remote control according to the running state of the robot. Remote control commands fail during low-level development. This chapter is an introductory chapter for new users to manipulate robots. New users can quickly master how to use the handle to control the robot to show excellent movement performance by reading this section. This chapter is also a chapter thatold usersoften need to refer to.Old userscan read this chapter repeatedly tograsp theessentials ofoperating the robot, and then they can draw inferences from case, and know what kind of movements are not recommended. Operation Environment Requirement 1) Run the robot in -5°C -55°C with good weather condition. Do not operate in bad weather, such as lightning and tornado weather. When operating in water, the users need to be sure to comply with the requirements described in the IP67 Protection level instructions. 2) Please keep it under control in the users’ view when using the robot and keep the robot maintain a safe distance of at least 2 meters from obstacles, complex ground, crowds, water, and other objects. 3) Please do not run the robot in an electromagnetic interference environment. Sources of electromagnetic interference include but are not limited to: high-voltage power lines, high-voltage transmission stations, mobile phone base stations, and television broadcast towers. 4) PleasedonotruntherobotintheWiFisignalinterferenceenvironment.WiFisignalinterferenceisusually caused by co-channel interference. In case of interference, be sure to turn off some or all WiFi signal sources of other wireless devices before using the remote control to operate the robot. 5) Due to the di
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 159800-161500
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/unitree-b1-user-manual.pdf
Místo v podkladu
Product source excerpt, characters 159800-161500
Zaznamenání
Ruční záznam · public-product-review-20261024
Firmasource documentDoložený údaj InDro flies in urban wind tunnels for National Research Council - InDro Robotics
InDro Robotics flies in urban wind tunnels for National Research Council project
Zdroj: indrorobotics.ca ↗ Public source inventory; original text retained
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:34
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/indro-robotics-flies-in-urban-wind-tunnels-for-national-research-council-project/
Místo v podkladu
Public source inventory; original text retained
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX LIMO ProDalší doložená specifikaceDoložený údaj a compiler. Compilation rules are specified in the CMakeLists.txt file within the package. This file is generated automatically when creating a package using the catkin command. Most compilation options have been configured with detailed comments. External documentation may not be necessary since code can be compiled with minor modifications. The CMakeLists.txt file in the package can be opened to locate configuration items. Comments can be removed, and adjustments can be made as required. include_directories(include ${catkin_INCLUDE_DIRS}) add_executable(talker src/talker.cpp) target_link_libraries(talker ${catkin_LIBRARIES}) add_dependencies(talker ${PROJECT_NAME}_generate_messages_cpp) add_executable(listener src/listener.cpp) target_link_libraries(listener ${catkin_LIBRARIES}) add_dependencies(talker ${PROJECT_NAME}_generate_messages_cpp) 4.3.4 Run Publisher and Subscriber Upon completion of the compilation, the next step involves executing the Publisher and Subscriber nodes. Prior to initiating these nodes, it is essential to configure the environment variables within the terminal. This ensures that the executable files produced by the package's final compilation are detectable: Switch to the catkin_ws directory: cd ~/catkin_ws Set environment variables: source ./devel/setup.bash The configuration script of environment variables can also be added to the configuration file of the terminal: echo "source ~/catkin_ws/devel/setup.bash" >> ~/.bashrc source ~/.bashrc In Limo, the environment variables have been set. Start the routine according to the following steps: 1. Launch the chassis node Note: Before running the comman
a compiler. Compilation rules are specified in the CMakeLists.txt file within the package. This file is generated automatically when creating a package using the catkin command. Most compilation options have been configured with detailed comments. External documentation may not be necessary since code can be compiled with minor modifications. The CMakeLists.txt file in the package can be opened to locate configuration items. Comments can be removed, and adjustments can be made as required. include_directories(include ${catkin_INCLUDE_DIRS}) add_executable(talker src/talker.cpp) target_link_libraries(talker ${catkin_LIBRARIES}) add_dependencies(talker ${PROJECT_NAME}_generate_messages_cpp) add_executable(listener src/listener.cpp) target_link_libraries(listener ${catkin_LIBRARIES}) add_dependencies(talker ${PROJECT_NAME}_generate_messages_cpp) 4.3.4 Run Publisher and Subscriber Upon completion of the compilation, the next step involves executing the Publisher and Subscriber nodes. Prior to initiating these nodes, it is essential to configure the environment variables within the terminal. This ensures that the executable files produced by the package's final compilation are detectable: Switch to the catkin_ws directory: cd ~/catkin_ws Set environment variables: source ./devel/setup.bash The configuration script of environment variables can also be added to the configuration file of the terminal: echo "source ~/catkin_ws/devel/setup.bash" >> ~/.bashrc source ~/.bashrc In Limo, the environment variables have been set. Start the routine according to the following steps: 1. Launch the chassis node Note: Before running the comman
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 108800-110500
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:42
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/limo-pro-user-manual-en.pdf
Místo v podkladu
Product source excerpt, characters 108800-110500
Zaznamenání
Ruční záznam · public-product-review-20261024
Firmasource documentDoložený údaj Uncategorized Archives - InDro Robotics
A Canadian First: InDro’s Prowler Robots Part of Museum Security Team
Zdroj: indrorobotics.ca ↗ Public source inventory; original text retained
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:32
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/category/uncategorized/
Místo v podkladu
Public source inventory; original text retained
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX TitanDalší doložená specifikaceDoložený údaj The brake needs to be unlocked to control the speed of the chassis 24 / 49 Command CAN upgrade bus silent mode setting command Node for sending Node for receiving ID Period (ms) Receive timeout (ms) Decision-making Node for the 0x422 None None and control unit chassis Data length 0x01 Byte Meaning Data type Note 0x00 Exit CAN upgrade bus silent mode 0x01 Enter CAN upgrade bus silent mode byte [0] Control mode unsigned int8 In CAN upgrade bus silent mode, the chassis VCU pauses sending CAN data to the bus for firmware upgrade, and resumes data feedback
The brake needs to be unlocked to control the speed of the chassis 24 / 49 Command CAN upgrade bus silent mode setting command Node for sending Node for receiving ID Period (ms) Receive timeout (ms) Decision-making Node for the 0x422 None None and control unit chassis Data length 0x01 Byte Meaning Data type Note 0x00 Exit CAN upgrade bus silent mode 0x01 Enter CAN upgrade bus silent mode byte [0] Control mode unsigned int8 In CAN upgrade bus silent mode, the chassis VCU pauses sending CAN data to the bus for firmware upgrade, and resumes data feedback
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 37400-39100
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/TITAN-User-Manual.pdf
Místo v podkladu
Product source excerpt, characters 37400-39100
Zaznamenání
Ruční záznam · public-product-review-20261024
Unitree Go1 (historical manual)Další doložená specifikaceDoložený údaj 2021 Unitree Robotics. All Rights Reserved 2 GO1 User Manual Statements and Warnings 1.This product is not a toy and is not suitable for people under the age of 18. Do not allow children to come into contact with this product.· 2.Please read this document carefully before using the product to understand how to use this product correctly and understand your legal rights, responsibilities and safety instructions; otherwise, it may bring property damage, safety accidents and personal safety hazards. By using this product, you are deemed to have understood, endorsed and accepted all and part of the terms and conditions of this document. The user is committed to being responsible for his or her actions and all consequences arising therefrom. The user undertakes to use the product solely for legitimate purposes and agrees to these terms and any relevant policies or guidelines that may be established by Unitree. 3.To the fullest extent permitted by law, Unitree does not make any warranties, express or implied, with respect to this product, including but not limited to warranties of merchantability, fitness for a particular purpose, or non-infringement. To the fullest extent permitted by law, Unitree shall not be liable for any damages resulting from the user's failure to use the product in accordance with this document. Not liable for any indirect, consequential, punitive, incidental, special or penalties, including damages incurred as a result of your purchase, use or inability to use the product (even if Unitree ha
2021 Unitree Robotics. All Rights Reserved 2 GO1 User Manual Statements and Warnings 1.This product is not a toy and is not suitable for people under the age of 18. Do not allow children to come into contact with this product.· 2.Please read this document carefully before using the product to understand how to use this product correctly and understand your legal rights, responsibilities and safety instructions; otherwise, it may bring property damage, safety accidents and personal safety hazards. By using this product, you are deemed to have understood, endorsed and accepted all and part of the terms and conditions of this document. The user is committed to being responsible for his or her actions and all consequences arising therefrom. The user undertakes to use the product solely for legitimate purposes and agrees to these terms and any relevant policies or guidelines that may be established by Unitree. 3.To the fullest extent permitted by law, Unitree does not make any warranties, express or implied, with respect to this product, including but not limited to warranties of merchantability, fitness for a particular purpose, or non-infringement. To the fullest extent permitted by law, Unitree shall not be liable for any damages resulting from the user's failure to use the product in accordance with this document. Not liable for any indirect, consequential, punitive, incidental, special or penalties, including damages incurred as a result of your purchase, use or inability to use the product (even if Unitree ha
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 6800-8500
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/go1_user_manual.pdf
Místo v podkladu
Product source excerpt, characters 6800-8500
Zaznamenání
Ruční záznam · public-product-review-20261024
Firmasource documentDoložený údaj How remote inspection robots like Sentinel reduce downtime - InDro Robotics
How remote inspection robots reduce downtime
Zdroj: indrorobotics.ca ↗ Public source inventory; original text retained
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:42
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/how-remote-inspection-robots-reduce-downtime/
Místo v podkladu
Public source inventory; original text retained
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX Bunker Mini 2.0Další doložená specifikaceDoložený údaj ical personnel and do not handle it without authorization. 5 / 40 CONTENTS 6 / 40 CONTENTS Document version Safety Information CONTENTS 1 Introduction of BUNKER MINI 2.0 1.1 Product List 1.2 Performance parameters 1.3 Required for development 2 The Basics 2.1 Electrical interface description 2.2 Remote control instructions 2.3 Control command and motion description 3 Getting Started 3.1 Use and operation 3.2 Charging 3.3 Development 3.3.1 CAN Cable Connection 3.3.2 CAN protocol description 3.3.3 BUNKER MINI 2.0 ROS Package Usage Example 4 Use and operation 5 Q&A 6 Product Dimensions 6.1 Illustrations of product outline dimensions 6.2 Illustrations of top expansion bracket dimensions 7 / 40 1 Introduction of BUNKER MINI 2.0 BUNKER MINI 2.0is an all-round tracked chassis vehicle for industrial applications. It is featured with simple and sensitive operation, large development space, adaptability to development and application in various fields, IP67 dustproof and waterproof, and great gradeability, etc. It can be used for the development of special robots such as inspection and exploration, EOD rescue, special shooting, and special transport, and is a solution to robot movement. 1.1 Product List Name Quantity BUNKER MINI 2.0robot body x1 Battery charger (AC 220V) x1
ical personnel and do not handle it without authorization. 5 / 40 CONTENTS 6 / 40 CONTENTS Document version Safety Information CONTENTS 1 Introduction of BUNKER MINI 2.0 1.1 Product List 1.2 Performance parameters 1.3 Required for development 2 The Basics 2.1 Electrical interface description 2.2 Remote control instructions 2.3 Control command and motion description 3 Getting Started 3.1 Use and operation 3.2 Charging 3.3 Development 3.3.1 CAN Cable Connection 3.3.2 CAN protocol description 3.3.3 BUNKER MINI 2.0 ROS Package Usage Example 4 Use and operation 5 Q&A 6 Product Dimensions 6.1 Illustrations of product outline dimensions 6.2 Illustrations of top expansion bracket dimensions 7 / 40 1 Introduction of BUNKER MINI 2.0 BUNKER MINI 2.0is an all-round tracked chassis vehicle for industrial applications. It is featured with simple and sensitive operation, large development space, adaptability to development and application in various fields, IP67 dustproof and waterproof, and great gradeability, etc. It can be used for the development of special robots such as inspection and exploration, EOD rescue, special shooting, and special transport, and is a solution to robot movement. 1.1 Product List Name Quantity BUNKER MINI 2.0robot body x1 Battery charger (AC 220V) x1
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 8500-10200
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/BUNKER-MINI-2.0-User-Manual.pdf
Místo v podkladu
Product source excerpt, characters 8500-10200
Zaznamenání
Ruční záznam · public-product-review-20261024
Unitree Go1 (historical manual)Další doložená specifikaceDoložený údaj he table in this section correspond to each other. When the user runs the program developed by himself in the developer mode: the handle command is still valid during high-level (application layer) development. At this time, if the high-level API command and the handle command are sent to the robot together, the robot will execute both commands, which may cause the robot Instability, please be sure to judge whether you need to use the handle control according to the running state of the robot. The handle command is invalid during the low-level development. New players can learn the operation through the operation video tutorial or the quick start manual This chapter is also a chapter that old players need to check frequ、ently Since the robot does not have a visual perception system at present, and the actual control personnel have different levels of control proficiency, in order to be reliable and stable, please use it in an open and flat environment. When operating the robot, be careful to avoid steps above 5cm, slopes greater than 25°, and obstacles that may cause the robot to fall. When the robot is walking on a terrain with a certain undulation or slope, the controller should reduce the walking speed of the robot and carefully control it so that the robot is tripped by obstacles. Foot robots have certain requirements for the ground to walk. Do not use robots on the ground with insufficient friction, such as ice. Do not use robots on soft ground, such as thicker sponge/turf floors. For use on smoother floors, such as glass, tiles, etc., carefully and compliantly c
he table in this section correspond to each other. When the user runs the program developed by himself in the developer mode: the handle command is still valid during high-level (application layer) development. At this time, if the high-level API command and the handle command are sent to the robot together, the robot will execute both commands, which may cause the robot Instability, please be sure to judge whether you need to use the handle control according to the running state of the robot. The handle command is invalid during the low-level development. New players can learn the operation through the operation video tutorial or the quick start manual This chapter is also a chapter that old players need to check frequ、ently Since the robot does not have a visual perception system at present, and the actual control personnel have different levels of control proficiency, in order to be reliable and stable, please use it in an open and flat environment. When operating the robot, be careful to avoid steps above 5cm, slopes greater than 25°, and obstacles that may cause the robot to fall. When the robot is walking on a terrain with a certain undulation or slope, the controller should reduce the walking speed of the robot and carefully control it so that the robot is tripped by obstacles. Foot robots have certain requirements for the ground to walk. Do not use robots on the ground with insufficient friction, such as ice. Do not use robots on soft ground, such as thicker sponge/turf floors. For use on smoother floors, such as glass, tiles, etc., carefully and compliantly c
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 44200-45900
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/go1_user_manual.pdf
Místo v podkladu
Product source excerpt, characters 44200-45900
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX Tracer MiniDalší doložená specifikaceDoložený údaj Enter standby mode by default after power on Note[1] Control mode description The default control mode is the standby mode, and you need to switch to the command mode to send the motion control command. If the remote control is turned on, it has the highest authority and can block the control of commands. When the remote control switches to the command mode, it still needs to send the control mode setting command before responding to the speed command. The state setting frame is used to clear system errors, and its specific protocol content is shown in Table 3.8. Table 3.8 State setting frame description table Command name State setting command Sending node Receiving node ID ( ) Cycle ms Receiving Timeo ut (ms) Wire-controlled Decision control 0x441 None None chassis unit Data length 0x01 23 / 37 Position Function Data type Description 0x00 Clear all errors byte [0] Control mode unsigne
Enter standby mode by default after power on Note[1] Control mode description The default control mode is the standby mode, and you need to switch to the command mode to send the motion control command. If the remote control is turned on, it has the highest authority and can block the control of commands. When the remote control switches to the command mode, it still needs to send the control mode setting command before responding to the speed command. The state setting frame is used to clear system errors, and its specific protocol content is shown in Table 3.8. Table 3.8 State setting frame description table Command name State setting command Sending node Receiving node ID ( ) Cycle ms Receiving Timeo ut (ms) Wire-controlled Decision control 0x441 None None chassis unit Data length 0x01 23 / 37 Position Function Data type Description 0x00 Clear all errors byte [0] Control mode unsigne
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 40800-42500
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/TRACER_MINI_E-BOOK.pdf
Místo v podkladu
Product source excerpt, characters 40800-42500
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX LIMODalší doložená specifikaceDoložený údaj e files to be used limomsg.py Drive to the required messages limo.py Main program, used to drive limo A script is provided to call the driver. The directory of it is agilex_ws/src/limo_ros/limo_base/script, and the name is limomove.py. This directory can be accessed with the following command. Open a terminal and enter the command in the terminal: Note: Before running the command, please make sure that the programs in other terminals have been terminated. The termination command is: Ctrl+c. cd agilex_ws/src/limo_ros/limo_base/script Run the script. Open the terminal, and enter the command in the terminal: python3 limomove.py After entering the command in the terminal, limo will walk a certain distance before stopping. Functions used in the driver: Name Function EnableCommand() Control enable SetMotionCommand() Set motion command GetLinearVelocity() Get linear velocity GetAngularVelocity() Get angular velocity GetSteeringAngle() Get steering angle GetLateralVelocity() Get lateral velocity GetControlMode() Get control mode GetBatteryVoltage() Get battery level GetErrorCode() Get error code GetRightWheelOdem() Get left wheel odometer GetLeftWheelOdem() Get right wheel odometer GetIMUAccelData()
e files to be used limomsg.py Drive to the required messages limo.py Main program, used to drive limo A script is provided to call the driver. The directory of it is agilex_ws/src/limo_ros/limo_base/script, and the name is limomove.py. This directory can be accessed with the following command. Open a terminal and enter the command in the terminal: Note: Before running the command, please make sure that the programs in other terminals have been terminated. The termination command is: Ctrl+c. cd agilex_ws/src/limo_ros/limo_base/script Run the script. Open the terminal, and enter the command in the terminal: python3 limomove.py After entering the command in the terminal, limo will walk a certain distance before stopping. Functions used in the driver: Name Function EnableCommand() Control enable SetMotionCommand() Set motion command GetLinearVelocity() Get linear velocity GetAngularVelocity() Get angular velocity GetSteeringAngle() Get steering angle GetLateralVelocity() Get lateral velocity GetControlMode() Get control mode GetBatteryVoltage() Get battery level GetErrorCode() Get error code GetRightWheelOdem() Get left wheel odometer GetLeftWheelOdem() Get right wheel odometer GetIMUAccelData()
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 25500-27200
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/limo-standard-user-manual-en.pdf
Místo v podkladu
Product source excerpt, characters 25500-27200
Zaznamenání
Ruční záznam · public-product-review-20261024
Unitree Go1 (historical manual)Další doložená specifikaceDoložený údaj floors. For use on smoother floors, such as glass, tiles, etc., carefully and compliantly control the robot to exercise, avoid strenuous exercise, and reduce the walking speed of the robot to prevent the robot's foot from slipping and falling. GO1 User Manual 2021 Unitree All Rights Reserved22 Label controller This section describes the features of the label controller and includes instructions for controlling the quadruped robot。 GO1 User Manual Copyright © 2021 Unitree Robotics. All Rights Reserved23 Label controller Label controller Introduction The tag is part of the Go1 remote control module. It can control the robot to achieve full control of the 3-axis posture and 3-axis position stability when standing, and it can also control the robot to move forward and backward, move left and right, turn on the spot, and walk according to certain rules on a flat ground. (Straight line, circle, arc, rectangle), creeping, up and down slopes/steps, running in place, etc. The handle adopts a new folding design, which is more convenient to carry Technical specifications: [1] Receiving antenna [2] Control joystick [3] Infrared rays [4] Battery indicator [5] Charging port Type C [6] (+) [7] (-) [8] MOD button [9] POW button GO1 User Manual Copyright © 2021 Unitree Robotics. All Rights Reserved24 parameter 规格 备注 Charging voltage 5.0V recharging current 500mA Lithium battery capacity 300mAH stand-by current 5uA operation hours 5h Remote control distance Above 15M frequency 4243.2–4742.4 MHz The allowable height of the remote control from the ground when following sideways 0.6m~1.2m(Approximately at the waist of the human body) Button Description: button Function Instructions POW Power
floors. For use on smoother floors, such as glass, tiles, etc., carefully and compliantly control the robot to exercise, avoid strenuous exercise, and reduce the walking speed of the robot to prevent the robot's foot from slipping and falling. GO1 User Manual 2021 Unitree All Rights Reserved22 Label controller This section describes the features of the label controller and includes instructions for controlling the quadruped robot。 GO1 User Manual Copyright © 2021 Unitree Robotics. All Rights Reserved23 Label controller Label controller Introduction The tag is part of the Go1 remote control module. It can control the robot to achieve full control of the 3-axis posture and 3-axis position stability when standing, and it can also control the robot to move forward and backward, move left and right, turn on the spot, and walk according to certain rules on a flat ground. (Straight line, circle, arc, rectangle), creeping, up and down slopes/steps, running in place, etc. The handle adopts a new folding design, which is more convenient to carry Technical specifications: [1] Receiving antenna [2] Control joystick [3] Infrared rays [4] Battery indicator [5] Charging port Type C [6] (+) [7] (-) [8] MOD button [9] POW button GO1 User Manual Copyright © 2021 Unitree Robotics. All Rights Reserved24 parameter 规格 备注 Charging voltage 5.0V recharging current 500mA Lithium battery capacity 300mAH stand-by current 5uA operation hours 5h Remote control distance Above 15M frequency 4243.2–4742.4 MHz The allowable height of the remote control from the ground when following sideways 0.6m~1.2m(Approximately at the waist of the human body) Button Description: button Function Instructions POW Power
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 124100-125800
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:28
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/go1_user_manual.pdf
Místo v podkladu
Product source excerpt, characters 124100-125800
Zaznamenání
Ruční záznam · public-product-review-20261024
AgileX BunkerDalší doložená specifikaceDoložený údaj 4 / 35 35 / 35 [READING ORDER TEXT] 1/35   BUNKER AgileX Robotics Team USER MANUAL V.2.0.0 2023.09 Document version BUNKER USER MANUAL No. Version Date Edited by Reviewer Notes 1 V1.0.0 2023/03/17 谢瑞亲  Document creation 2/35 Safety Information This chapter contains important safety information, before the robot is powered on for he first time, any individual or organization must read and understand this information before using the device. If you have any questions about use, please contact us at support@agilex.ai. Please follow and implement all assembly instructions and guidelines in the chapters of this manual, which is very important. Particular attention should be paid to the text related to the warning signs. The information in this manual does not include the design, installation and operation of a complete robot application, nor does it include all peripheral equipment that may affect the safety of the complete system. The design and use of the complete system need to comply with the safety requirements established in the standards and regulations of the country where the robot is installed. BUNKER integrators and end customers have the responsibility to ensure compliance with the applicable laws and regulations of relevant countries, and to ensure that there are no major dangers in the complete robot application. This includes but is not limited to the following: Effectiveness and responsibility Make a risk assessment of the complete robot system. Connect the additional safety equipment of other machinery defined by the risk assessment together. Confirm that the design and installation of the entire robot system's peripheral equipment, including software and ha
4 / 35 35 / 35 [READING ORDER TEXT] 1/35   BUNKER AgileX Robotics Team USER MANUAL V.2.0.0 2023.09 Document version BUNKER USER MANUAL No. Version Date Edited by Reviewer Notes 1 V1.0.0 2023/03/17 谢瑞亲  Document creation 2/35 Safety Information This chapter contains important safety information, before the robot is powered on for he first time, any individual or organization must read and understand this information before using the device. If you have any questions about use, please contact us at support@agilex.ai. Please follow and implement all assembly instructions and guidelines in the chapters of this manual, which is very important. Particular attention should be paid to the text related to the warning signs. The information in this manual does not include the design, installation and operation of a complete robot application, nor does it include all peripheral equipment that may affect the safety of the complete system. The design and use of the complete system need to comply with the safety requirements established in the standards and regulations of the country where the robot is installed. BUNKER integrators and end customers have the responsibility to ensure compliance with the applicable laws and regulations of relevant countries, and to ensure that there are no major dangers in the complete robot application. This includes but is not limited to the following: Effectiveness and responsibility Make a risk assessment of the complete robot system. Connect the additional safety equipment of other machinery defined by the risk assessment together. Confirm that the design and installation of the entire robot system's peripheral equipment, including software and ha
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 47600-49300
Zobrazit uložený podklad Získáno 24. 10. 2026 · 21:37
Podrobnosti zjištění
Zdroj
https://indrorobotics.ca/wp-content/uploads/2024/07/Bunker-User-Manual.pdf
Místo v podkladu
Product source excerpt, characters 47600-49300
Zaznamenání
Ruční záznam · public-product-review-20261024