                             USER MANUAL V.2.0.0         2023.09




Document version

                                  Edited
 No.   Version        Date                    Reviewer                  Notes
                                    by

 1         V1.0.0   2023/03/17    谢瑞亲                             Document creation




                                           1 / 35
                                                                   Remote control data update
                                                                   Synchronize the operation of
   2      V2.0.0     2023/09/01        吴忠义                            github official website
                                                                 Bunker chassis firmware tutorial
                                                                     Adjust document format


   3      V2.0.1      2023/09/02       谢瑞亲              
                                                                       Add rendering image
                                                                       Document checking




Safety Information
This chapter contains important safety information, before the robot is powered on for he
first time, any individual or organization must read and understand this information before
using the device. If you have any questions about use, please contact us at
support@agilex.ai . Please follow and implement all assembly instructions and guidelines in
the chapters of this manual, which is very important. Particular attention should be paid to
the text related to the warning signs.

The information in this manual does not include the design, installation and operation of a
complete robot application, nor does it include all peripheral equipment that may affect the safety
of the complete system. The design and use of the complete system need to comply with the
safety requirements established in the standards and regulations of the country where the robot is
installed. BUNKER integrators and end customers have the responsibility to ensure compliance
with the applicable laws and regulations of relevant countries, and to ensure that there are no
major dangers in the complete robot application. This includes but is not limited to the following:

Effectiveness and responsibility
● Make a risk assessment of the complete robot system. Connect the additional safety
  equipment of other machinery defined by the risk assessment together.
● Confirm that the design and installation of the entire robot system's peripheral equipment,
  including software and hardware systems, are correct.




                                               2 / 35
● This robot does not have a complete autonomous mobile robot, including but not limited to
  automatic anti-collision, anti-falling, biological approach warning and other related safety
  functions. Related functions require integrators and end customers to follow relevant
  regulations and feasible laws and regulations for safety assessment , To ensure that the
  developed robot does not have any major hazards and safety hazards in actual applications.
● Collect all the documents in the technical file: including risk assessment and this manual.
● Know the possible safety risks before operating and using the equipment.

Environmental Considerations
● For the first use,please read this manual carefully to understand the basic operating content
  and operating specification.
● For remote control operation, select a relatively open area to use Bunker, because Bunker is not
  equipped with any automatic obstacle avoidance sensor.
● Use Bunker always under -10℃~45℃ ambient temperature.
● If Bunker is not configured with separate custom IP protection, its water and dust protection will
  be IP44 ONLY.

Check
● Make sure each device has sufficient power.
● Make sure Bunker does not have any obvious defects.
● Check if the remote controller battery has sufficient power.
● When using, make sure the emergency stop switch has been released.




Precautions
Operation Precautions
● In remote control operation, make sure the area around is relatively spacious.
● Carry out remote control within the range of visibility.
● The maximum load of BUNKER is 70KG. When in use, ensure that the payload does not exceed
  70KG.
● When installing an external extension on BUNKER, confirm the position of the center of mass of
  the extension and make sure it is at the center of rotation.
● Please charge in time when the device voltage is lower than 48V.
● When BUNKER has a defect, please immediately stop using it to avoid secondary damage.



                                                 3 / 35
● When BUNKER has had a defect, please contact the relevant technical to deal with it, do not
  handle the defect by yourself.
● Always use BUNKER in the environment with the protection level requires for the equipment.
● Do not push BUNKER directly.
● When charging, make sure the ambient temperature is above 0℃.

Battery
● The battery of BUNKER products is not fully charged when it leaves the factory. The specific
  battery power can be read from the voltage display meter at the rear of the BUNKER chassis or
  the CAN bus communication interface;
● Please do not charge the battery after it is exhausted, and charge it in time when the low
  voltage at the tail of the BUNKER is lower than 48V;
● Static storage conditions: The optimal storage temperature is -10℃~45℃. When the battery is
  not in use, it must be charged and discharged once every month, and then stored at full
  voltage. Do not leave the battery in a Put into fire, or heat the battery, do not store the battery at
  high temperature;
● Charging: You must use the matching dedicated lithium battery charger for charging. Do not
  charge the battery below 0°C. Do not use non-original standard batteries, power supplies, and
  chargers.

Usage environment
● The working temperature of BUNKER is -10℃~45℃. Please do not use it in environments with
  temperatures below -10℃ and above 45℃;
● The relative humidity requirements of BUNKER's operating environment are: maximum 80%,
  minimum 30%;
● Do not use in an environment with corrosive or flammable gases or in an environment close to
  flammable substances;
● Do not exist around heating elements such as heaters or large winding resistors;
● Except for the specially customized version (customized with IP protection level), BUNKER is
  not waterproof, so please do not use it in environments with rain, snow, or standing water;
● It is recommended that the altitude of the operating environment does not exceed 1000M;
● It is recommended that the temperature difference between day and night in the use
  environment should not exceed 25°C;
● Regularly inspect and maintain the track tensioner.

Electrical external extension



                                                 4 / 35
● The current of the extended power supply at the tail does not exceed 6.25A, and the total
  power does not exceed 300W;

Additional safety advice
● If you have any questions about the use process, please follow the relevant instruction manual
  or consult relevant technical personnel;
● Before using the equipment, pay attention to the on-site conditions to avoid improper operation
  that may cause personal safety problems;
● In case of emergency, power off the device by tapping the emergency stop button;
● Please do not modify the internal device structure without technical support and permission.

Maintenance
● Regularly check the tension of the hanging crawler, and tighten the crawler every 150~200h.
● After every 500 hours of operation, the bolts and nuts of each part of the car body should be
  inspected. If they are loose, they must be tightened immediately.
● In order to ensure the storage capacity of the battery, the battery should be stored under
  electricity, and it should be charged regularly when not used for a long time.

Other notes
● When transporting and setting up, do not drop or turn it upside down;
● Non-professionals, please do not disassemble it without permission.




                                      CONTENTS




                                               5 / 35
                                             CONTENTS


Document version

Safety Information

Precautions

CONTENTS

1 BUNKER Introduction 

  1.1 Component list

  1.2 Tech specifications

  1.3 Required for development

2 The Basics

  2.1 Description of electrical interface

  2.2 Instructions on remote control

  2.3 Instructions on control demands and movements

3 Getting Started

  3.1 Use and operation

  3.2 Charging

  3.3 Communication using CAN 

    3.3.2 CAN Cable Connection

    3.3.3Implementation of CAN 

    3.4 Firmware upgrades

  3.5 BUNKER ROS Package Use Example

4 Q&A

5 Product Dimensions


  5.1 Product outline dimension illustration



                                               6 / 35
     5.2 Top expansion stent size description diagram




1 BUNKER Introduction
BUNKER is designed as a multi-purpose tracked chassis with different application scenarios
considered: simple and sensitive operation, large development space, adapt to various fields of
development and application, independent suspension system, high payload and suspension,
strong climbing ability, can climb stairs. It can be used for the development of special robots such
as inspection and exploration, rescue and detonation, special shooting, special transportation,
etc., to solve the robot mobile solution.


1.1 Component list

                       Name                                            Quantity

              BUNKER Robot Body                                           x1

            Battery Charger(AC 220V)                                      x1

                            ( )
              Aviation plug 4Pin                                          x1

     FS remote control transmitter(Optional)                              x1

                  USB to RS232                                            x1

      USB to CAN communication module                                     x1



1.2 Tech specifications

         Parameter Types                          Items                           Values

            Dimensions                         Dimensions                   1023*778*400mm




                                               7 / 35
                   Chassis height                  90mm

                     Track width                   150mm

                       Length                      560mm

                       Weight                   About 130kg
  Weight
                        Load                        70kg

                        Type                   Lithium battery

  Battery             Capacity                      30AH

                       Voltage                       48V

              Maximum climbing capacity              30°

                  Maximum Speed                    1.5m/s

               Minimum turning radius     Be able to turn on a pivot

                  Maximum obstacle                 170mm
Performance
                                          2×650W brushless servo
                  Motor parameters
                                                   motor

               Code wheel parameters             Line 1024

                Operating temperature             -10~45℃

                   Reduction ratio                  1:15

                                               Remote control
                    Control mode
                                          Command control mode

  Control                                  2.4G/extreme distance
                    RC transmitter
                                                    200m

               Communication interface              CAN




                      8 / 35
1.3 Required for development
FS RC transmitter is provided (optional) in the factory setting of BUNKER, which allows users to
control the chassis of robot to move and turn; CAN and RS232 interfaces on BUNKER can be
             ’
used for user s customization.




2 The Basics
This section provides a brief introduction to the BUNKER mobile robot platform. It is convenient
for users and developers to have a basic understanding of BUNKER chassis.


2.1 Description of electrical interface
The interface at rear end is shown in Figure 2-1, where Q1 is CAN and 48V power supply aviation
interface; Q2 is the power switch; Q3 is the recharging interface; Q4 is the aerial; Q5 is the drive
test interface; Q6 is the emergency stop switch; Q7 is the display of battery voltage.




                                  Figure 2.1 Tail electrical interface

The definitions of Q1 communication and power interface as shown in Figure 2-2.




                                                9 / 35
2.2 Instructions on remote control
FS RC transmitter is an optional accessory of BUNKER for manually controlling the robot. The
transmitter comes with a left-hand-throttle configuration. The functions of the buttons are defined
as: SWA, SWC, SWD are enabled by default. SWB for control mode selection, top position for
command control mode and the middle position for remote control mode. When configuring the
autowalker navigation system, the bottom is the navigation control mode. S1 is the throttle button
to control the forward and backward of BUNKER; S2 controls the rotation, POWER is the power
button, and it can be turned on at the same time. It should be noted that when the remote
controller is turned on, SWA, SWB, SWC, SWD all need to be at the top.




                                              10 / 35
                  Figure 2.3 Schematic Diagram of Buttons on FS RC transmitter

Remote control interface description:

Bunker : model

Vol: battery voltage

Car: chassis status

Batt: Chassis power percentage

P: Park

Remoter: remote control battery level

Fault Code: Error information (Represents byte [5] in 211 frame)




                                               11 / 35
2.3 Instructions on control demands and movements
A reference coordinate system can be defined and fixed on the vehicle body as shown in Figure
2.4 in accordance with ISO 8855.




As shown in Figure 2.4, the vehicle body of BUNKER is in parallel with X axis of the established
reference coordinate system.

In RC control mode, push the remote control stick S1 forward to move in the positive X direction,
push stick S1 backward to move in the negative X direction. When S1 is pushed to the maximum
value, the movement speed in the positive X direction is the maximum, when S1 is pushed to the
minimum value, the movement speed is the maximum in the negative direction of the X
direction.The remote control stick S2 controls the rotation of the car body left and right. The
remote control joystick S2 controls the rotation of the car body left and right. When S2 pushes the
car body to the left, it rotates from the positive direction of the X axis to the positive direction of
the Y axis. When S2 pushes the car body to the right, it rotates from the positive direction of the X
axis to the negative direction of the Y axis. S2 When pushing to the left to the maximum value, the
counterclockwise rotation speed is the maximum. When S2 is pushed to the right to the maximum
value, the clockwise rotation speed is the maximum.

Following this convention, a positive linear velocity corresponds to the forward movement of the
vehicle along positive x-axis direction and a positive angular velocity corresponds to positive right-
hand rotation about the z-axis.




                                                  12 / 35
3 Getting Started
   This section introduces the basic operation and development of the BUNKER platform using
the CAN bus interface.


3.1 Use and operation
Check
● Check the condition of vehicle body. Check whether there are significant anomalies; if so,
  please contact the after-sale service personnel for support;
● Check the state of emergency stop switches. Make sure Q6 emergency stop button at the rear
  is released;
● For first-time use, check whether Q3 (drive power supply switch) on the rear panel has been
  pressed down; if so, please release it, and then the drive will be powered off;

Startup
● Press the key switch (Q2 on the electrical panel), and normally, the voltmeter will display correct
  battery voltage and front and rear lights will be both switched on;
● Check the battery voltage. If the voltage is higher than 48V, it means the battery voltage is
  correct; if the battery power level is low, please charge the battery;

Shutdown
● Press the key switch to cut off the power supply;

Emergency stop
● Press down emergency push button at the rear of BUNKER vehicle body;

Basic operating procedure of remote control
● After the chassis of BUNKER mobile robot is started correctly, turn on the RC transmitter and
  select the remote-control mode. Then, BUNKER platform movement can be controlled by the
  RC transmitter.


3.2 Charging
BUNKER is equipped with a standard charger by default to meet customers' recharging demand.

The detailed operating procedure of charging is shown as follows:



                                                13 / 35
● Make sure the electricity of BUNKER chassis is powered off. Before charging, please make sure
  Q2 (key switch) in the rear control console is turned off;
● Insert the charger plug into Q3 charging interface on the rear control panel;
● Connect the charger to power supply and turn on the switch in the charger. Then, the robot
  enters the charging state.




3.3 Communication using CAN
BUNKER provides CAN interfaces for customization and development. Users can send command
to control the chassis through the CAN interface.

BUNKER uses CAN2.0B communication standard with 500K baud rate and Motorola message
format. The moving linear speed and the rotational angular speed of chassis can be controlled by
CAN bus interface. The feedback of current motion status and chassis status would be provided
from BUNKER simultaneously.

The protocol includes system status feedback frame, motion control feedback frame and control
frame, please refer to the content as below for detail:

The system status feedback command provides the feedback about current status of the chassis,
control mode status, battery voltage and system failure. The information is given in Table 3.1.

                         Table 3.1 Bunker Chassis Status Feedback Frame


    Command
                                           System Status Feedback Command
       Name

                                                                                      Receive-
   Sending node       Receiving node              ID              Cycle(ms)
                                                                                     timeout(ms)

   Steer-by-wire     Decision-making
                                                0x211              200ms                 None
      chassis           control unit

    Data length             0x08

      Position            Function            Data type                    Description




                                               14 / 35
                                                                      0x00 Normal condition
                  Current status of
byte [0]                                   unsigned int8              0x01 Emergency stop
                    vehicle body
                                                                       0x02 System Error

                                                                         0x00 Stand by

byte [1]            Mode control           unsigned int8         0x01 CAN command control

                                                                      0x03 Remote control

                  Battery voltage
byte [2]            upper 8 bits                                  Actual voltage × 10(with an
                                           unsigned int16
byte [3]          Battery voltage                                       accuracy of 0.1V)
                    lower 8 bits

byte [4]              Reserve                    -                            0x00

                       Failure                               Refer to Table3.2 Failure Information
byte [5]                                   unsigned int8
                    Information                                            Description

byte [6]              Reserve                    -                            0x00

                                                               0~255 Loops counting. Count is
                  Count Parity bit                                     incremented once
byte [7]                                   unsigned int8
                       (Count)                                 while single command sent every
                                                                              time


                         Table 3.2 Description of Failure Information


                                 Description of Failure Information

           Byte                                 Bit                            Meaning




                                              15 / 35
                                                  bit [0]                    Low-voltage failure




                                                 bit [1]                    Low-voltage warning

                                                                      Remote control signal lost
                                                 bit [2]             protection(0: Normal 1: Lost
              byte [5]
                                                                                   signal)

                                                                           Drive 1 communication
                                                 bit [3]
                                                                      failure(0: Normal 1: Failure)

                                                                           Drive 2 communication
                                                 bit [4]
                                                                      failure(0: Normal 1: Failure)

                                                 bit [5]                   Reserve, default value 0

                                                 bit [6]                   Reserve, default value 0

                                                 bit [7]                   Reserve, default value 0


The motion control feedback frame includes the feedback of linear and angular speed of chassis.
Please

refer to Table 3.3 for detail.

                                 Table 3.3 Motion Control Feedback Frame


                         Command Name        Movement Control Feedback Frame

                                                                                         Receive-
   Sending node          Receiving node            ID             Cycle(ms)
                                                                                       timeout(ms)

   Steer-by-wire         Decision-making
                                                 0x221              20ms                     None
       chassis             control unit




                                                 16 / 35
    Data length              0x08

      Position             Function         Data type                   Description

                        Moving speed
      byte [0]           upper 8 bits                          Actual speed X 1000 (with an
                                           signed int16
      byte [1]          Moving speed                              accuracy of 0.001m/s)
                          lower 8 bits

                        Rotation speed
      byte [2]           upper 8 bits                          Actual speed X 1000 (with an
                                           signed int16
      byte [3]          Rotation speed                           accuracy of 0.001rad/s)
                          lower 8 bits

      byte [4]             Reserved              -                         0x00

      byte [5]             Reserved              -                         0x00

      byte [6]             Reserved              -                         0x00

      byte [7]             Reserved              -                         0x00


The motion control frame includes linear speed, angular speed and checksum. Please refer to
Table 3.4 for detail.

                              Table 3.4 Motion Command Control Frame


 Command Name                                        Motion Command Control Frame

                                                                                   Receive-
   Sending node         Receiving node          ID             Cycle(ms)
                                                                                  timeout(ms)

 Decision-making
                         Chassis node         0x111              20ms                 500ms
    control unit

    Data length              0x08

      Position             Function         Data type                   Description




                                              17 / 35
                             Linear velocity
                                upper 8 byte
          byte [0]                                                       Linear moving speed mm/s(unit)
                                                  Signed int16
                                   Linear
          byte [1]                                                             Range[-1500,1500]
                             velocitylower 8
                                    byte

                                Linear speed                                 Rotation angular speed
          byte [2]              percentage
                                                  Signed int16                    0.001rad/s(unit)
          byte [3]           Angular speed
                                 percentage                                    Range [-1000,1000]


          byte [4]               Reserved                 —                            0x00

          byte [5]               Reserved                 —                            0x00

          byte [6]                Reserve                 —                            0x00

          byte [7]                Reserve                 —                            0x00


[Note] Sample data, the following data is only for testing. (You need to set the control mode to
command mode before testing)

1.The chassis moves forward at 0.15m/s.


   byte [0]          byte [1]       byte [2]   byte [3]       byte [4]    byte [5]     byte [6]      byte [7]

    0x00              0x96           0x00       0x00             0x00      0x00         0x00          0x00


2.The chassis steering 0.2rad


   byte [0]          byte [1]       byte [2]   byte [3]       byte [4]    byte [5]     byte [6]      byte [7]

    0x00              0x00           0x00       0x00             0x00      0x00         0x00          0xC8




The control mode setting frame is used to set the terminal interface. Please refer to Table 3.5 for
detail.




                                                       18 / 35
                                Table 3.5 Control Mode Setting Frame


 Command                                                   Control mode Frame


   Sending node        Receiving node              ID                     ( )
                                                                    Cycle ms
                                                                                           Receive-
                                                                                        timeout(ms)

 Decision-making
                       Chassis node              0x421                  20ms                 500m/s
    control unit

    Data length              0x01

      Location             Function            Data type                       Description

                      CAN Command                                 0x01 CAN Command mode 0x00
      byte [0]                               Unsigned int8
                           Mode                                                 Stand by


Note[1] Description for control mode

When the remote control is power off, the control mode of BUNKER is can command control by
default , that means chassis can be controlled by commands directly. Please note that the control
mode in command still need to set 0x01 if the speed command need to be executed successfully.
If you power on the remote control, then the remote control has the highest priority, the chassis
would switch the control mode based on remote control only.

The status clear frame is used to clear the system failures, please refer to table 3.6 for detail.

                                      Table 3.6 Status Clear Frame


    Command                                          Status Clear Frame


   Sending node        Receiving node              ID                    ( )
                                                                   Cycle ms
                                                                                           Receive-
                                                                                        timeout(ms)

      Key Unit         Chassis node                                    None                  None

    Data length              0x01                0x441

      Location             Function            Data type                       Description




                                                 19 / 35
                                                                         0x00 Clear all failures
                           Failures clear
      byte [0]                                   Unsigned int8         0x01 Clear motor1 failures
                            command
                                                                       0x02 Clear motor2 failures


In addition to the feedback of chassis status, there are also feedback data from the motors and
sensors.

                           Table 3.7 Motor Rotational Speed Feedback Frame


   Command Name             Motor Rotational Speed Feedback Frame

                                                                         Cycle            Receive-
    Sending node               Receiving node                 ID
                                                                        (ms)            timeout(ms)

   Decision-making
                               Chassis node           0x251~0x254        20ms               None
      control unit

      Data length                    0x08

       Position                    Function             Data type                       Description

                              Motor rotational
           byte[0]           speed upper 8bits                                        Motor rotational
                                                        signed int8
        byte[1]               Motor rotational                                           speed(RPM)
                              speed lower 8bits

    byte[2] -byte[7]               Reserve                    --                            0x00


                     Table 3.8 Motor Temperature, Voltage and Status Feedback Frame


   Command Name                                Motor Rotational Speed Feedback Frame


    Sending node             Receiving node              ID               ( )
                                                                      Cycle ms
                                                                                          Receive-
                                                                                        timeout(ms)

    Steer-by-wire           Decision-making
                                                    0x261-0x264         None                None
        chassis                 control unit




                                                    20 / 35
Data length         0x08

 Location         Function             Data type                  Description

 byte [0]         Reserved                      -                    0x00

 byte [1]         Reserved                      -                    0x00

                    Drive
                 temperature
 byte [2]        upper 8 bits
                                      Signed int 16                Unit: 1℃
 byte [3]           Drive
                 temperature
                 lower 8 bits

 byte [4]         Reserved                      -                    0x00

 byte [5]        Drive status        Unsigned int 8       Refer to Table 3.9 for detail

 byte [6]         Reserved                      -                    0x00

 byte [7]         Reserved                      -                    0x00


                            Table 3.9 Drive Status Byte


        Byte                            Bit                         Description


      byte [5]                                              Low-voltage (0: Normal 1:
                                      bit [0]
                                                                        Low)


                                                           Motor over- temperature (0:
                                      bit [1]
                                                           Normal 1: Over-temperature)

                                      bit [2]                        Reserved

                                      bit [3]                        Reserved

                                      bit [4]                        Reserved




                                      21 / 35
                                        bit [5]                       Reserved

                                        bit [6]                       Reserved

                                        bit [7]                       Reserved


                          Table 3.10 Odometer Feedback Frame


               Command Name                    Odometer Feedback Command


Sending node       Receiving node         ID                 ( )
                                                        Cycle ms
                                                                                Receive-
                                                                            timeout(ms)

Steer-by-wire     Decision-making
                                        0x311              20ms                  None
   chassis          control unit

 Data length           0x08

  Location            Function        Data type                   Description

                     Left wheel
                     odometer
                     highest bit

                     Left wheel
                     odometer
   byte [0]
                   second highest
   byte [1]              bit                          Left wheel odometer feedback (Unit:
                                     Signed int 32
   byte [2]          Left wheel                                      mm)

   byte [3]          odometer
                   second lowest
                        bit

                     Left wheel
                  odometer lowest
                         bit




                                       22 / 35
                  Right wheel
                   odometer
                   highest bit

                  Right wheel
                   odometer
   byte [4]     second highest
   byte [5]           bit                                Right wheel odometer feedback
                                       Signed int 32
   byte [6]       Right wheel                                       (Unit: mm)

   byte [7]        odometer
                 second lowest
                       bit

                  Right wheel
                odometer lowest
                       bit


                Table 3.11 Remote Control Information Feedback Frame


 Command
                                 Remote Control Information Feedback Command
    Name


Sending node    Receiving node              ID                ( )
                                                         Cycle ms
                                                                                 Receive-
                                                                             timeout(ms)

Steer-by-wire   Decision-making
                                          0x311             20ms                  None
   chassis        control unit

 Data length         0x08

  Location          Function             Data type                 Description




                                          23 / 35
                                                                 bit[0-1]: SWA   :2- Up 3-Down
                                                                bit[2-3]: SWB : 2-Up 1-Middle 3-
                                                                              Down
      byte [0]         SW feedback         Unsigned int8
                                                                bit[4-5]: SWC : 2-Up 1-Middle 3-
                                                                              Down

                                                                                 :
                                                                  bit[6-7]: SWD 2-Up 3-Down

                       Right joystick
      byte [1]                               Signed int8                Range[-100,100]
                        left and right

                     Right joystick up
      byte [2]                               Signed int8                Range[-100,100]
                        and down

                      Left joystick up
      byte [3]                               Signed int8                Range[-100,100]
                         and down

                      Left joystick left
      byte [4]                               Signed int8                Range[-100,100]
                          and right

      byte [5]        Left knob VRA          Singed int8                Range[-100,100]



3.3.2 CAN Cable Connection
BUNKER ships with the vehicle and provides a male aviation plug as shown in Figure 3.2. The
definition of the wires is: yellow is CANH, blue is CANL, red is the positive power supply, and black
is the negative power supply.

Note: In the current BUNKER version, only the tail interface is open to external expansion
interfaces. The power supply in this version can provide a maximum current of 10A.




                                               24 / 35
                                                                                  

                    Figure 3.2 Schematic diagram of aviation plug male connector




3.3.3 Implementation of CAN
Correctly start the chassis of BUNKER mobile robot, and turn on FS RC transmitter. Then, switch
to the command control mode, i.e. toggling SWB mode of FS RC transmitter to the top. At this
point, BUNKER chassis will accept the command from CAN interface, and the host can also parse
the current state of chassis with the real-time data fed back from CAN bus. For the detailed
content of protocol, please refer to CAN communication protocol.


3.4 Firmware upgrades
In order to facilitate users to upgrade the firmware version used by BUNKER and bring customers
a more complete experience, BUNKER provides a firmware upgrade hardware interface and
corresponding client software.



Upgrade Preparation
● Agilex CAN debugging module X 1
● Micro USB cable X 1
● BUNKER 2.0 chassis X 1
● A computer (WINDOWS OS (Operating System)) X 1




                                              25 / 35
Upgrade Process
1.Plug in the USBTOCAN module on the computer, and then open the
AgxCandoUpgradeToolV1.3_boxed.exe software (the sequence cannot be wrong, first open the
software and then plug in the module, the device will not be recognized).

2.Click the Open Serial button, and then press the power button on the car body. If the connection
is successful, the version information of the main control will be recognized, as shown in the figure.




3.Click the Load Firmware File button to load the firmware to be upgraded. If the loading is
successful, the firmware information will be obtained, as shown in the figure




                                               26 / 35
                                                                                           

4.Click the node to be upgraded in the node list box, and then click Start Upgrade Firmware to
start upgrading the firmware. After the upgrade is successful, a pop-up box will prompt.




                                                                                           




                                              27 / 35
3.5 BUNKER ROS Package Use Example
ROS provide some standard operating system services, such as hardware abstraction, low-level
device control, implementation of common function, interprocess message and data packet
management. ROS is based on a graph architecture, so that process of different nodes can
receive, and aggregate various information (such as sensing, control, status, planning, etc.)
Currently ROS mainly support UBUNTU.



Preparation
Hardware preparation

● CANlight can communication module ×1
● Thinkpad E470 notebook ×1
● AGILEX BUNKER mobile robot chassis ×1
● AGILEX BUNKER remote control FS-i6s ×1
● AGILEX BUNKER top aviation power socket ×1

Use example environment description

● Ubuntu 18.04




                                               28 / 35
● ROS melodic
● Git



Hardware connection and preparation
● Lead out the CAN wire of the BUNKER top aviation plug or the tail plug, and connect CAN_H
  and CAN_L in the CAN wire to the CAN_TO_USB adapter respectively;
● Turn on the knob switch on the BUNKER mobile robot chassis, and check whether the
  emergency stop switches on both sides are released          ;
● Connect the CAN_TO_USB to the usb point of the notebook. The connection diagram is shown
  in Figure 3.4.




                                  Figure 3.4 CAN connection diagram



ROS installation and environment setting
For installation details, please refer to

http://wiki.ros.org/kinetic/Installation/Ubuntu 



Test CANABLE hardware and CAN communication
Setting CAN-TO-USB adaptor

● Enable gs_usb kernel module


                                                                                    复制代码
 sudo modprobe gs_usb


● Setting 500k Baud rate and enable can-to-usb adaptor


                                                                                    复制代码
 sudo ip link set can0 up type can bitrate 500000



                                                    29 / 35
● If no error occurred in the previous steps, you should be able to use the command to view the
  can device immediately


                                                                                       复制代码
 ifconfig -a


● Install and use can-utils to test hardware


                                                                                       复制代码
 sudo apt install can-utils


● If the can-to-usb has been connected to the BUNKER robot this time, and the car has been
  turned on, use the following commands to monitor the data from the BUNKER chassis


                                                                                       复制代码
 candump can0


Please refer to:

[1] https://github.com/agilexrobotics/agx_sdk

[2] https://wi-ki.rdu.im/_pages/Notes/Embedded-System/Linux/-can-bus-in-linux.html 



AGILEX BUNKER ROS PACKAGE download and compile
● Download ros package


                                                                                       复制代码
 sudo apt install ros-$ROS_DISTRO-teleop-twist-keyboard
 sudo apt install ros-$ROS_DISTRO-joint-state-publisher-gui
 sudo apt install ros-$ROS_DISTRO-ros-controllers
 sudo apt install ros-$ROS_DISTRO-webots-ros
 sudo apt install libasio-dev




● Clone compile bunker_ros code


                                                                                       复制代码

                                                30 / 35
 cd ~/catkin_ws/src
 git clone https://github.com/agilexrobotics/bunker_ros.git
 git clone https://github.com/agilexrobotics/agx_sdk.git
 cd ~/catkin_ws
 catkin_make


Please refer to: https://github.com/agilexrobotics/bunker_ros 



Start the ROS node
● Start the based node


                                                                                         复制代码
 roslaunch bunker_bringup bunker_robot_base.launch


● Start the keyboard remote operation node


                                                                                         复制代码
 roslaunch bunker_bringup bunker_teleop_keyboard.launch


Github ROS development package directory and usage instructions

*_base:: The core node for the chassis to send and receive hierarchical CAN messages. Based on
the communication mechanism of ros, it can control the movement of the chassis and read the
status of the bunker through the topic.

*_msgs: Define the specific message format of the chassis status feedback topic.

*_bringup: startup files for chassis nodes and keyboard control nodes, and scripts to enable the
usb_to_can module



4 Q&A
 :
Q BUNKER is started up correctly, but why cannot the RC transmitter control the vehicle
body to move?

 :
A First, check whether the drive power supply is in normal condition, whether the drive power
switch is pressed down and whether E-stop switches are released; then, check whether the
control mode selected with the top left mode selection switch on the RC transmitter is correct.




                                              31 / 35
Q:BUNKER remote control is in normal condition, and the information about chassis status
and movement can be received correctly, but when the control frame protocol is issued,
why cannot the vehicle body control mode be switched and the chassis respond to the
control frame protocol?

A:Normally, if BUNKER can be controlled by a RC transmitter, it means the chassis movement is
under proper control; if the chassis feedback frame can be accepted, it means CAN extension link
is in normal condition. Please check the CAN control frame sent to see whether the data check is
correct and whether the control mode is in command control mode.



Q:When communication is implemented via CAN bus, the chassis feedback command is
issued correctly, but why does not the vehicle respond to the control command?

A:There is a communication protection mechanism inside BUNKER, which means the chassis is
provided with timeout protection when processing external CAN control commands. Suppose the
vehicle receives one frame of communication protocol, but it does no receive the next frame of
control command after 500ms. In this case, it will enter communication protection mode and set
the speed to 0. Therefore, commands from upper computer must be issued periodically.




5 Product Dimensions

5.1 Product outline dimension illustration




                                             32 / 35
5.2 Top expansion stent size description diagram




                             33 / 35
34 / 35
35 / 35


[READING ORDER TEXT]
1/35
 
BUNKER
AgileX Robotics Team
USER MANUAL V.2.0.0 2023.09
Document version
BUNKER USER MANUAL
No. Version Date
Edited
by
Reviewer Notes
1 V1.0.0 2023/03/17 谢瑞亲  Document creation2/35
Safety Information
This chapter contains important safety information, before the robot is powered on for he
first time, any individual or organization must read and understand this information before
using the device. If you have any questions about use, please contact us at
support@agilex.ai. Please follow and implement all assembly instructions and guidelines in
the chapters of this manual, which is very important. Particular attention should be paid to
the text related to the warning signs.
The information in this manual does not include the design, installation and operation of a
complete robot application, nor does it include all peripheral equipment that may affect the safety
of the complete system. The design and use of the complete system need to comply with the
safety requirements established in the standards and regulations of the country where the robot is
installed. BUNKER integrators and end customers have the responsibility to ensure compliance
with the applicable laws and regulations of relevant countries, and to ensure that there are no
major dangers in the complete robot application. This includes but is not limited to the following:
Effectiveness and responsibility
Make a risk assessment of the complete robot system. Connect the additional safety
equipment of other machinery defined by the risk assessment together.
Confirm that the design and installation of the entire robot system's peripheral equipment,
including software and hardware systems, are correct.
2 V2.0.0 2023/09/01 吴忠义 
Remote control data update
Synchronize the operation of
github official website
Bunker chassis firmware tutorial
Adjust document format
3 V2.0.1 2023/09/02 谢瑞亲 
Add rendering image
Document checking
●
●3/35
This robot does not have a complete autonomous mobile robot, including but not limited to
automatic anti-collision, anti-falling, biological approach warning and other related safety
functions. Related functions require integrators and end customers to follow relevant
regulations and feasible laws and regulations for safety assessment , To ensure that the
developed robot does not have any major hazards and safety hazards in actual applications.
Collect all the documents in the technical file: including risk assessment and this manual.
Know the possible safety risks before operating and using the equipment.
Environmental Considerations
For the first use,please read this manual carefully to understand the basic operating content
and operating specification.
For remote control operation, select a relatively open area to use Bunker, because Bunker is not
equipped with any automatic obstacle avoidance sensor.
Use Bunker always under -10℃~45℃ ambient temperature.
If Bunker is not configured with separate custom IP protection, its water and dust protection will
be IP44 ONLY.
Check
Make sure each device has sufficient power.
Make sure Bunker does not have any obvious defects.
Check if the remote controller battery has sufficient power.
When using, make sure the emergency stop switch has been released.
Precautions
Operation Precautions
In remote control operation, make sure the area around is relatively spacious.
Carry out remote control within the range of visibility.
The maximum load of BUNKER is 70KG. When in use, ensure that the payload does not exceed
70KG.
When installing an external extension on BUNKER, confirm the position of the center of mass of
the extension and make sure it is at the center of rotation.
Please charge in time when the device voltage is lower than 48V.
When BUNKER has a defect, please immediately stop using it to avoid secondary damage.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●4/35
When BUNKER has had a defect, please contact the relevant technical to deal with it, do not
handle the defect by yourself.
Always use BUNKER in the environment with the protection level requires for the equipment.
Do not push BUNKER directly.
When charging, make sure the ambient temperature is above 0℃.
Battery
The battery of BUNKER products is not fully charged when it leaves the factory. The specific
battery power can be read from the voltage display meter at the rear of the BUNKER chassis or
the CAN bus communication interface;
Please do not charge the battery after it is exhausted, and charge it in time when the low
voltage at the tail of the BUNKER is lower than 48V;
Static storage conditions: The optimal storage temperature is -10℃~45℃. When the battery is
not in use, it must be charged and discharged once every month, and then stored at full
voltage. Do not leave the battery in a Put into fire, or heat the battery, do not store the battery at
high temperature;
Charging: You must use the matching dedicated lithium battery charger for charging. Do not
charge the battery below 0°C. Do not use non-original standard batteries, power supplies, and
chargers.
Usage environment
The working temperature of BUNKER is -10℃~45℃. Please do not use it in environments with
temperatures below -10℃ and above 45℃;
The relative humidity requirements of BUNKER's operating environment are: maximum 80%,
minimum 30%;
Do not use in an environment with corrosive or flammable gases or in an environment close to
flammable substances;
Do not exist around heating elements such as heaters or large winding resistors;
Except for the specially customized version (customized with IP protection level), BUNKER is
not waterproof, so please do not use it in environments with rain, snow, or standing water;
It is recommended that the altitude of the operating environment does not exceed 1000M;
It is recommended that the temperature difference between day and night in the use
environment should not exceed 25°C;
Regularly inspect and maintain the track tensioner.
Electrical external extension
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●5/35
The current of the extended power supply at the tail does not exceed 6.25A, and the total
power does not exceed 300W;
Additional safety advice
If you have any questions about the use process, please follow the relevant instruction manual
or consult relevant technical personnel;
Before using the equipment, pay attention to the on-site conditions to avoid improper operation
that may cause personal safety problems;
In case of emergency, power off the device by tapping the emergency stop button;
Please do not modify the internal device structure without technical support and permission.
Maintenance
Regularly check the tension of the hanging crawler, and tighten the crawler every 150~200h.
After every 500 hours of operation, the bolts and nuts of each part of the car body should be
inspected. If they are loose, they must be tightened immediately.
In order to ensure the storage capacity of the battery, the battery should be stored under
electricity, and it should be charged regularly when not used for a long time.
Other notes
When transporting and setting up, do not drop or turn it upside down;
Non-professionals, please do not disassemble it without permission.
CONTENTS
●
●
●
●
●
●
●
●
●
●6/35
CONTENTS
Document version  
Safety Information  
Precautions  
CONTENTS  
1 BUNKER Introduction   
1.1 Component list  
1.2 Tech specifications  
1.3 Required for development  
2 The Basics  
2.1 Description of electrical interface  
2.2 Instructions on remote control
2.3 Instructions on control demands and movements  
3 Getting Started  
3.1 Use and operation  
3.2 Charging  
3.3 Communication using CAN   
3.3.2 CAN Cable Connection  
3.3.3Implementation of CAN   
3.4 Firmware upgrades  
3.5 BUNKER ROS Package Use Example  
4 Q&A  
5 Product Dimensions
5.1 Product outline dimension illustration  7/35
1 BUNKER Introduction
BUNKER is designed as a multi-purpose tracked chassis with different application scenarios
considered: simple and sensitive operation, large development space, adapt to various fields of
development and application, independent suspension system, high payload and suspension,
strong climbing ability, can climb stairs. It can be used for the development of special robots such
as inspection and exploration, rescue and detonation, special shooting, special transportation,
etc., to solve the robot mobile solution.
1.1 Component list
1.2 Tech specifications
5.2 Top expansion stent size description diagram  
Name Quantity
BUNKER Robot Body x1
Battery Charger(AC 220V) x1
Aviation plug(4Pin) x1
FS remote control transmitter(Optional) x1
USB to RS232 x1
USB to CAN communication module x1
Parameter Types Items Values
Dimensions Dimensions 1023*778*400mm8/35
Chassis height 90mm
Track width 150mm
Length 560mm
Weight
Weight About 130kg
Load 70kg
Battery
Type Lithium battery
Capacity 30AH
Voltage 48V
Performance
Maximum climbing capacity 30°
Maximum Speed 1.5m/s
Minimum turning radius Be able to turn on a pivot
Maximum obstacle 170mm
Motor parameters
2×650W brushless servo
motor
Code wheel parameters Line 1024
Operating temperature -10~45℃
Reduction ratio 1:15
Control
Control mode
Remote control
Command control mode
RC transmitter
2.4G/extreme distance
200m
Communication interface CAN9/35
1.3 Required for development
FS RC transmitter is provided (optional) in the factory setting of BUNKER, which allows users to
control the chassis of robot to move and turn; CAN and RS232 interfaces on BUNKER can be
used for user’s customization.
2 The Basics
This section provides a brief introduction to the BUNKER mobile robot platform. It is convenient
for users and developers to have a basic understanding of BUNKER chassis.
2.1 Description of electrical interface
The interface at rear end is shown in Figure 2-1, where Q1 is CAN and 48V power supply aviation
interface; Q2 is the power switch; Q3 is the recharging interface; Q4 is the aerial; Q5 is the drive
test interface; Q6 is the emergency stop switch; Q7 is the display of battery voltage.
Figure 2.1 Tail electrical interface
The definitions of Q1 communication and power interface as shown in Figure 2-2.10/35
2.2 Instructions on remote control
FS RC transmitter is an optional accessory of BUNKER for manually controlling the robot. The
transmitter comes with a left-hand-throttle configuration. The functions of the buttons are defined
as: SWA, SWC, SWD are enabled by default. SWB for control mode selection, top position for
command control mode and the middle position for remote control mode. When configuring the
autowalker navigation system, the bottom is the navigation control mode. S1 is the throttle button
to control the forward and backward of BUNKER; S2 controls the rotation, POWER is the power
button, and it can be turned on at the same time. It should be noted that when the remote
controller is turned on, SWA, SWB, SWC, SWD all need to be at the top.11/35
Figure 2.3 Schematic Diagram of Buttons on FS RC transmitter
Remote control interface description:
Bunker : model
Vol: battery voltage
Car: chassis status
Batt: Chassis power percentage
P: Park
Remoter: remote control battery level
Fault Code: Error information (Represents byte [5] in 211 frame)12/35
2.3 Instructions on control demands and movements
A reference coordinate system can be defined and fixed on the vehicle body as shown in Figure
2.4 in accordance with ISO 8855.
As shown in Figure 2.4, the vehicle body of BUNKER is in parallel with X axis of the established
reference coordinate system.
In RC control mode, push the remote control stick S1 forward to move in the positive X direction,
push stick S1 backward to move in the negative X direction. When S1 is pushed to the maximum
value, the movement speed in the positive X direction is the maximum, when S1 is pushed to the
minimum value, the movement speed is the maximum in the negative direction of the X
direction.The remote control stick S2 controls the rotation of the car body left and right. The
remote control joystick S2 controls the rotation of the car body left and right. When S2 pushes the
car body to the left, it rotates from the positive direction of the X axis to the positive direction of
the Y axis. When S2 pushes the car body to the right, it rotates from the positive direction of the X
axis to the negative direction of the Y axis. S2 When pushing to the left to the maximum value, the
counterclockwise rotation speed is the maximum. When S2 is pushed to the right to the maximum
value, the clockwise rotation speed is the maximum.
Following this convention, a positive linear velocity corresponds to the forward movement of the
vehicle along positive x-axis direction and a positive angular velocity corresponds to positive right-
hand rotation about the z-axis.13/35
3 Getting Started
This section introduces the basic operation and development of the BUNKER platform using
the CAN bus interface.
3.1 Use and operation
Check
Check the condition of vehicle body. Check whether there are significant anomalies; if so,
please contact the after-sale service personnel for support;
Check the state of emergency stop switches. Make sure Q6 emergency stop button at the rear
is released;
For first-time use, check whether Q3 (drive power supply switch) on the rear panel has been
pressed down; if so, please release it, and then the drive will be powered off;
Startup
Press the key switch (Q2 on the electrical panel), and normally, the voltmeter will display correct
battery voltage and front and rear lights will be both switched on;
Check the battery voltage. If the voltage is higher than 48V, it means the battery voltage is
correct; if the battery power level is low, please charge the battery;
Shutdown
Press the key switch to cut off the power supply;
Emergency stop
Press down emergency push button at the rear of BUNKER vehicle body;
Basic operating procedure of remote control
After the chassis of BUNKER mobile robot is started correctly, turn on the RC transmitter and
select the remote-control mode. Then, BUNKER platform movement can be controlled by the
RC transmitter.
3.2 Charging
BUNKER is equipped with a standard charger by default to meet customers' recharging demand.
The detailed operating procedure of charging is shown as follows:
●
●
●
●
●
●
●
●14/35
Make sure the electricity of BUNKER chassis is powered off. Before charging, please make sure
Q2 (key switch) in the rear control console is turned off;
Insert the charger plug into Q3 charging interface on the rear control panel;
Connect the charger to power supply and turn on the switch in the charger. Then, the robot
enters the charging state.
3.3 Communication using CAN
BUNKER provides CAN interfaces for customization and development. Users can send command
to control the chassis through the CAN interface.
BUNKER uses CAN2.0B communication standard with 500K baud rate and Motorola message
format. The moving linear speed and the rotational angular speed of chassis can be controlled by
CAN bus interface. The feedback of current motion status and chassis status would be provided
from BUNKER simultaneously.
The protocol includes system status feedback frame, motion control feedback frame and control
frame, please refer to the content as below for detail:
The system status feedback command provides the feedback about current status of the chassis,
control mode status, battery voltage and system failure. The information is given in Table 3.1.
Table 3.1 Bunker Chassis Status Feedback Frame
●
●
●
Command
Name
System Status Feedback Command
Sending node Receiving node ID Cycle(ms)
Receive-
timeout(ms)
Steer-by-wire
chassis
Decision-making
control unit
0x211 200ms None
Data length 0x08
Position Function Data type Description15/35
Table 3.2 Description of Failure Information
byte [0]
Current status of
vehicle body
unsigned int8
0x00 Normal condition
0x01 Emergency stop
0x02 System Error
byte [1] Mode control unsigned int8
0x00 Stand by
0x01 CAN command control
0x03 Remote control
byte [2]
byte [3]
Battery voltage
upper 8 bits
Battery voltage
lower 8 bits
unsigned int16
Actual voltage × 10(with an
accuracy of 0.1V)
byte [4] Reserve - 0x00
byte [5]
Failure
Information
unsigned int8
Refer to Table3.2 Failure Information
Description
byte [6] Reserve - 0x00
byte [7]
Count Parity bit
(Count)
unsigned int8
0~255 Loops counting. Count is
incremented once
while single command sent every
time
Description of Failure Information
Byte Bit Meaning16/35
The motion control feedback frame includes the feedback of linear and angular speed of chassis.
Please
refer to Table 3.3 for detail.
Table 3.3 Motion Control Feedback Frame
byte [5]
bit [0] Low-voltage failure
bit [1] Low-voltage warning
bit [2]
Remote control signal lost
protection(0: Normal 1: Lost
signal)
bit [3]
Drive 1 communication
failure(0: Normal 1: Failure)
bit [4]
Drive 2 communication
failure(0: Normal 1: Failure)
bit [5] Reserve, default value 0
bit [6] Reserve, default value 0
bit [7] Reserve, default value 0
Command Name Movement Control Feedback Frame
Sending node Receiving node ID Cycle(ms)
Receive-
timeout(ms)
Steer-by-wire
chassis
Decision-making
control unit
0x221 20ms None17/35
The motion control frame includes linear speed, angular speed and checksum. Please refer to
Table 3.4 for detail.
Table 3.4 Motion Command Control Frame
Data length 0x08
Position Function Data type Description
byte [0]
byte [1]
Moving speed
upper 8 bits
Moving speed
lower 8 bits
signed int16
Actual speed X 1000 (with an
accuracy of 0.001m/s)
byte [2]
byte [3]
Rotation speed
upper 8 bits
Rotation speed
lower 8 bits
signed int16
Actual speed X 1000 (with an
accuracy of 0.001rad/s)
byte [4] Reserved - 0x00
byte [5] Reserved - 0x00
byte [6] Reserved - 0x00
byte [7] Reserved - 0x00
Command Name Motion Command Control Frame
Sending node Receiving node ID Cycle(ms)
Receive-
timeout(ms)
Decision-making
control unit
Chassis node 0x111 20ms 500ms
Data length 0x08
Position Function Data type Description18/35
[Note] Sample data, the following data is only for testing. (You need to set the control mode to
command mode before testing)
1.The chassis moves forward at 0.15m/s.
2.The chassis steering 0.2rad
The control mode setting frame is used to set the terminal interface. Please refer to Table 3.5 for
detail.
byte [0]
byte [1]
Linear velocity
upper 8 byte
Linear
velocitylower 8
byte
Signed int16
Linear moving speed mm/s(unit)
Range[-1500,1500]
byte [2]
byte [3]
Linear speed
percentage
Angular speed
percentage
Signed int16
Rotation angular speed
0.001rad/s(unit)
Range [-1000,1000]
byte [4] Reserved — 0x00
byte [5] Reserved — 0x00
byte [6] Reserve — 0x00
byte [7] Reserve — 0x00
byte [0] byte [1] byte [2] byte [3] byte [4] byte [5] byte [6] byte [7]
0x00 0x96 0x00 0x00 0x00 0x00 0x00 0x00
byte [0] byte [1] byte [2] byte [3] byte [4] byte [5] byte [6] byte [7]
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xC819/35
Table 3.5 Control Mode Setting Frame
Note[1] Description for control mode
When the remote control is power off, the control mode of BUNKER is can command control by
default , that means chassis can be controlled by commands directly. Please note that the control
mode in command still need to set 0x01 if the speed command need to be executed successfully.
If you power on the remote control, then the remote control has the highest priority, the chassis
would switch the control mode based on remote control only.
The status clear frame is used to clear the system failures, please refer to table 3.6 for detail.
Table 3.6 Status Clear Frame
Command Control mode Frame
Sending node Receiving node ID Cycle(ms) Receive-
timeout(ms)
Decision-making
control unit
Chassis node 0x421 20ms 500m/s
Data length 0x01
Location Function Data type Description
byte [0]
CAN Command
Mode
Unsigned int8
0x01 CAN Command mode 0x00
Stand by
Command Status Clear Frame
Sending node Receiving node ID Cycle(ms) Receive-
timeout(ms)
Key Unit Chassis node None None
Data length 0x01 0x441
Location Function Data type Description20/35
In addition to the feedback of chassis status, there are also feedback data from the motors and
sensors.
Table 3.7 Motor Rotational Speed Feedback Frame
Table 3.8 Motor Temperature, Voltage and Status Feedback Frame
byte [0]
Failures clear
command
Unsigned int8
0x00 Clear all failures
0x01 Clear motor1 failures
0x02 Clear motor2 failures
Command Name Motor Rotational Speed Feedback Frame
Sending node Receiving node ID
Cycle
(ms)
Receive-
timeout(ms)
Decision-making
control unit
Chassis node 0x251~0x254 20ms None
Data length 0x08
Position Function Data type Description
byte[0]
byte[1]
Motor rotational
speed upper 8bits
Motor rotational
speed lower 8bits
signed int8
Motor rotational
speed(RPM)
byte[2] -byte[7] Reserve -- 0x00
Command Name Motor Rotational Speed Feedback Frame
Sending node Receiving node ID Cycle(ms) Receive-
timeout(ms)
Steer-by-wire
chassis
Decision-making
control unit
0x261-0x264 None None21/35
Table 3.9 Drive Status Byte
Data length 0x08
Location Function Data type Description
byte [0]
byte [1]
Reserved
Reserved
-
-
0x00
0x00
byte [2]
byte [3]
Drive
temperature
upper 8 bits
Drive
temperature
lower 8 bits
Signed int 16 Unit: 1℃
byte [4] Reserved - 0x00
byte [5] Drive status Unsigned int 8 Refer to Table 3.9 for detail
byte [6] Reserved - 0x00
byte [7] Reserved - 0x00
Byte Bit Description
byte [5]
bit [0]
Low-voltage (0: Normal 1:
Low)
bit [1]
Motor over- temperature (0:
Normal 1: Over-temperature)
bit [2] Reserved
bit [3] Reserved
bit [4] Reserved22/35
Table 3.10 Odometer Feedback Frame
bit [5] Reserved
bit [6] Reserved
bit [7] Reserved
Command Name Odometer Feedback Command
Sending node Receiving node ID Cycle(ms) Receive-
timeout(ms)
Steer-by-wire
chassis
Decision-making
control unit
0x311 20ms None
Data length 0x08
Location Function Data type Description
byte [0]
byte [1]
byte [2]
byte [3]
Left wheel
odometer
highest bit
Left wheel
odometer
second highest
bit
Left wheel
odometer
second lowest
bit
Left wheel
odometer lowest
bit
Signed int 32
Left wheel odometer feedback (Unit:
mm)23/35
Table 3.11 Remote Control Information Feedback Frame
byte [4]
byte [5]
byte [6]
byte [7]
Right wheel
odometer
highest bit
Right wheel
odometer
second highest
bit
Right wheel
odometer
second lowest
bit
Right wheel
odometer lowest
bit
Signed int 32
Right wheel odometer feedback
(Unit: mm)
Command
Name
Remote Control Information Feedback Command
Sending node Receiving node ID Cycle(ms) Receive-
timeout(ms)
Steer-by-wire
chassis
Decision-making
control unit
0x311 20ms None
Data length 0x08
Location Function Data type Description24/35
3.3.2 CAN Cable Connection
BUNKER ships with the vehicle and provides a male aviation plug as shown in Figure 3.2. The
definition of the wires is: yellow is CANH, blue is CANL, red is the positive power supply, and black
is the negative power supply.
Note: In the current BUNKER version, only the tail interface is open to external expansion
interfaces. The power supply in this version can provide a maximum current of 10A.
byte [0] SW feedback Unsigned int8
bit[0-1]: SWA :2- Up 3-Down
bit[2-3]: SWB : 2-Up 1-Middle 3-
Down
bit[4-5]: SWC : 2-Up 1-Middle 3-
Down
bit[6-7]: SWD:2-Up 3-Down
byte [1]
Right joystick
left and right
Signed int8 Range[-100,100]
byte [2]
Right joystick up
and down
Signed int8 Range[-100,100]
byte [3]
Left joystick up
and down
Signed int8 Range[-100,100]
byte [4]
Left joystick left
and right
Signed int8 Range[-100,100]
byte [5] Left knob VRA Singed int8 Range[-100,100]25/35
 
Figure 3.2 Schematic diagram of aviation plug male connector
3.3.3 Implementation of CAN
Correctly start the chassis of BUNKER mobile robot, and turn on FS RC transmitter. Then, switch
to the command control mode, i.e. toggling SWB mode of FS RC transmitter to the top. At this
point, BUNKER chassis will accept the command from CAN interface, and the host can also parse
the current state of chassis with the real-time data fed back from CAN bus. For the detailed
content of protocol, please refer to CAN communication protocol.
3.4 Firmware upgrades
In order to facilitate users to upgrade the firmware version used by BUNKER and bring customers
a more complete experience, BUNKER provides a firmware upgrade hardware interface and
corresponding client software.
Upgrade Preparation
Agilex CAN debugging module X 1
Micro USB cable X 1
BUNKER 2.0 chassis X 1
A computer (WINDOWS OS (Operating System)) X 1
●
●
●
●26/35
Upgrade Process
1.Plug in the USBTOCAN module on the computer, and then open the
AgxCandoUpgradeToolV1.3_boxed.exe software (the sequence cannot be wrong, first open the
software and then plug in the module, the device will not be recognized).
2.Click the Open Serial button, and then press the power button on the car body. If the connection
is successful, the version information of the main control will be recognized, as shown in the figure.
3.Click the Load Firmware File button to load the firmware to be upgraded. If the loading is
successful, the firmware information will be obtained, as shown in the figure27/35

4.Click the node to be upgraded in the node list box, and then click Start Upgrade Firmware to
start upgrading the firmware. After the upgrade is successful, a pop-up box will prompt.
28/35
3.5 BUNKER ROS Package Use Example
ROS provide some standard operating system services, such as hardware abstraction, low-level
device control, implementation of common function, interprocess message and data packet
management. ROS is based on a graph architecture, so that process of different nodes can
receive, and aggregate various information (such as sensing, control, status, planning, etc.)
Currently ROS mainly support UBUNTU.
Preparation
Hardware preparation
CANlight can communication module ×1
Thinkpad E470 notebook ×1
AGILEX BUNKER mobile robot chassis ×1
AGILEX BUNKER remote control FS-i6s ×1
AGILEX BUNKER top aviation power socket ×1
Use example environment description
Ubuntu 18.04
●
●
●
●
●
●29/35
ROS melodic
Git
Hardware connection and preparation
Lead out the CAN wire of the BUNKER top aviation plug or the tail plug, and connect CAN_H
and CAN_L in the CAN wire to the CAN_TO_USB adapter respectively;
Turn on the knob switch on the BUNKER mobile robot chassis, and check whether the
emergency stop switches on both sides are released;
Connect the CAN_TO_USB to the usb point of the notebook. The connection diagram is shown
in Figure 3.4.
Figure 3.4 CAN connection diagram
ROS installation and environment setting
For installation details, please refer to
http://wiki.ros.org/kinetic/Installation/Ubuntu
Test CANABLE hardware and CAN communication
Setting CAN-TO-USB adaptor
Enable gs_usb kernel module
复制代码
Setting 500k Baud rate and enable can-to-usb adaptor
复制代码
●
●
●
●
●
●
sudo modprobe gs_usb
●
sudo ip link set can0 up type can bitrate 50000030/35
If no error occurred in the previous steps, you should be able to use the command to view the
can device immediately
复制代码
Install and use can-utils to test hardware
复制代码
If the can-to-usb has been connected to the BUNKER robot this time, and the car has been
turned on, use the following commands to monitor the data from the BUNKER chassis
复制代码
Please refer to:
[1]https://github.com/agilexrobotics/agx_sdk
[2]https://wi-ki.rdu.im/_pages/Notes/Embedded-System/Linux/-can-bus-in-linux.html
AGILEX BUNKER ROS PACKAGE download and compile
Download ros package
复制代码
Clone compile bunker_ros code
复制代码
●
ifconfig -a
●
sudo apt install can-utils
●
candump can0
●
sudo apt install ros-$ROS_DISTRO-teleop-twist-keyboard
sudo apt install ros-$ROS_DISTRO-joint-state-publisher-gui
sudo apt install ros-$ROS_DISTRO-ros-controllers
sudo apt install ros-$ROS_DISTRO-webots-ros
sudo apt install libasio-dev
●31/35
Please refer to: https://github.com/agilexrobotics/bunker_ros
Start the ROS node
Start the based node
复制代码
Start the keyboard remote operation node
复制代码
Github ROS development package directory and usage instructions
*_base:: The core node for the chassis to send and receive hierarchical CAN messages. Based on
the communication mechanism of ros, it can control the movement of the chassis and read the
status of the bunker through the topic.
*_msgs: Define the specific message format of the chassis status feedback topic.
*_bringup: startup files for chassis nodes and keyboard control nodes, and scripts to enable the
usb_to_can module
4 Q&A
Q:BUNKER is started up correctly, but why cannot the RC transmitter control the vehicle
body to move?
A:First, check whether the drive power supply is in normal condition, whether the drive power
switch is pressed down and whether E-stop switches are released; then, check whether the
control mode selected with the top left mode selection switch on the RC transmitter is correct.
cd ~/catkin_ws/src
git clone https://github.com/agilexrobotics/bunker_ros.git
git clone https://github.com/agilexrobotics/agx_sdk.git
cd ~/catkin_ws
catkin_make
●
roslaunch bunker_bringup bunker_robot_base.launch
●
roslaunch bunker_bringup bunker_teleop_keyboard.launch32/35
Q:BUNKER remote control is in normal condition, and the information about chassis status
and movement can be received correctly, but when the control frame protocol is issued,
why cannot the vehicle body control mode be switched and the chassis respond to the
control frame protocol?
A:Normally, if BUNKER can be controlled by a RC transmitter, it means the chassis movement is
under proper control; if the chassis feedback frame can be accepted, it means CAN extension link
is in normal condition. Please check the CAN control frame sent to see whether the data check is
correct and whether the control mode is in command control mode.
Q:When communication is implemented via CAN bus, the chassis feedback command is
issued correctly, but why does not the vehicle respond to the control command?
A:There is a communication protection mechanism inside BUNKER, which means the chassis is
provided with timeout protection when processing external CAN control commands. Suppose the
vehicle receives one frame of communication protocol, but it does no receive the next frame of
control command after 500ms. In this case, it will enter communication protection mode and set
the speed to 0. Therefore, commands from upper computer must be issued periodically.
5 Product Dimensions
5.1 Product outline dimension illustration33/35
5.2 Top expansion stent size description diagram34/3535/35