ZDROJOVÝ PODKLAD
Uložený text
https://indrorobotics.ca/wp-content/uploads/2024/07/TITAN-User-Manual.pdf ↗TITAN User Manual
TITAN
AgileX Robotics Team
用户手册 V.2.0.1 2023.08
Document version
No. Version Date Edited by Reviewer Notes
1 V1.0.0 2022/10/15 何士玉 first draft
Update
2 V2.0.0 2023/3/23 李圣望、何士玉 agreement
content
1 / 49
3 V2.0.1 2023/09/02 谢瑞亲
Before using the robot, any individual or organization must read and understand the manual. If
you have any questions about it, please do not hesitate to contact us at support@agilex.ai . It is
very important that you should follow and implement all instructions and guidelines in this
manual. Please pay extra attention to the warnings.
Important Safety Information
This manual does not cover the design, installation, and operation of a robotic application, nor
does it include any equipment that may affect the safety of a robotic system. A robot system
that uses the TITAN should be designed and used in compliance with the safety requirements
and other standards of the corresponding countries.
Any users of the TITAN should comply with laws and regulations of relevant countries and
ensure that there are no obvious hazards in the application of the TITAN. This includes but is
not limited to the following:
Responsibility
Do a risk assessment of the robotic system that uses the TITAN.
The risk assessment should include additional safety equipment to other machinery.
Please ensure that the equipment of the whole robotic system, including software and hardware,
are designed, and installed correctly.
The TITAN is not an autonomous mobile robot with anti-collision, anti-fall, biological
approach warning, and other safety functions. These safety functions are expected to be
developed and assessed by system integrators and end customers under relevant safety
regulations and laws to ensure there are not any major dangers and potential safety hazards in
their practical applications.
2 / 49
Read all technical documents: including the risk assessment and this manual.
Know the possible safety risks before using the TITAN.
Use Environment
For the first use, please read this manual carefully to understand the basic operation and
operating specifications.
Remote control operation should be in a relatively open area. The TITAN does not have any
automatic obstacle avoidance sensors.
Please use the TITAN under the ambient temperature of 0 ℃~ 40 ℃.
’
The TITAN s waterproof and dustproof level is IP22 if it is not customized
Check
Make sure each device is fully charged.
Make sure the TITAN has no obvious abnormalities.
Make sure the remote control has sufficient battery power
Operation Precautions
Ensure that the surrounding area is relatively open when operating the TITAN.
Please do remote control within sight.
The maximum load of the TITAN is 150 KG. Please ensure that the payload does not exceed
150 KG when using.
When installing external equipment on the TITAN, Please ensure their centroid location is at
’
the TITAN s center of rotation.
Please charge the TITAN in time after low-battery alarm.
When the TITAN is abnormal, please stop using it immediately to avoid secondary injury.
When the TITAN is abnormal, please contact the technical support immediately, and do not
handle it without professional suggestion.
3 / 49
Please use the TITAN in an environment that does not exceed its IP protection level.
Do not push the TITAN directly.
Tail extension power supply current does not exceed 15A, total power does not exceed 720W
Battery Precautions
The batteries of TITAN products are not fully charged when they leave the factory. The specific
battery voltage and power can be displayed through the voltage indicator at the rear of the TITAN
chassis or through the vol and batt on the remote control.
Please do not charge the battery after it is exhausted. Please charge it in time when the low
battery of the TITAN remote control is lower than 15% or the tail voltage display is lower
than 25V.
Static storage conditions: The best temperature for storage is -10°C~40°C. When the battery is
not in use, it must be charged and discharged once a month, and then stored at full voltage. Do
not leave the battery Put it in fire, or heat the battery, do not store the battery at high temperature.
Charging: You must use the matching lithium battery charger for charging. Do not charge the
battery below 0°C. Do not use non-original standard batteries, power supplies, and chargers.
Precautions for use environment
The operating temperature of TITAN is -10°C~40°C, please do not use it in an environment where
the temperature is lower than -10°C and higher than 40°C
Do not use in environments with corrosive or flammable gases or near flammable substances
Please do not use it around heating elements such as heaters or large winding resistors
The waterproof and dustproof grade of TITAN is IP22, please pay attention to the use environment,
check and remove rust regularly
It is recommended that the altitude of the use environment should not exceed 1000M
It is recommended that the ambient temperature difference between day and night does not
exceed 25°C
Regular inspection and maintenance of track tensioning wheels
Safety Precautions
4 / 49
If you have any questions about the use process, please follow the relevant instruction manual or
consult relevant technical personnel
Before using the equipment to operate, pay attention to the situation on site to avoid personnel
safety problems caused by misoperation
In case of emergency, power off the device by tapping the emergency stop button
Do not modify the internal equipment structure without technical support and permission
When the equipment is abnormal, please stop using it immediately to avoid secondary injury
When the device is abnormal, please contact the relevant technical personnel, and do not handle
it without authorization.
CONTENTS
5 / 49
CONTENTS
Document version
Important Safety Information
CONTENTS
1 Introduction to TITAN
1.1 Specifications
1.2 Required for Development
2 Basic Introduction
2.1 Status of the TITAN
2.2 Description of Electrical Interfaces
2.3 Remote Control Instructions
3 Usage and Development
3.1 Operation
3.2 CAN Communication Protocol
3.3 TITAN use manual for ROS
3.4 The Github ROS development kit and user manual
3.5 Firmware Upgrade
3.6 The vehicle body coordinate system
4 Maintenance Instructions
4.1 Maintenance method
5 Product Size
1 Introduction to TITAN
6 / 49
TITAN is a programmable front and rear dual-steering UGV (UNMANNED GROUND VEHICLE),
which is a chassis with a modular design. Compared with the former AKM chassis, TITAN not only
greatly reduces the turning radius, but also is more stable and safer. have wider applications.
TITAN chassis, suitable for a variety of complex terrain. At the same time, it can be equipped with
stereo cameras, lidar, GPS, IMU, manipulators and other equipment, and is applied to unmanned
inspection, security, scientific research, exploration and logistics and other fields.
1.1 Specifications
Type Description Parameters
Dimensions (mm) 1640×980×1440
Axle Track(mm) 860
Mechanical Wheel Base(mm) 845
Rated power (w) 1000
Rated torque (N.M) 556
Maximum Speed m/s ( ) 10.8
Performance
Motion Mode Front and rear Ackermann
Maximum Obstacle Height (
100 vertical obstacles
(mm) and fully loaded )
Maximum Climbing Angle
(°) 10
Weight(kg) 280(two batteries)
Maximum Load (kg) 300
Battery Life (h) >5h(1.4km/h test)
Charging efficiency 1C
7 / 49
Lithium iron phosphate
Battery Type
battery
( ) (
24 Can support up to 2
Single Battery Capacity ah
batteries)
Rated Voltage v () 48
Engineering Investigation
Energy Inspection
Mine Transportation
Functional Application
Intelligent Security
Logistics
Agricultural Product
Collection and Transportation
1.2 Required for Development
TITAN can be equipped with FS remote control when it leaves the factory. Users can control the
chassis through the remote control to complete mode switching, movement and steering control.
TITAN is equipped with a standard CAN communication interface, and users can carry out
secondary development through the CAN interface.
2 Basic Introduction
This part is a basic introduction to the TITAN, mobile robot chassis. After reading this part, users
and developers can have an overall understanding about it. As shown in Figure 2.1 below, it is an
overview of the TITAN.
8 / 49
Figure 2.1 Overview of the TITAN
TITAN adopts a modular and intelligent design concept as a whole. It adopts a pneumatic tire
design on the power module, coupled with a powerful permanent magnet synchronous motor,
which makes the TITAN robot chassis have a strong battery life and load capacity. The motor with
a power of 1000W enables TITAN to move flexibly on different grounds.The open electrical
interface and communication interface are configured at the tail of TITAN, which is convenient for
users to carry out secondary development. The design and selection of the electrical interface
adopts aviation waterproof connectors, which is beneficial to the expansion and use of users on
the one hand, and makes the robot platform Can be used in some harsh environments. A standard
aluminum extension bracket is installed on the top of TITAN, which is convenient for users to carry
external equipment for expansion.
2.1 Status of the TITAN
The user can check the status of the TITAN through its CAN message. Please refer to Table 2.1 for
specific status.
Status Description
The current battery voltage can be viewed through BMS (Battery
Voltage
Management System) feedback
9 / 49
Powered Status Lights on indicate power is on.
When the SOC (State of Charge) of the battery is lower than 15% through
BMS feedback, the front and rear lights of the RANGER will flash as a
Low Voltage reminder. When the battery power is detected lower than 10%, the
Warning 4WD chassis will actively cut off the power supply for external
equipment and driver to protect the battery. At this time, the chassis will
not move and accept external command control.
Detailed Status
Check by CAN message
Information
Table 2.1 Status Description Table for the TITAN
2.2 Description of Electrical Interfaces
Figure 2.2 Back View of the TITAN
10 / 49
The TITAN chassis is equipped with an aviation expansion interface at the rear, which includes a
set of power supplies and a set of CAN communication interfaces. This allows users to provide
power (load current not exceeding 15A, voltage range 46-50V) and communication for expansion
devices. The specific pin definitions are shown in the diagram below. It is important to note that
the expansion power supply is internally controlled, and it will automatically cut off power when
the battery voltage is below the safety voltage. Therefore, users need to be aware that the TITAN
chassis platform will issue a low voltage warning notification before reaching the critical voltage,
and users should pay attention to charging during use.
Pin Function and
Pin Type Note
Number Definition
Positive terminal. The voltage range is
1 Power supply VCC 46~50 V
The load current cannot exceed 15 A.
2 Power supply GND Negative terminal
3 CAN CAN_H CAN Hi (High)
4 CAN CAN_L CAN Lo (Low)
Figure 2.3 Pin descriptions of the circular connector
11 / 49
2.3 Remote Control Instructions
Figure 2.4 Introduction of the remote control
As shown in the diagram, the functions of the buttons are defined as follows:
SWB is the control mode selection switch. When it is switched to the top position, it is in
command control mode. When it is switched to the middle position, it is in remote control mode.
SWA is the parking switch. When it is switched to the bottom position, the parking mode is
released. When it is switched to the top position, it is in parking mode (remote control can only be
performed after releasing the parking mode).
SWC is the light control switch. For the front lights: When SWC switch is in the bottom position, it
is in normally closed mode. When it is in the middle position, it is in normally open mode. When it
is in the top position, it is in breathing light mode. For the rear lights: When it is switched to the
bottom position, the lights are turned off (SWB needs to be switched to remote control mode first).
12 / 49
After starting the TITAN mobile robot chassis normally, turn on the remote controller and switch
SWB to remote control mode. This will allow you to control the movement of the TITAN platform
using the remote controller.
SWD is the off-road mode switch stick. When switched to the upper position, it is in normal mode.
When switched to the lower position, it is in off-road mode. In off-road mode, the chassis drive
motors operate in independent front and rear speed closed-loop mode to prevent power loss due
to electronic differential when one or more wheels are suspended. The switch to off-road mode
can only be successful when the chassis is completely stationary. To ensure smooth chassis
motion control, please turn off the off-road mode under normal road conditions.
When SWA is switched up + SWB is switched to the middle + SWC is switched down + SWD is
switched down + the left scroll wheel is slid to the top = Enter the front steering calibration mode.
In this mode, you can adjust the front wheel angle using the right joystick. Pressing KEY1 sets the
current position as the zero point, and a restart is required for it to take effect.
When SWA is switched up + SWB is switched to the middle + SWC is switched down + SWD is
switched down + the left scroll wheel is slid to the bottom = Enter the rear steering calibration
mode. In this mode, you can adjust the rear wheel angle using the right joystick. Pressing KEY1
sets the current position as the zero point, and a restart is required for it to take effect.
Note: Front and rear steering need to be set separately. After setting the front wheels, restart once
before setting the rear wheels.
Pressing KEY1 in any case = forcibly clear all errors of the RANGER. Attention! To be used only in
special cases where safety is guaranteed.
3 Usage and Development
This part mainly introduces the basic operation and usage of the TITAN, and how to carry out
secondary development through the external CAN interface and the CAN bus protocol.
3.1 Operation
Check
Check the TITAN status
Check whether there is any obvious abnormality in the TITAN; if so, please contact after-sales
support;
13 / 49
When using it for the first time, check whether the power switch in the rear electrical panel is
pressed, if pressed, please press it, and then release it. At this time, the power switch is released,
and the TITAN is powered off.
Power on and off
The switch marked with "STOP" at the rear of the TITAN is an emergency stop switch. Pressing it
will stop the TITAN immediately and turning it clockwise will exit the emergency stop mode.
Charge
Check the battery voltage. The normal voltage range is 46~50 V. If there is a continuous buzzer
sound "Beep, beep", it indicates that the battery voltage is too low, please charge it in time.
This product is equipped with a 20A charger by default. To Charge the TITAN, please insert the
plug of the charger into its charging socket, connect the charger to the power supply, and turn on
the switch on the charger.
Connection of the CAN Cable
The 4WD chassis is shipped with an circular connector male head. The definition of its lines can
refer to the figure below:
14 / 49
Figure 3.1 Overview of the circular connector
Implementation of CAN command control
Start the TITAN normally, turn on the remote control, and then switch the SWB to the command
control mode (move SWB to the top). At this time, the TITAN will accept commands from the CAN
bus, and the host can also analyze the status of the TITAN using the feedbacked real-time data
through the CAN bus. Refer to the CAN communication protocol for details. (By default, the
chassis is in standby mode when the chassis is started and the remote control is not started. At
this time, can data can be sent to switch the control mode of the chassis. When the remote
control is turned on, the remote control has the first control right, which mode the remote control
is in, and which mode the chassis is in. )
3.2 CAN Communication Protocol
The CAN communication protocol in this product is CAN2.0B standard, its communication baud
rate is 500 K, and its message format is the MOTOROLA format. Through the external CAN
interface, users can switch the control model and control the linear speed and steering angle of
the TITAN. The TITAN will real-time feedback the current movement status information (including
the integrated movement information of the vehicle and the detailed movement information of
each wheel) and the system status information (including self-diagnostic error codes).
Command System Status Feedback Command
Period Receive
Node for sending Node for receiving ID
(ms) timeout (ms)
Drive-by-wire Decision-making and
0x211 20ms None
chassis control unit
Data length 0x08
Byte Meaning Data type Note
0x00 The system is normal
0x02 The system is abnormal
byte [0] Current unsigned int8
vehicle status
15 / 49
0x00 Standby mode
byte [1] Control mode unsigned int8 0x01 CAN Command control mode
0x03 Remote control mode
High order
byte [2] byte of battery
voltage
unsigned int16 Actual voltage X 10 (the unit is 0.1 V)
Low order
byte [3] byte of battery
voltage
Highest order
byte [4] byte of error
message
High order
byte [5] byte of error
message
Refer to the error message table for
unsigned int32
details
Low order
byte [6] byte of error
message
Lowest order
byte [7] byte of error
message
Error message table
Error message
16 / 49
Byte Bit Meaning
Reserved, the default value is
byte [4]
0
Front steering encoder status
bit [0]
(0: no fault 1: fault)
Rear steering encoder status
bit [1]
(0: no fault 1: fault)
Reserved, the default value is
bit [2]
0
byte [5] Reserved, the default value is
bit [3]
0
Reserved, the default value is
bit [4]
0
Safety edge collision status,
(0: normal; 1: triggered, the
bit [5]
chassis should be stopped
immediately.)
Reserved, the default value is
bit [6]
0
Reserved, the default value is
bit [7]
0
driver status (0: unfaulty; 1:
bit [0]
faulty)
Communication connection
byte [6]
bit [1] status with upper layer (0:
unfaulty; 1: faulty)
Reserved, the default value is
bit [2]
0
17 / 49
Reserved, the default value is
bit [3]
0
Reserved, the default value is
bit [4]
0
Reserved, the default value is
bit [5]
0
Over temperature protection
bit [6]
status (0: normal; 1: triggered)
Over current protection
bit [7]
status (0: normal; 1: triggered)
byte [7] Battery undervoltage status
bit [0]
(0: normal; 1: triggered)
Reserved, the default value is
bit [1]
0
Remote control lost
bit [2] connection protection status
(0: normal; 1: triggered)
No. 1 motor driver
bit [3] communication status (0:
unfaulty; 1: faulty)
No. 2 motor driver
bit [4] communication status (0:
unfaulty; 1: faulty)
No. 3 motor driver
bit [5] communication status (0:
unfaulty; 1: faulty)
No. 4 motor driver
bit [6] communication status (0:
unfaulty; 1: faulty)
18 / 49
Reserved, the default value is
bit [7]
0
The motion control feedback frame includes the current linear speed and steering angle of the
vehicle.
The details of the protocol are as follows
Command Motion Control Feedback Command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire Decision-making
0x221 20ms None
chassis and control unit
Data length 0x08
Byte Meaning Data type Note
High order
byte of speed
byte [0] Actual speed X 1000 (the unit is
signed int16
byte [1] 0.001 m/s)
Low order
byte of speed
byte [2] Reserved - 0X00
byte [3] Reserved - 0X00
byte [4] Reserved - 0X00
byte [5] Reserved - 0X00
19 / 49
High order
byte of steering
angle
byte [6] Actual steering angle X 100 (the unit
signed int16
byte [7] is 0.001 rad)
Low order
byte of steering
angle
The motion control frame includes the linear speed control command and the steering
angle control command. The details of the protocol are as follows:
Command Control Command
Node for Period Receive
sending
Node for receiving ID
(ms) timeout (ms)
Decision-
making and Node for the chassis 0x111 20ms 500ms
control unit
Data length 0x08
Byte Meaning Data type Note
Vehicle body traveling speed,
High order byte of
unit mm/s (effective value +
byte [0] linear speed
signed int16 -3000, effective value +
byte [1] Low order byte of
-1500 when the steering
linear speed
angle is 0.087rad)
byte [2] Reserved - 0X00
byte [3] Reserved - 0X00
byte [4]
Reserved - 0X00
byte [5]
20 / 49
High order byte of Steering inside angle, unit:
byte [6] steering angle 0.001rad (effective value: +
signed int16
byte [7] Low order byte of -367, left turning direction is
steering angle a positive value)
PS: In CAN command mode, it is necessary to ensure that the 0X111 command frame is sent with
a period of less than 500ms (recommended period is 20ms). Otherwise, TITAN will consider it as a
loss of control signal heartbeat and enter an error state (0X211 feedback indicating upper-level
communication loss). After the system reports an error, it will enter standby mode. If the 0X111
control frame resumes normal sending period at this time, the upper-level communication loss
error will be automatically cleared, and the control mode will be restored to CAN control mode.
As shown in Figure 3.2.1, when TITAN is in this state, the feedback rotation angle is (α3+α4)/2, the
negative value is the left turning direction, and the positive value is the right turning direction; the
feedback speed is the average speed of the four wheels (ie Chassis movement line speed), the
negative value is reverse, the positive value is forward. If you need to check the detailed rotation
angle and speed information of each wheel, refer to the 0X271 and 0X281 feedback frames.
21 / 49
图3.2.1 TITAN structure
The mode setting frame is used to set the terminal control interface, and the details of the protocol
are as follows.
Command Control Command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
22 / 49
Decision-making Node for the
0x421 None None
and control unit chassis
Data length 0x01
Byte Meaning Data type Note
0x00 Standby mode
byte [0] Control mode unsigned int8 0x01 CAN command control mode
Boot into standby mode by default
Control mode description: when the chassis is powered on and the remote control is not
connected, the control mode is standby mode. At this time, the chassis only receives control
mode commands and does not respond to other commands. To control the chassis using CAN,
you need to switch control mode to CAN command control mode first. If the remote control is
turned on, the remote control has the highest priority, which can block the control command and
switch the control mode. The status setting frame is used to clear system errors, and the details of
the protocol are as follows.
Command Control Command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Decision-making Node for the
0x441 None None
and control unit chassis
Data length 0x01
Byte Meaning Data type Note
23 / 49
0x00 Clear all non-critical faults
0x01~0x04 respectively correspond
to clearing the communication
failure of No. 1~4 motor drivers
0x09 Clear the battery undervoltage
fault and try to restore the power
Error clearing supply
byte [0] unsigned int8
command 0x0a Clear remote control signal
loss fault
0x0b~0x0c respectively correspond
to clearing the faults of the front and
rear steering encoders
0x0f Clear overcurrent fault
0x10 Clear over temperature fault
The parking control command is used to control the motor brake of the drive wheel, and the
details of the protocol are as follows.
Command Parking control command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Decision-making Node for the
0x131 None None
and control unit chassis
Data length 0x01
Byte Meaning Data type Note
0x00 Open parking (lock brake)
0x01 Close the parking (unlock the
Parking
byte [0] unsigned int8 brake)
command
The brake needs to be unlocked to
control the speed of the chassis
24 / 49
Command CAN upgrade bus silent mode setting command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Decision-making Node for the
0x422 None None
and control unit chassis
Data length 0x01
Byte Meaning Data type Note
0x00 Exit CAN upgrade bus silent
mode
0x01 Enter CAN upgrade bus silent
mode
byte [0] Control mode unsigned int8 In CAN upgrade bus silent mode,
the chassis VCU pauses sending
CAN data to the bus for firmware
upgrade, and resumes data
feedback after exiting.
If obstacle crossing is required, you can enter the off-road mode. In off-road mode, the chassis
drive motors adopt independent front and rear speed closed-loop mode to prevent power loss
due to electronic differential when wheels are slipping in the air. Switching to off-road mode can
only be done after the chassis is completely stationary.
Command Off-road mode setting command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Decision-making Node for the
0x423 None None
and control unit chassis
25 / 49
Data length 0x01
Byte Meaning Data type Note
0x00 Chassis exits off-road mode
byte [0] Control mode unsigned int8
0x01 Chassis enters off-road mode
Sample data, the following data is only for testing.
byte [0] byte [1] byte [2] byte [3] byte [4] byte [5] byte [6] byte [7]
0x00 0x96 0x00 0x00 0x00 0x00 0x00 0x00
In addition to the status of the chassis itself, its feedback information also includes the steering
angle and speed of the four wheels, the current of the motor, the encoder information, and the
temperature information.
The details of the protocol are as follows:
Feedback information of speed, current, and position of motor
Command High-speed feedback information frame for motor driver
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire Decision-making
0x251~0x254 20ms None
chassis and control unit
Data length 0x08
Byte Meaning Data type Note
26 / 49
High order
byte of motor
The current speed of the motor,
byte [0] speed
signed int16 whose unit is RPM (Revolutions Per
byte [1] Low order
Minute)
byte of motor
speed
High order
byte of motor
byte [2] current The present current of the motor,
signed int16
byte [3] Low order whose unit is 0.1 A
byte of motor
current
Highest order
byte of position
byte [4] High order
byte [5] byte of position
signed int32 The current position of the motor,
byte [6] Low order
whose unit is the number of pulses
byte [7] byte of position
Lowest order
byte of position
Feedback of temperature voltage and status of motor
Command Low-speed information feedback frame for motor
driver
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire Decision-making
0x261~0x264 100ms None
chassis and control unit
Data length 0x08
Byte Meaning Data type Note
27 / 49
High order
byte [0] byte of driver
voltage
The current driver voltage, whose
unsigned int16
unit is 0.1 V
Low order
byte [1] byte of driver
voltage
High order
byte [2] byte of drive
temperature
signed int16 The unit is 1 ℃.
Low order
byte of
byte [3]
driver temperatur
e
Motor
byte [4] signed int8 The unit is 1 ℃.
temperature
byte [5] Driver status unsigned int8 See Table 2 for details
byte [6] Reserved - 0X00
byte [7] Reserved - 0X00
Table 2 Driver status
Byte Bit Meaning
byte[5] bit[0] Power supply voltage status (0: normal; 1: too low)
bit[1] Motor temperature status (0: normal; 1: over temperature)
bit[2] The current status of the driver(0: normal; 1: over-current)
bit[3] Driver temperature status (0: normal; 1: over temperature)
28 / 49
bit[4] Sensor status (0: Normal; 1: Abnormal)
bit[5] Driver status (0: Normal; 1: Abnormal)
bit[6] Drive enable status (0: disable; 1: enable)
bit[7] Reserved
Steering zero point setting and feedback commands are used to calibrate the zero point. The
details of the protocol are as follows:
Steering zero point setting command
Command Steering zero point setting command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Decision-making Node for the
0×431 None None
and control unit chassis
Data length 0×01
Byte Meaning Data type Note
Set the current
Set the current position as zero
Byte [0] position as the unsigned int8
point, the fixed value: 0xAA
zero point
Steering zero point setting feedback command
Command Steering zero point setting feedback command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Node for the Decision-making
0×43A None None
chassis and control unit
Data length 0×01
29 / 49
Byte Meaning Data type Note
Set the current
0xEE set the current position to
Byte [0] position as the unsigned int8
zero point successfully
zero point
Steering angle feedback
Command Information feedback frame of steering angle
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire Decision-making
0x271 20ms None
chassis and control unit
Data length 0x08
Byte Meaning Data type Note
High order byte
of front steering
byte [0] inner turn angle
signed int16 Current steering angle, unit 0.001rad
byte [1] Low order byte
of front steering
inner turn angle
High order byte
of rear steering
byte [2] inner turn angle
signed int16 Current steering angle, unit 0.001rad
byte [3] Low order byte
of rear steering
inner turn angle
byte [4]
Reserved - 0X00
byte [5]
30 / 49
byte [6]
Reserved - 0X00
byte [7]
Rotational speed feedback
Due to the adoption of a drive axle in the chassis, the front wheel speed is actually the drive shaft
speed, which can be understood as the average of the front left and front right wheel speeds. The
same applies to the rear wheels.
Command Information feedback frame of rotational speed
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire Decision-making
0x281 20ms None
chassis and control unit
Data length 0x08
Byte Meaning Data type Note
High order byte
of front wheel
byte [0] rotational speed The current rotational speed,
signed int16
byte [1] Low order byte whose unit is mm/s
of front wheel
rotational speed
High order byte
of rear wheel
byte [2] rotational speed The current rotational speed,
signed int16
byte [3] Low order byte whose unit is mm/s
of rear wheel
rotational speed
byte [4]
Reserved - 0X00
byte [5]
31 / 49
byte [6]
Reserved - 0X00
byte [7]
Odometer information feedback frame is as follows
Command Odometer information feedback
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire Decision-making
0×311 20ms None
chassis and control unit
Data length 0x08
Byte Meaning Data type Note
Front wheel
odometer
highest byte
Front wheel
odometer
byte [0] second highest
Chassis front wheel odometer
byte [1] byte
signed int32 feedback,
byte [2] Front wheel
Unit: mm
byte [3] odometer
second lowest
byte
Front wheel
odometer lowest
byte
32 / 49
Rear wheel
odometer
highest byte
Rear wheel
odometer
byte [4] second highest
Chassis rear wheel odometer
byte [5] byte
signed int32 feedback,
byte [6] Rear wheel
Unit: mm
byte [7] odometer
second lowest
byte
Rear wheel
odometer lowest
byte
The remote control information feedback frame is as follows
Command Remote control information feedback
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire Decision-making
0x241 20ms None
chassis and control unit
Data length 0x08
Byte Meaning Data type Note
33 / 49
bit[0-1]: SWA: 2-Upper gear, 3-
Lower gear
bit[2-3]: SWB: 2-Upper gear, 1-
Remote control Middle gear, 3-Lower gear
byte [0] unsigned int8
SW feedback bit[4-5]: SWC: 2-Upper gear, 1-
Middle gear, 3-Lower gear
bit[6-7]: SWD: 2-Upper gear, 3-
Lower gear
Right joystick
byte [1] unsigned int8 Value range: [-100,100]
left/right
Right joystick
byte [2] unsigned int8 Value range: [-100,100]
up/down
Left joystick
byte [3] unsigned int8 Value range: [-100,100]
up/down
Left
byte [4] unsigned int8 Value range: [-100,100]
joystick left/right
byte [5] left knob VRA unsigned int8 Value range: [-100,100]
byte [6] Reserved -- 0x00
Counting
byte [7] unsigned int8 0-255 cycle count
verification
Battery BMS data feedback, and the details of the protocol are as follows
Command The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
34 / 49
Drive-by-wire Decision-making
0x361 500ms None
chassis and control unit
Data length 0x08
Byte Meaning Data type Note
Battery SOC
byte [0] (State of unsigned int8 Range 0~100
Charge)
Battery
byte [1] SOH (State of unsigned int8 Range 0~100
Health)
High order byte
byte [2] of battery voltage
unsigned int16 Unit: 0.01 V
byte [3] Low order byte
of battery voltage
High order byte
byte [4] of battery current
signed int16 Unit: 0.1 A
byte [5] Low order byte
of battery current
High order byte
of battery
byte [6] temperature
signed int16 Unit: 0.1 ℃
byte [7] Low order byte
of battery
temperature
35 / 49
Command
The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire Decision-making
0x362 500ms None
chassis and control unit
Data length 0x04
Byte Meaning Data type Note
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
byte [0] Alarm Status 1 unsigned int8 temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [1] Alarm Status 2 unsigned int8 BIT0: Charging overcurrent
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
byte [2] Warning Status 1 unsigned int8 temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [3] Warning Status 2 unsigned int8 BIT0: Charging overcurrent
The feedback data of BMS for No. 1 battery
Command The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
36 / 49
Decision-
Drive-by-wire
making and 0x363 500ms None
chassis
control unit
Data length 0x08
Byte Meaning Data type Note
byte [0] Battery SOC unsigned int8 Range 0~100
byte [1] Battery SOH unsigned int8 Range 0~100
High order byte
byte [2] of battery voltage
unsigned int16 Unit: 0.01 V
byte [3] Low order byte
of battery voltage
High order byte
byte [4] of battery current
signed int16 Unit: 0.1 A
byte [5] Low order byte
of battery current
High order byte
of battery
byte [6] temperature
signed int16 Unit: 0.1 ℃
byte [7] Low order byte
of battery
temperature
Command
The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
37 / 49
Decision-
Drive-by-wire
making and 0x364 500ms None
chassis
control unit
Data length 0x04
Byte Meaning Data type Note
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
byte [0] Alarm Status 1 unsigned int8 temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [1] Alarm Status 2 unsigned int8 BIT0: Charging overcurrent
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
byte [2] Warning Status 1 unsigned int8 temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [3] Warning Status 2 unsigned int8 BIT0: Charging overcurrent
The feedback data of BMS for No. 2 battery
Command The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
38 / 49
Decision-
Drive-by-wire
making and 0x365 500ms None
chassis
control unit
Data length 0x08
Byte Meaning Data type Note
byte [0] Battery SOC unsigned int8 Range 0~100
byte [1] Battery SOH unsigned int8 Range 0~100
High order byte
byte [2] of battery voltage
unsigned int16 Unit: 0.01 V
byte [3] Low order byte
of battery voltage
High order byte
byte [4] of battery current
signed int16 Unit: 0.1 A
byte [5] Low order byte
of battery current
High order byte
of battery
byte [6] temperature
signed int16 Unit: 0.1 ℃
byte [7] Low order byte
of battery
temperature
Command
The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
39 / 49
Decision-
Drive-by-wire
making and 0x366 500ms None
chassis
control unit
Data length 0x04
Byte Meaning Data type Note
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
byte [0] Alarm Status 1 unsigned int8 temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [1] Alarm Status 2 unsigned int8 BIT0: Charging overcurrent
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
byte [2] Warning Status 1 unsigned int8 temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [3] Warning Status 2 unsigned int8 BIT0: Charging overcurrent
3.3 TITAN use manual for ROS
40 / 49
ROS (Robot Operating System) provides some standard operating system services, such as
hardware abstraction, low-level device control, implementation of commonly used functionality,
message-passing between processes, and package management. ROS is based on a graph
architecture, where processing takes place in nodes that may receive, post, and multiplex various
information (such as sensor data, control, state, planning, and other messages). Currently ROS
mainly supports UBUNTU OS.
Development Preparation
Hardware Preparation
● CANlight CAN communication module X1
● Laptop X1
● AGILEX TITAN mobile robot chassis X1
● AGILEX supporting remote controller FS-i6s X1
● Aviation connector on the rear of the AGILEX TITAN X1
使用示例环境说明
● Ubuntu 18.04 LTS
● ROS
● Git
Hardware Connection and Preparation
Pull out the CAN wires of the circular connector on the rear of TITAN, and connect can_H and
can_L wires of the CAN to the CAN_TO_USB adapter; power on the TITAN; connect the
CAN_TO_USB adapter to the USB port of the laptop. The wiring diagram is shown in the figure
below.
The CAN wiring diagram
41 / 49
ROS Installation and Environment Setup
Please refer to http://wiki.ros.org/kinetic/Installation/Ubuntu for details.
Test the Communication between CANABLE hardware and CAN
Set the CAN-TO-USB adapter
● Enable the gs_usb kernel module
sudo modprobe gs_usb
● Set baud rate to 500k and enable the CAN-TO-USB adapter
sudo ip link set can0 up type can bitrate 500000
● If there is no error in the previous steps, you can check the CAN devices with the command
below
ifconfifig -a
● Install and use can-utils to test hardware
sudo apt install can-utils
● If the CAN-TO-USB adapter has been connected to the TITAN and the TITAN has been
powered on, the command below can be used to monitor the data from the TITAN.
candump can0
42 / 49
● Please refer to:
[1] https://github.com/agilexrobotics/agx_sdk
[2] https://wiki.rdu.im/_pages/Notes/Embedded-System/-Linux/can-bus-in-linux.html
3.4 The Github ROS development kit and user manual
:
TITAN_base: An important ROS node for sending and receiving CAN messages, using topics
to control the movement of the TITAN, and read its status, which is based on the
ROS communication architecture.
:
TITAN_msgs Define the message format of the topic for TITAN status feedback
TITAN_bringup:The startup file of the TITAN node and the keyboard_control node, and the script
to enable the USB_TO_CAN module
Send commands to control the TITAN through the keyboard:
1. Run the TITAN node
roslaunch titan_bringup titan_minimal.launch
Note that the Agilex USB_TO_CAN module needs to be enabled before running the RANGER
node. The command is as follows: rosrun TITAN_bringup bringup_can2usb.bash. This command
only needs to be executed once after the USB_TO_CAN module is powered on.
2. Run the keyboard_control node
roslaunch titan_bringup titan_teleop_keyboard.launch
Please pay attention to check the output of the terminal, and use the specific keys to control the
movement of TITAN
3.5 Firmware Upgrade
43 / 49
To facilitate users to upgrade the firmware of the 4WD chassis and bring customers a better
experience, the TITAN chassis provides a hardware interface and a software for upgrading
firmware. The GUI (Graphical User Interface) of the software is shown in the figure below.
Upgrade Preparation
● Agilex CAN debugging module X 1
● Micro USB cable X 1
● TITAN chassis X 1
● A computer (WINDOWS OS (Operating System)) X 1
Upgrade Process
1.Plug in the USBTOCAN module on the computer, and then open the
AgxCandoUpgradeToolV1.3_boxed.exe software (the sequence cannot be wrong, first open the
software and then plug in the module, the device will not be recognized).
2.Click the Open Serial button, and then press the power button on the car body. If the connection
is successful, the version information of the main control will be recognized, as shown in the figure.
44 / 49
3.Click the Load Firmware File button to load the firmware to be upgraded. If the loading is
successful, the firmware information will be obtained, as shown in the figure
4.Click the node to be upgraded in the node list box, and then click Start Upgrade Firmware to
start upgrading the firmware. After the upgrade is successful, a pop-up box will prompt.
45 / 49
3.6 The vehicle body coordinate system
46 / 49
The vehicle body coordinate system is defined as follows: the center of the vehicle is the origin,
the positive direction of the X-axis points to the front of the vehicle, the positive direction of the Y-
axis points to the left side of the vehicle, and the positive direction of the Z-axis points upwards.
4 Maintenance Instructions
4.1 Maintenance method
The vehicle maintenance
When the tires are severely worn, please replace them in time.
Battery maintenance
If the battery is not used for a long time, please don't forget to charge it every 2 to 3 months.
5 Product Size
47 / 49
48 / 49
49 / 49
[READING ORDER TEXT]
1/49
TITAN
AgileX Robotics Team
用户手册 V.2.0.1 2023.08
Document version
TITAN User Manual
No. Version Date Edited by Reviewer Notes
1 V1.0.0 2022/10/15 何士玉 first draft
2 V2.0.0 2023/3/23 李圣望、何士玉
Update
agreement
content2/49
Before using the robot, any individual or organization must read and understand the manual. If
you have any questions about it, please do not hesitate to contact us at support@agilex.ai. It is
very important that you should follow and implement all instructions and guidelines in this
manual. Please pay extra attention to the warnings.
Important Safety Information
This manual does not cover the design, installation, and operation of a robotic application, nor
does it include any equipment that may affect the safety of a robotic system. A robot system
that uses the TITAN should be designed and used in compliance with the safety requirements
and other standards of the corresponding countries.
Any users of the TITAN should comply with laws and regulations of relevant countries and
ensure that there are no obvious hazards in the application of the TITAN. This includes but is
not limited to the following:
Responsibility
Do a risk assessment of the robotic system that uses the TITAN.
The risk assessment should include additional safety equipment to other machinery.
Please ensure that the equipment of the whole robotic system, including software and hardware,
are designed, and installed correctly.
The TITAN is not an autonomous mobile robot with anti-collision, anti-fall, biological
approach warning, and other safety functions. These safety functions are expected to be
developed and assessed by system integrators and end customers under relevant safety
regulations and laws to ensure there are not any major dangers and potential safety hazards in
their practical applications.
3 V2.0.1 2023/09/02 谢瑞亲 3/49
Read all technical documents: including the risk assessment and this manual.
Know the possible safety risks before using the TITAN.
Use Environment
For the first use, please read this manual carefully to understand the basic operation and
operating specifications.
Remote control operation should be in a relatively open area. The TITAN does not have any
automatic obstacle avoidance sensors.
Please use the TITAN under the ambient temperature of 0 ℃~ 40 ℃.
The TITAN’s waterproof and dustproof level is IP22 if it is not customized
Check
Make sure each device is fully charged.
Make sure the TITAN has no obvious abnormalities.
Make sure the remote control has sufficient battery power
Operation Precautions
Ensure that the surrounding area is relatively open when operating the TITAN.
Please do remote control within sight.
The maximum load of the TITAN is 150 KG. Please ensure that the payload does not exceed
150 KG when using.
When installing external equipment on the TITAN, Please ensure their centroid location is at
the TITAN’s center of rotation.
Please charge the TITAN in time after low-battery alarm.
When the TITAN is abnormal, please stop using it immediately to avoid secondary injury.
When the TITAN is abnormal, please contact the technical support immediately, and do not
handle it without professional suggestion.4/49
Please use the TITAN in an environment that does not exceed its IP protection level.
Do not push the TITAN directly.
Tail extension power supply current does not exceed 15A, total power does not exceed 720W
Battery Precautions
The batteries of TITAN products are not fully charged when they leave the factory. The specific
battery voltage and power can be displayed through the voltage indicator at the rear of the TITAN
chassis or through the vol and batt on the remote control.
Please do not charge the battery after it is exhausted. Please charge it in time when the low
battery of the TITAN remote control is lower than 15% or the tail voltage display is lower
than 25V.
Static storage conditions: The best temperature for storage is -10°C~40°C. When the battery is
not in use, it must be charged and discharged once a month, and then stored at full voltage. Do
not leave the battery Put it in fire, or heat the battery, do not store the battery at high temperature.
Charging: You must use the matching lithium battery charger for charging. Do not charge the
battery below 0°C. Do not use non-original standard batteries, power supplies, and chargers.
Precautions for use environment
The operating temperature of TITAN is -10°C~40°C, please do not use it in an environment where
the temperature is lower than -10°C and higher than 40°C
Do not use in environments with corrosive or flammable gases or near flammable substances
Please do not use it around heating elements such as heaters or large winding resistors
The waterproof and dustproof grade of TITAN is IP22, please pay attention to the use environment,
check and remove rust regularly
It is recommended that the altitude of the use environment should not exceed 1000M
It is recommended that the ambient temperature difference between day and night does not
exceed 25°C
Regular inspection and maintenance of track tensioning wheels
Safety Precautions5/49
If you have any questions about the use process, please follow the relevant instruction manual or
consult relevant technical personnel
Before using the equipment to operate, pay attention to the situation on site to avoid personnel
safety problems caused by misoperation
In case of emergency, power off the device by tapping the emergency stop button
Do not modify the internal equipment structure without technical support and permission
When the equipment is abnormal, please stop using it immediately to avoid secondary injury
When the device is abnormal, please contact the relevant technical personnel, and do not handle
it without authorization.
CONTENTS6/49
1 Introduction to TITAN
CONTENTS
Document version
Important Safety Information
CONTENTS
1 Introduction to TITAN
1.1 Specifications
1.2 Required for Development
2 Basic Introduction
2.1 Status of the TITAN
2.2 Description of Electrical Interfaces
2.3 Remote Control Instructions
3 Usage and Development
3.1 Operation
3.2 CAN Communication Protocol
3.3 TITAN use manual for ROS
3.4 The Github ROS development kit and user manual
3.5 Firmware Upgrade
3.6 The vehicle body coordinate system
4 Maintenance Instructions
4.1 Maintenance method
5 Product Size 7/49
TITAN is a programmable front and rear dual-steering UGV (UNMANNED GROUND VEHICLE),
which is a chassis with a modular design. Compared with the former AKM chassis, TITAN not only
greatly reduces the turning radius, but also is more stable and safer. have wider applications.
TITAN chassis, suitable for a variety of complex terrain. At the same time, it can be equipped with
stereo cameras, lidar, GPS, IMU, manipulators and other equipment, and is applied to unmanned
inspection, security, scientific research, exploration and logistics and other fields.
1.1 Specifications
Type Description Parameters
Mechanical
Dimensions (mm) 1640×980×1440
Axle Track(mm) 860
Wheel Base(mm) 845
Rated power (w) 1000
Rated torque (N.M) 556
Performance
Maximum Speed(m/s) 10.8
Motion Mode Front and rear Ackermann
Maximum Obstacle Height
(mm)
100(vertical obstacles
and fully loaded)
Maximum Climbing Angle
(°) 10
Weight(kg) 280(two batteries)
Maximum Load (kg) 300
Battery Life (h) >5h(1.4km/h test)
Charging efficiency 1C8/49
1.2 Required for Development
TITAN can be equipped with FS remote control when it leaves the factory. Users can control the
chassis through the remote control to complete mode switching, movement and steering control.
TITAN is equipped with a standard CAN communication interface, and users can carry out
secondary development through the CAN interface.
2 Basic Introduction
This part is a basic introduction to the TITAN, mobile robot chassis. After reading this part, users
and developers can have an overall understanding about it. As shown in Figure 2.1 below, it is an
overview of the TITAN.
Battery Type
Lithium iron phosphate
battery
Single Battery Capacity(ah) 24(Can support up to 2
batteries)
Rated Voltage(v) 48
Functional Application
Engineering Investigation
Energy Inspection
Mine Transportation
Intelligent Security
Logistics
Agricultural Product
Collection and Transportation9/49
Figure 2.1 Overview of the TITAN
TITAN adopts a modular and intelligent design concept as a whole. It adopts a pneumatic tire
design on the power module, coupled with a powerful permanent magnet synchronous motor,
which makes the TITAN robot chassis have a strong battery life and load capacity. The motor with
a power of 1000W enables TITAN to move flexibly on different grounds.The open electrical
interface and communication interface are configured at the tail of TITAN, which is convenient for
users to carry out secondary development. The design and selection of the electrical interface
adopts aviation waterproof connectors, which is beneficial to the expansion and use of users on
the one hand, and makes the robot platform Can be used in some harsh environments. A standard
aluminum extension bracket is installed on the top of TITAN, which is convenient for users to carry
external equipment for expansion.
2.1 Status of the TITAN
The user can check the status of the TITAN through its CAN message. Please refer to Table 2.1 for
specific status.
Status Description
Voltage
The current battery voltage can be viewed through BMS (Battery
Management System) feedback10/49
Table 2.1 Status Description Table for the TITAN
2.2 Description of Electrical Interfaces
Figure 2.2 Back View of the TITAN
Powered Status Lights on indicate power is on.
Low Voltage
Warning
When the SOC (State of Charge) of the battery is lower than 15% through
BMS feedback, the front and rear lights of the RANGER will flash as a
reminder. When the battery power is detected lower than 10%, the
4WD chassis will actively cut off the power supply for external
equipment and driver to protect the battery. At this time, the chassis will
not move and accept external command control.
Detailed Status
Information
Check by CAN message11/49
The TITAN chassis is equipped with an aviation expansion interface at the rear, which includes a
set of power supplies and a set of CAN communication interfaces. This allows users to provide
power (load current not exceeding 15A, voltage range 46-50V) and communication for expansion
devices. The specific pin definitions are shown in the diagram below. It is important to note that
the expansion power supply is internally controlled, and it will automatically cut off power when
the battery voltage is below the safety voltage. Therefore, users need to be aware that the TITAN
chassis platform will issue a low voltage warning notification before reaching the critical voltage,
and users should pay attention to charging during use.
Figure 2.3 Pin descriptions of the circular connector
Pin
Number
Pin Type
Function and
Definition
Note
1 Power supply VCC
Positive terminal. The voltage range is
46~50 V
The load current cannot exceed 15 A.
2 Power supply GND Negative terminal
3 CAN CAN_H CAN Hi (High)
4 CAN CAN_L CAN Lo (Low)12/49
2.3 Remote Control Instructions
Figure 2.4 Introduction of the remote control
As shown in the diagram, the functions of the buttons are defined as follows:
SWB is the control mode selection switch. When it is switched to the top position, it is in
command control mode. When it is switched to the middle position, it is in remote control mode.
SWA is the parking switch. When it is switched to the bottom position, the parking mode is
released. When it is switched to the top position, it is in parking mode (remote control can only be
performed after releasing the parking mode).
SWC is the light control switch. For the front lights: When SWC switch is in the bottom position, it
is in normally closed mode. When it is in the middle position, it is in normally open mode. When it
is in the top position, it is in breathing light mode. For the rear lights: When it is switched to the
bottom position, the lights are turned off (SWB needs to be switched to remote control mode first).13/49
After starting the TITAN mobile robot chassis normally, turn on the remote controller and switch
SWB to remote control mode. This will allow you to control the movement of the TITAN platform
using the remote controller.
SWD is the off-road mode switch stick. When switched to the upper position, it is in normal mode.
When switched to the lower position, it is in off-road mode. In off-road mode, the chassis drive
motors operate in independent front and rear speed closed-loop mode to prevent power loss due
to electronic differential when one or more wheels are suspended. The switch to off-road mode
can only be successful when the chassis is completely stationary. To ensure smooth chassis
motion control, please turn off the off-road mode under normal road conditions.
When SWA is switched up + SWB is switched to the middle + SWC is switched down + SWD is
switched down + the left scroll wheel is slid to the top = Enter the front steering calibration mode.
In this mode, you can adjust the front wheel angle using the right joystick. Pressing KEY1 sets the
current position as the zero point, and a restart is required for it to take effect.
When SWA is switched up + SWB is switched to the middle + SWC is switched down + SWD is
switched down + the left scroll wheel is slid to the bottom = Enter the rear steering calibration
mode. In this mode, you can adjust the rear wheel angle using the right joystick. Pressing KEY1
sets the current position as the zero point, and a restart is required for it to take effect.
Note: Front and rear steering need to be set separately. After setting the front wheels, restart once
before setting the rear wheels.
Pressing KEY1 in any case = forcibly clear all errors of the RANGER. Attention! To be used only in
special cases where safety is guaranteed.
3 Usage and Development
This part mainly introduces the basic operation and usage of the TITAN, and how to carry out
secondary development through the external CAN interface and the CAN bus protocol.
3.1 Operation
Check
Check the TITAN status
Check whether there is any obvious abnormality in the TITAN; if so, please contact after-sales
support;14/49
When using it for the first time, check whether the power switch in the rear electrical panel is
pressed, if pressed, please press it, and then release it. At this time, the power switch is released,
and the TITAN is powered off.
Power on and off
The switch marked with "STOP" at the rear of the TITAN is an emergency stop switch. Pressing it
will stop the TITAN immediately and turning it clockwise will exit the emergency stop mode.
Charge
Check the battery voltage. The normal voltage range is 46~50 V. If there is a continuous buzzer
sound "Beep, beep", it indicates that the battery voltage is too low, please charge it in time.
This product is equipped with a 20A charger by default. To Charge the TITAN, please insert the
plug of the charger into its charging socket, connect the charger to the power supply, and turn on
the switch on the charger.
Connection of the CAN Cable
The 4WD chassis is shipped with an circular connector male head. The definition of its lines can
refer to the figure below:
15/49
Figure 3.1 Overview of the circular connector
Implementation of CAN command control
Start the TITAN normally, turn on the remote control, and then switch the SWB to the command
control mode (move SWB to the top). At this time, the TITAN will accept commands from the CAN
bus, and the host can also analyze the status of the TITAN using the feedbacked real-time data
through the CAN bus. Refer to the CAN communication protocol for details. (By default, the
chassis is in standby mode when the chassis is started and the remote control is not started. At
this time, can data can be sent to switch the control mode of the chassis. When the remote
control is turned on, the remote control has the first control right, which mode the remote control
is in, and which mode the chassis is in.)
3.2 CAN Communication Protocol
The CAN communication protocol in this product is CAN2.0B standard, its communication baud
rate is 500 K, and its message format is the MOTOROLA format. Through the external CAN
interface, users can switch the control model and control the linear speed and steering angle of
the TITAN. The TITAN will real-time feedback the current movement status information (including
the integrated movement information of the vehicle and the detailed movement information of
each wheel) and the system status information (including self-diagnostic error codes).
Command System Status Feedback Command
Node for sending Node for receiving ID
Period
(ms)
Receive
timeout (ms)
Drive-by-wire
chassis
Decision-making and
control unit
0x211 20ms None
Data length 0x08
Byte Meaning Data type Note
byte [0] Current
vehicle status
unsigned int8
0x00 The system is normal
0x02 The system is abnormal16/49
Error message table
byte [1] Control mode unsigned int8
0x00 Standby mode
0x01 CAN Command control mode
0x03 Remote control mode
byte [2]
High order
byte of battery
voltage
unsigned int16 Actual voltage X 10 (the unit is 0.1 V)
byte [3]
Low order
byte of battery
voltage
byte [4]
Highest order
byte of error
message
unsigned int32
Refer to the error message table for
details
byte [5]
High order
byte of error
message
byte [6]
Low order
byte of error
message
byte [7]
Lowest order
byte of error
message
Error message17/49
Byte Bit Meaning
byte [4]
Reserved, the default value is
0
byte [5]
bit [0]
Front steering encoder status
(0: no fault 1: fault)
bit [1]
Rear steering encoder status
(0: no fault 1: fault)
bit [2]
Reserved, the default value is
0
bit [3]
Reserved, the default value is
0
bit [4]
Reserved, the default value is
0
bit [5]
Safety edge collision status,
(0: normal; 1: triggered, the
chassis should be stopped
immediately.)
bit [6]
Reserved, the default value is
0
bit [7]
Reserved, the default value is
0
byte [6]
bit [0]
driver status (0: unfaulty; 1:
faulty)
bit [1]
Communication connection
status with upper layer (0:
unfaulty; 1: faulty)
bit [2]
Reserved, the default value is
018/49
bit [3]
Reserved, the default value is
0
bit [4]
Reserved, the default value is
0
bit [5]
Reserved, the default value is
0
bit [6]
Over temperature protection
status (0: normal; 1: triggered)
bit [7]
Over current protection
status (0: normal; 1: triggered)
byte [7]
bit [0]
Battery undervoltage status
(0: normal; 1: triggered)
bit [1]
Reserved, the default value is
0
bit [2]
Remote control lost
connection protection status
(0: normal; 1: triggered)
bit [3]
No. 1 motor driver
communication status (0:
unfaulty; 1: faulty)
bit [4]
No. 2 motor driver
communication status (0:
unfaulty; 1: faulty)
bit [5]
No. 3 motor driver
communication status (0:
unfaulty; 1: faulty)
bit [6]
No. 4 motor driver
communication status (0:
unfaulty; 1: faulty)19/49
The motion control feedback frame includes the current linear speed and steering angle of the
vehicle.
The details of the protocol are as follows
bit [7]
Reserved, the default value is
0
Command Motion Control Feedback Command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire
chassis
Decision-making
and control unit
0x221 20ms None
Data length 0x08
Byte Meaning Data type Note
byte [0]
byte [1]
High order
byte of speed
Low order
byte of speed
signed int16
Actual speed X 1000 (the unit is
0.001 m/s)
byte [2] Reserved - 0X00
byte [3] Reserved - 0X00
byte [4] Reserved - 0X00
byte [5] Reserved - 0X0020/49
The motion control frame includes the linear speed control command and the steering
angle control command. The details of the protocol are as follows:
byte [6]
byte [7]
High order
byte of steering
angle
Low order
byte of steering
angle
signed int16
Actual steering angle X 100 (the unit
is 0.001 rad)
Command Control Command
Node for
sending
Node for receiving ID
Period
(ms)
Receive
timeout (ms)
Decision-
making and
control unit
Node for the chassis 0x111 20ms 500ms
Data length 0x08
Byte Meaning Data type Note
byte [0]
byte [1]
High order byte of
linear speed
Low order byte of
linear speed
signed int16
Vehicle body traveling speed,
unit mm/s (effective value +
-3000, effective value +
-1500 when the steering
angle is 0.087rad)
byte [2] Reserved - 0X00
byte [3] Reserved - 0X00
byte [4]
byte [5]
Reserved - 0X0021/49
PS: In CAN command mode, it is necessary to ensure that the 0X111 command frame is sent with
a period of less than 500ms (recommended period is 20ms). Otherwise, TITAN will consider it as a
loss of control signal heartbeat and enter an error state (0X211 feedback indicating upper-level
communication loss). After the system reports an error, it will enter standby mode. If the 0X111
control frame resumes normal sending period at this time, the upper-level communication loss
error will be automatically cleared, and the control mode will be restored to CAN control mode.
As shown in Figure 3.2.1, when TITAN is in this state, the feedback rotation angle is (α3+α4)/2, the
negative value is the left turning direction, and the positive value is the right turning direction; the
feedback speed is the average speed of the four wheels (ie Chassis movement line speed), the
negative value is reverse, the positive value is forward. If you need to check the detailed rotation
angle and speed information of each wheel, refer to the 0X271 and 0X281 feedback frames.
byte [6]
byte [7]
High order byte of
steering angle
Low order byte of
steering angle
signed int16
Steering inside angle, unit:
0.001rad (effective value: +
-367, left turning direction is
a positive value)22/49
图3.2.1 TITAN structure
The mode setting frame is used to set the terminal control interface, and the details of the protocol
are as follows.
Command Control Command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)23/49
Control mode description: when the chassis is powered on and the remote control is not
connected, the control mode is standby mode. At this time, the chassis only receives control
mode commands and does not respond to other commands. To control the chassis using CAN,
you need to switch control mode to CAN command control mode first. If the remote control is
turned on, the remote control has the highest priority, which can block the control command and
switch the control mode. The status setting frame is used to clear system errors, and the details of
the protocol are as follows.
Decision-making
and control unit
Node for the
chassis
0x421 None None
Data length 0x01
Byte Meaning Data type Note
byte [0] Control mode unsigned int8
0x00 Standby mode
0x01 CAN command control mode
Boot into standby mode by default
Command Control Command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Decision-making
and control unit
Node for the
chassis
0x441 None None
Data length 0x01
Byte Meaning Data type Note24/49
The parking control command is used to control the motor brake of the drive wheel, and the
details of the protocol are as follows.
byte [0]
Error clearing
command
unsigned int8
0x00 Clear all non-critical faults
0x01~0x04 respectively correspond
to clearing the communication
failure of No. 1~4 motor drivers
0x09 Clear the battery undervoltage
fault and try to restore the power
supply
0x0a Clear remote control signal
loss fault
0x0b~0x0c respectively correspond
to clearing the faults of the front and
rear steering encoders
0x0f Clear overcurrent fault
0x10 Clear over temperature fault
Command Parking control command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Decision-making
and control unit
Node for the
chassis
0x131 None None
Data length 0x01
Byte Meaning Data type Note
byte [0]
Parking
command
unsigned int8
0x00 Open parking (lock brake)
0x01 Close the parking (unlock the
brake)
The brake needs to be unlocked to
control the speed of the chassis25/49
If obstacle crossing is required, you can enter the off-road mode. In off-road mode, the chassis
drive motors adopt independent front and rear speed closed-loop mode to prevent power loss
due to electronic differential when wheels are slipping in the air. Switching to off-road mode can
only be done after the chassis is completely stationary.
Command CAN upgrade bus silent mode setting command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Decision-making
and control unit
Node for the
chassis
0x422 None None
Data length 0x01
Byte Meaning Data type Note
byte [0] Control mode unsigned int8
0x00 Exit CAN upgrade bus silent
mode
0x01 Enter CAN upgrade bus silent
mode
In CAN upgrade bus silent mode,
the chassis VCU pauses sending
CAN data to the bus for firmware
upgrade, and resumes data
feedback after exiting.
Command Off-road mode setting command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Decision-making
and control unit
Node for the
chassis
0x423 None None26/49
Sample data, the following data is only for testing.
In addition to the status of the chassis itself, its feedback information also includes the steering
angle and speed of the four wheels, the current of the motor, the encoder information, and the
temperature information.
The details of the protocol are as follows:
Feedback information of speed, current, and position of motor
Data length 0x01
Byte Meaning Data type Note
byte [0] Control mode unsigned int8
0x00 Chassis exits off-road mode
0x01 Chassis enters off-road mode
byte [0] byte [1] byte [2] byte [3] byte [4] byte [5] byte [6] byte [7]
0x00 0x96 0x00 0x00 0x00 0x00 0x00 0x00
Command High-speed feedback information frame for motor driver
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire
chassis
Decision-making
and control unit
0x251~0x254 20ms None
Data length 0x08
Byte Meaning Data type Note27/49
Feedback of temperature voltage and status of motor
byte [0]
byte [1]
High order
byte of motor
speed
Low order
byte of motor
speed
signed int16
The current speed of the motor,
whose unit is RPM (Revolutions Per
Minute)
byte [2]
byte [3]
High order
byte of motor
current
Low order
byte of motor
current
signed int16
The present current of the motor,
whose unit is 0.1 A
byte [4]
byte [5]
byte [6]
byte [7]
Highest order
byte of position
High order
byte of position
Low order
byte of position
Lowest order
byte of position
signed int32 The current position of the motor,
whose unit is the number of pulses
Command Low-speed information feedback frame for motor
driver
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire
chassis
Decision-making
and control unit
0x261~0x264 100ms None
Data length 0x08
Byte Meaning Data type Note28/49
Table 2 Driver status
byte [0]
High order
byte of driver
voltage
unsigned int16
The current driver voltage, whose
unit is 0.1 V
byte [1]
Low order
byte of driver
voltage
byte [2]
High order
byte of drive
temperature
signed int16 The unit is 1 ℃.
byte [3]
Low order
byte of
driver temperatur
e
byte [4]
Motor
temperature
signed int8 The unit is 1 ℃.
byte [5] Driver status unsigned int8 See Table 2 for details
byte [6] Reserved - 0X00
byte [7] Reserved - 0X00
Byte Bit Meaning
byte[5] bit[0] Power supply voltage status (0: normal; 1: too low)
bit[1] Motor temperature status (0: normal; 1: over temperature)
bit[2] The current status of the driver(0: normal; 1: over-current)
bit[3] Driver temperature status (0: normal; 1: over temperature)29/49
Steering zero point setting and feedback commands are used to calibrate the zero point. The
details of the protocol are as follows:
Steering zero point setting command
Steering zero point setting feedback command
bit[4] Sensor status (0: Normal; 1: Abnormal)
bit[5] Driver status (0: Normal; 1: Abnormal)
bit[6] Drive enable status (0: disable; 1: enable)
bit[7] Reserved
Command Steering zero point setting command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Decision-making
and control unit
Node for the
chassis
0×431 None None
Data length 0×01
Byte Meaning Data type Note
Byte [0]
Set the current
position as the
zero point
unsigned int8
Set the current position as zero
point, the fixed value: 0xAA
Command Steering zero point setting feedback command
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Node for the
chassis
Decision-making
and control unit
0×43A None None
Data length 0×0130/49
Steering angle feedback
Byte Meaning Data type Note
Byte [0]
Set the current
position as the
zero point
unsigned int8
0xEE set the current position to
zero point successfully
Command Information feedback frame of steering angle
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire
chassis
Decision-making
and control unit
0x271 20ms None
Data length 0x08
Byte Meaning Data type Note
byte [0]
byte [1]
High order byte
of front steering
inner turn angle
Low order byte
of front steering
inner turn angle
signed int16 Current steering angle, unit 0.001rad
byte [2]
byte [3]
High order byte
of rear steering
inner turn angle
Low order byte
of rear steering
inner turn angle
signed int16 Current steering angle, unit 0.001rad
byte [4]
byte [5]
Reserved - 0X0031/49
Rotational speed feedback
Due to the adoption of a drive axle in the chassis, the front wheel speed is actually the drive shaft
speed, which can be understood as the average of the front left and front right wheel speeds. The
same applies to the rear wheels.
byte [6]
byte [7]
Reserved - 0X00
Command Information feedback frame of rotational speed
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire
chassis
Decision-making
and control unit
0x281 20ms None
Data length 0x08
Byte Meaning Data type Note
byte [0]
byte [1]
High order byte
of front wheel
rotational speed
Low order byte
of front wheel
rotational speed
signed int16
The current rotational speed,
whose unit is mm/s
byte [2]
byte [3]
High order byte
of rear wheel
rotational speed
Low order byte
of rear wheel
rotational speed
signed int16
The current rotational speed,
whose unit is mm/s
byte [4]
byte [5]
Reserved - 0X0032/49
Odometer information feedback frame is as follows
byte [6]
byte [7]
Reserved - 0X00
Command Odometer information feedback
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire
chassis
Decision-making
and control unit
0×311 20ms None
Data length 0x08
Byte Meaning Data type Note
byte [0]
byte [1]
byte [2]
byte [3]
Front wheel
odometer
highest byte
Front wheel
odometer
second highest
byte
Front wheel
odometer
second lowest
byte
Front wheel
odometer lowest
byte
signed int32
Chassis front wheel odometer
feedback,
Unit: mm33/49
The remote control information feedback frame is as follows
byte [4]
byte [5]
byte [6]
byte [7]
Rear wheel
odometer
highest byte
Rear wheel
odometer
second highest
byte
Rear wheel
odometer
second lowest
byte
Rear wheel
odometer lowest
byte
signed int32
Chassis rear wheel odometer
feedback,
Unit: mm
Command Remote control information feedback
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire
chassis
Decision-making
and control unit
0x241 20ms None
Data length 0x08
Byte Meaning Data type Note34/49
Battery BMS data feedback, and the details of the protocol are as follows
byte [0]
Remote control
SW feedback
unsigned int8
bit[0-1]: SWA: 2-Upper gear, 3-
Lower gear
bit[2-3]: SWB: 2-Upper gear, 1-
Middle gear, 3-Lower gear
bit[4-5]: SWC: 2-Upper gear, 1-
Middle gear, 3-Lower gear
bit[6-7]: SWD: 2-Upper gear, 3-
Lower gear
byte [1]
Right joystick
left/right
unsigned int8 Value range: [-100,100]
byte [2]
Right joystick
up/down
unsigned int8 Value range: [-100,100]
byte [3]
Left joystick
up/down
unsigned int8 Value range: [-100,100]
byte [4]
Left
joystick left/right
unsigned int8 Value range: [-100,100]
byte [5] left knob VRA unsigned int8 Value range: [-100,100]
byte [6] Reserved -- 0x00
byte [7]
Counting
verification
unsigned int8 0-255 cycle count
Command The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)35/49
Drive-by-wire
chassis
Decision-making
and control unit
0x361 500ms None
Data length 0x08
Byte Meaning Data type Note
byte [0]
Battery SOC
(State of
Charge)
unsigned int8 Range 0~100
byte [1]
Battery
SOH (State of
Health)
unsigned int8 Range 0~100
byte [2]
byte [3]
High order byte
of battery voltage
Low order byte
of battery voltage
unsigned int16 Unit: 0.01 V
byte [4]
byte [5]
High order byte
of battery current
Low order byte
of battery current
signed int16 Unit: 0.1 A
byte [6]
byte [7]
High order byte
of battery
temperature
Low order byte
of battery
temperature
signed int16 Unit: 0.1 ℃36/49
The feedback data of BMS for No. 1 battery
Command
The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)
Drive-by-wire
chassis
Decision-making
and control unit
0x362 500ms None
Data length 0x04
Byte Meaning Data type Note
byte [0] Alarm Status 1 unsigned int8
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [1] Alarm Status 2 unsigned int8 BIT0: Charging overcurrent
byte [2] Warning Status 1 unsigned int8
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [3] Warning Status 2 unsigned int8 BIT0: Charging overcurrent
Command The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)37/49
Drive-by-wire
chassis
Decision-
making and
control unit
0x363 500ms None
Data length 0x08
Byte Meaning Data type Note
byte [0] Battery SOC unsigned int8 Range 0~100
byte [1] Battery SOH unsigned int8 Range 0~100
byte [2]
byte [3]
High order byte
of battery voltage
Low order byte
of battery voltage
unsigned int16 Unit: 0.01 V
byte [4]
byte [5]
High order byte
of battery current
Low order byte
of battery current
signed int16 Unit: 0.1 A
byte [6]
byte [7]
High order byte
of battery
temperature
Low order byte
of battery
temperature
signed int16 Unit: 0.1 ℃
Command
The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)38/49
The feedback data of BMS for No. 2 battery
Drive-by-wire
chassis
Decision-
making and
control unit
0x364 500ms None
Data length 0x04
Byte Meaning Data type Note
byte [0] Alarm Status 1 unsigned int8
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [1] Alarm Status 2 unsigned int8 BIT0: Charging overcurrent
byte [2] Warning Status 1 unsigned int8
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [3] Warning Status 2 unsigned int8 BIT0: Charging overcurrent
Command The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)39/49
Drive-by-wire
chassis
Decision-
making and
control unit
0x365 500ms None
Data length 0x08
Byte Meaning Data type Note
byte [0] Battery SOC unsigned int8 Range 0~100
byte [1] Battery SOH unsigned int8 Range 0~100
byte [2]
byte [3]
High order byte
of battery voltage
Low order byte
of battery voltage
unsigned int16 Unit: 0.01 V
byte [4]
byte [5]
High order byte
of battery current
Low order byte
of battery current
signed int16 Unit: 0.1 A
byte [6]
byte [7]
High order byte
of battery
temperature
Low order byte
of battery
temperature
signed int16 Unit: 0.1 ℃
Command
The feedback data of BMS
Node for sending
Node for
receiving
ID Period (ms) Receive timeout
(ms)40/49
3.3 TITAN use manual for ROS
Drive-by-wire
chassis
Decision-
making and
control unit
0x366 500ms None
Data length 0x04
Byte Meaning Data type Note
byte [0] Alarm Status 1 unsigned int8
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [1] Alarm Status 2 unsigned int8 BIT0: Charging overcurrent
byte [2] Warning Status 1 unsigned int8
BIT1: Overvoltage; BIT2:
Undervoltage; BIT3: High
temperature; BIT4: Low
temperature; BIT7: Discharge
overcurrent
byte [3] Warning Status 2 unsigned int8 BIT0: Charging overcurrent41/49
ROS (Robot Operating System) provides some standard operating system services, such as
hardware abstraction, low-level device control, implementation of commonly used functionality,
message-passing between processes, and package management. ROS is based on a graph
architecture, where processing takes place in nodes that may receive, post, and multiplex various
information (such as sensor data, control, state, planning, and other messages). Currently ROS
mainly supports UBUNTU OS.
Development Preparation
Hardware Preparation
CANlight CAN communication module X1
Laptop X1
AGILEX TITAN mobile robot chassis X1
AGILEX supporting remote controller FS-i6s X1
Aviation connector on the rear of the AGILEX TITAN X1
使用示例环境说明
Ubuntu 18.04 LTS
ROS
Git
Hardware Connection and Preparation
Pull out the CAN wires of the circular connector on the rear of TITAN, and connect can_H and
can_L wires of the CAN to the CAN_TO_USB adapter; power on the TITAN; connect the
CAN_TO_USB adapter to the USB port of the laptop. The wiring diagram is shown in the figure
below.
The CAN wiring diagram
●
●
●
●
●
●
●
●42/49
ROS Installation and Environment Setup
Please refer to http://wiki.ros.org/kinetic/Installation/Ubuntu for details.
Test the Communication between CANABLE hardware and CAN
Set the CAN-TO-USB adapter
Enable the gs_usb kernel module
Set baud rate to 500k and enable the CAN-TO-USB adapter
If there is no error in the previous steps, you can check the CAN devices with the command
below
Install and use can-utils to test hardware
If the CAN-TO-USB adapter has been connected to the TITAN and the TITAN has been
powered on, the command below can be used to monitor the data from the TITAN.
●
sudo modprobe gs_usb
●
sudo ip link set can0 up type can bitrate 500000
●
ifconfifig -a
●
sudo apt install can-utils
●
candump can043/49
Please refer to:
[1] https://github.com/agilexrobotics/agx_sdk
[2] https://wiki.rdu.im/_pages/Notes/Embedded-System/-Linux/can-bus-in-linux.html
3.4 The Github ROS development kit and user manual
TITAN_base::An important ROS node for sending and receiving CAN messages, using topics
to control the movement of the TITAN, and read its status, which is based on the
ROS communication architecture.
TITAN_msgs:Define the message format of the topic for TITAN status feedback
TITAN_bringup:The startup file of the TITAN node and the keyboard_control node, and the script
to enable the USB_TO_CAN module
Send commands to control the TITAN through the keyboard:
1. Run the TITAN node
Note that the Agilex USB_TO_CAN module needs to be enabled before running the RANGER
node. The command is as follows: rosrun TITAN_bringup bringup_can2usb.bash. This command
only needs to be executed once after the USB_TO_CAN module is powered on.
2. Run the keyboard_control node
Please pay attention to check the output of the terminal, and use the specific keys to control the
movement of TITAN
3.5 Firmware Upgrade
●
roslaunch titan_bringup titan_minimal.launch
roslaunch titan_bringup titan_teleop_keyboard.launch44/49
To facilitate users to upgrade the firmware of the 4WD chassis and bring customers a better
experience, the TITAN chassis provides a hardware interface and a software for upgrading
firmware. The GUI (Graphical User Interface) of the software is shown in the figure below.
Upgrade Preparation
Agilex CAN debugging module X 1
Micro USB cable X 1
TITAN chassis X 1
A computer (WINDOWS OS (Operating System)) X 1
Upgrade Process
1.Plug in the USBTOCAN module on the computer, and then open the
AgxCandoUpgradeToolV1.3_boxed.exe software (the sequence cannot be wrong, first open the
software and then plug in the module, the device will not be recognized).
2.Click the Open Serial button, and then press the power button on the car body. If the connection
is successful, the version information of the main control will be recognized, as shown in the figure.
●
●
●
●45/49
3.Click the Load Firmware File button to load the firmware to be upgraded. If the loading is
successful, the firmware information will be obtained, as shown in the figure
4.Click the node to be upgraded in the node list box, and then click Start Upgrade Firmware to
start upgrading the firmware. After the upgrade is successful, a pop-up box will prompt.46/49
3.6 The vehicle body coordinate system47/49
The vehicle body coordinate system is defined as follows: the center of the vehicle is the origin,
the positive direction of the X-axis points to the front of the vehicle, the positive direction of the Y-
axis points to the left side of the vehicle, and the positive direction of the Z-axis points upwards.
4 Maintenance Instructions
4.1 Maintenance method
The vehicle maintenance
When the tires are severely worn, please replace them in time.
Battery maintenance
If the battery is not used for a long time, please don't forget to charge it every 2 to 3 months.
5 Product Size48/4949/49Identifikace uložené verze
SHA-256: 8f5bfa984d79fe2452a39640fe997b2a79a5d0d64aff153468061dc2331fff75