Produkty
Zjištění k produktu
Včetně historie změn
AgileX Bunker Prosource parameterDoložený údaj
Track Width | 150mm
Track Width 150mm
Zdroj: indrorobotics.ca ↗ Reviewed source parameter
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/bunker-pro/
- Místo v podkladu
- Reviewed source parameter
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker Prosource parameterDoložený údaj
Obstacle Clearance | 180mm
Obstacle Clearance 180mm
Zdroj: indrorobotics.ca ↗ Reviewed source parameter
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/bunker-pro/
- Místo v podkladu
- Reviewed source parameter
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
open area for remote control, because the vehicle itself does not have any
automatic obstacle avoidance sensors.
● Use in an ambient temperature of -20℃-60℃.
● If the vehicle does not individually customize the IP protection level, its water-proof and dust-
proof capacity is IP66.
Check
● Ensure that each equipment has enough charge.
● Ensure that the vehicle has no obvious abnormalities.
● Check if the battery of the remote control has enough charge.
● Make sure that the emergency stop switch has been released when using.
Operation
● Ensure that the surrounding area is relatively open during operation.
● Remote control within the line of sight.
● The maximum load of BUNKERPRO is 120KG. When in use, ensure that the payload does not
exceed 120KG.
● When installing an external extension for BUNKERPRO, confirm the center of mass of the
extension and make sure it is at the center of rotation.
’
● When the equipment s voltage is lower than 48V, please charge it in time.
● When the equipment is abnormal, please stop using it immediately to avoid secondary damage.
● When the equipment is abnormal, please contact the relevant technical personnel and do not
handle it without authorization.
3 / 35
● Please use it in an environment that meets the requirements of the protection level according to
the IP protection level of the equipment.
● Do not push the vehicle directly.
● When charging, make sure that the ambient temperature is greater than 0°C.
Maintenance
● Regularly check the tension of the suspended track, and tighten the track every 150~200H.
● After every 500 hours of operation, chec
open area for remote control, because the vehicle itself does not have any
automatic obstacle avoidance sensors.
● Use in an ambient temperature of -20℃-60℃.
● If the vehicle does not individually customize the IP protection level, its water-proof and dust-
proof capacity is IP66.
Check
● Ensure that each equipment has enough charge.
● Ensure that the vehicle has no obvious abnormalities.
● Check if the battery of the remote control has enough charge.
● Make sure that the emergency stop switch has been released when using.
Operation
● Ensure that the surrounding area is relatively open during operation.
● Remote control within the line of sight.
● The maximum load of BUNKERPRO is 120KG. When in use, ensure that the payload does not
exceed 120KG.
● When installing an external extension for BUNKERPRO, confirm the center of mass of the
extension and make sure it is at the center of rotation.
’
● When the equipment s voltage is lower than 48V, please charge it in time.
● When the equipment is abnormal, please stop using it immediately to avoid secondary damage.
● When the equipment is abnormal, please contact the relevant technical personnel and do not
handle it without authorization.
3 / 35
● Please use it in an environment that meets the requirements of the protection level according to
the IP protection level of the equipment.
● Do not push the vehicle directly.
● When charging, make sure that the ambient temperature is greater than 0°C.
Maintenance
● Regularly check the tension of the suspended track, and tighten the track every 150~200H.
● After every 500 hours of operation, chec
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 3400-5100
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 3400-5100
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
2.0 and bring to
customers more perfect experience, BUNKER MINI 2.0 provides the hardware interface for
firmware upgrade and the corresponding client software.
Upgrade Preparation
● Agilex CAN debugging module X 1
● Micro USB cable X 1
● BUNKER PRO chassis X 1
● A computer (WINDOWS OS (Operating System)) X 1
Upgrade Process
1.Plug in the USBTOCAN module on the computer, and then open the
AgxCandoUpgradeToolV1.3_boxed.exe software (the sequence cannot be wrong, first open the
software and then plug in the module, the device will not be recognized).
2.Click the Open Serial button, and then press the power button on the car body. If the connection
is successful, the version information of the main control will be recognized, as shown in the figure.
26 / 35
3.Click the Load Firmware File button to load the firmware to be upgraded. If the loading is
successful, the firmware information will be obtained, as shown in the figure
27 / 35
4.Click the node to be upgraded in the node list box, and then click Start Upgrade Firmware to
start upgrading the firmware. After the upgrade is successful, a pop-up box will prompt.
28 / 35
3.5 BUNKERPRO ROS Package Use Example
ROS provides some standard operating system services, such as hardware abstraction, low-level
equipment control,
2.0 and bring to
customers more perfect experience, BUNKER MINI 2.0 provides the hardware interface for
firmware upgrade and the corresponding client software.
Upgrade Preparation
● Agilex CAN debugging module X 1
● Micro USB cable X 1
● BUNKER PRO chassis X 1
● A computer (WINDOWS OS (Operating System)) X 1
Upgrade Process
1.Plug in the USBTOCAN module on the computer, and then open the
AgxCandoUpgradeToolV1.3_boxed.exe software (the sequence cannot be wrong, first open the
software and then plug in the module, the device will not be recognized).
2.Click the Open Serial button, and then press the power button on the car body. If the connection
is successful, the version information of the main control will be recognized, as shown in the figure.
26 / 35
3.Click the Load Firmware File button to load the firmware to be upgraded. If the loading is
successful, the firmware information will be obtained, as shown in the figure
27 / 35
4.Click the node to be upgraded in the node list box, and then click Start Upgrade Firmware to
start upgrading the firmware. After the upgrade is successful, a pop-up box will prompt.
28 / 35
3.5 BUNKERPRO ROS Package Use Example
ROS provides some standard operating system services, such as hardware abstraction, low-level
equipment control,
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 42500-44200
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 42500-44200
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
ar electrical panel is
pressed; if it is not pressed, please press it and release it, then it is in the released state.
Startup
Press the power switch (Q2 in the electrical panel); under normal circumstances, the light of the
power switch will light up, and the voltmeter will display the battery voltage normally;
Check the battery voltage. If the voltage is greater than 48V, it means the battery voltage is
normal. If the voltage is lower than 48V, please charge; when the voltage is lower than 46V,
BUNKERPRO cannot move normally.
Shutdown
Press the power switch to cut off the power;
Basic operating procedures of remote control
After starting the BUNKERPRO robot chassis normally, start the remote control and select the
remote control mode to control the movement of the BUNKER PRO platform through the
remote control.
3.2 Charging
BUNKERPRO is equipped with a standard charger by default, which can meet the charging needs
of customers. The specific operating procedures of charging are as follows:
Make sure that the BUNKERPRO chassis is in a shutdown state. Before charging, please make
sure that Q2 (power switch) in the rear electrical console is turned off; insert the plug of the
charger into the Q3 charging interface in the rear electrical control panel;
Connect the charger to the power supply and turn on the charger switch to enter the charging
state.
When charging by default, there is no indicator light on the chassis. Whether it is charging or
not depends on the status indicator of the charger.
3.3 Development
●
●
●
●
●
●
●
●
●15/35
BUNKERPRO provides a CAN interface for the user's development, and the user can control the
vehicle
body through this interface.
The CAN comm
ar electrical panel is
pressed; if it is not pressed, please press it and release it, then it is in the released state.
Startup
Press the power switch (Q2 in the electrical panel); under normal circumstances, the light of the
power switch will light up, and the voltmeter will display the battery voltage normally;
Check the battery voltage. If the voltage is greater than 48V, it means the battery voltage is
normal. If the voltage is lower than 48V, please charge; when the voltage is lower than 46V,
BUNKERPRO cannot move normally.
Shutdown
Press the power switch to cut off the power;
Basic operating procedures of remote control
After starting the BUNKERPRO robot chassis normally, start the remote control and select the
remote control mode to control the movement of the BUNKER PRO platform through the
remote control.
3.2 Charging
BUNKERPRO is equipped with a standard charger by default, which can meet the charging needs
of customers. The specific operating procedures of charging are as follows:
Make sure that the BUNKERPRO chassis is in a shutdown state. Before charging, please make
sure that Q2 (power switch) in the rear electrical console is turned off; insert the plug of the
charger into the Q3 charging interface in the rear electrical control panel;
Connect the charger to the power supply and turn on the charger switch to enter the charging
state.
When charging by default, there is no indicator light on the chassis. Whether it is charging or
not depends on the status indicator of the charger.
3.3 Development
●
●
●
●
●
●
●
●
●15/35
BUNKERPRO provides a CAN interface for the user's development, and the user can control the
vehicle
body through this interface.
The CAN comm
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 64600-66300
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 64600-66300
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
byte [7]
0x00 0x96 0x00 0x00 0x00 0x00 0x00 0x00
2. The vehicle rotates at 0.2RAD/S
byte [0] byte [1] byte [2] byte [3] byte [4] byte [5] byte [6] byte [7]
0x00 0x00 0x00 0xc8 0x00 0x00 0x00 0x00
In addition to the chassis status information will be fed back, the chassis feedback information
also includes motor data and sensor data.
Table 3.7 Motor Speed Current Position Information Feedback
Command Name Motor Drive High Speed Information Feedback Frame
Receive timeout
Sending node Receiving node ID Cycle (ms)
(ms)
Decision-
Steer-by- wire
making 0x251~0x254 20ms None
chassis
control unit
Data length 0x08
20 / 35
Position Function Data type Description
8-bit high motor
byte [0]
speed Current motor speed
signed int16
8-bit low motor
byte [7]
0x00 0x96 0x00 0x00 0x00 0x00 0x00 0x00
2. The vehicle rotates at 0.2RAD/S
byte [0] byte [1] byte [2] byte [3] byte [4] byte [5] byte [6] byte [7]
0x00 0x00 0x00 0xc8 0x00 0x00 0x00 0x00
In addition to the chassis status information will be fed back, the chassis feedback information
also includes motor data and sensor data.
Table 3.7 Motor Speed Current Position Information Feedback
Command Name Motor Drive High Speed Information Feedback Frame
Receive timeout
Sending node Receiving node ID Cycle (ms)
(ms)
Decision-
Steer-by- wire
making 0x251~0x254 20ms None
chassis
control unit
Data length 0x08
20 / 35
Position Function Data type Description
8-bit high motor
byte [0]
speed Current motor speed
signed int16
8-bit low motor
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 32300-34000
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 32300-34000
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
ile vehicle according to the ISO 8855
standard as shown in Figure 2.4.
Figure 2.4 Schematic Diagram of Reference Coordinate System for Vehicle Body
As shown in Figure 2.4, the vehicle body of BUNKERPRO is parallel to the X axis of the
established reference coordinate system.
In the remote control mode, push the remote controller rocker S1 forward to move in the positive
direction of X, push S1 backward to move in the negative direction of When pushed to the
minimum value, the movement speed in the negative direction of the The car body rotates from
the positive direction of the X-axis to the negative direction of the Y-axis. When S2 is pushed to
the left to the maximum value, the counterclockwise rotation linear speed is the maximum. When
S2 is pushed to the right to the maximum value, the clockwise rotation linear motion is the
maximum speed. In the control command mode, the positive value of the linear speed means
moving in the positive direction of the X-axis, and the negative value of the linear speed means
moving in the negative direction of the The negative value of angular velocity means that the car
body moves from the positive direction of the X-axis to the negative direction of the Y-axis.
3 Use and Development
This section mainly introduces the basic operation and use of the BUNKERPRO platform, and how
to carry out the secondary development of the vehicle body through the external CAN interface
and the CAN bus protocol.14/35
3.1 Use and operation
Check
Check the condition of the vehicle body. Check if the vehicle body has obvious abnormalities; if
so, please contact after-sales support;
When using for the first time, confirm whether Q2 (power switch) in the re
ile vehicle according to the ISO 8855
standard as shown in Figure 2.4.
Figure 2.4 Schematic Diagram of Reference Coordinate System for Vehicle Body
As shown in Figure 2.4, the vehicle body of BUNKERPRO is parallel to the X axis of the
established reference coordinate system.
In the remote control mode, push the remote controller rocker S1 forward to move in the positive
direction of X, push S1 backward to move in the negative direction of When pushed to the
minimum value, the movement speed in the negative direction of the The car body rotates from
the positive direction of the X-axis to the negative direction of the Y-axis. When S2 is pushed to
the left to the maximum value, the counterclockwise rotation linear speed is the maximum. When
S2 is pushed to the right to the maximum value, the clockwise rotation linear motion is the
maximum speed. In the control command mode, the positive value of the linear speed means
moving in the positive direction of the X-axis, and the negative value of the linear speed means
moving in the negative direction of the The negative value of angular velocity means that the car
body moves from the positive direction of the X-axis to the negative direction of the Y-axis.
3 Use and Development
This section mainly introduces the basic operation and use of the BUNKERPRO platform, and how
to carry out the secondary development of the vehicle body through the external CAN interface
and the CAN bus protocol.14/35
3.1 Use and operation
Check
Check the condition of the vehicle body. Check if the vehicle body has obvious abnormalities; if
so, please contact after-sales support;
When using for the first time, confirm whether Q2 (power switch) in the re
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 62900-64600
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 62900-64600
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
BUNKER PRO User Manual
BUNKER PRO
AgileX Robotics Team
User Manual V.2.0.1 2023.09
Document version
Edited
No. Version Date Reviewer Notes
by
1 V1.0.0 2023/3/17 谢瑞亲 first draft
Add rendering image
2 V2.0.0 2023/09/02 谢瑞亲 Modify how to use ROS package
Document checking
1 / 35
Synchronized car parameter list
3 V2.0.1 2023/09/018 吴忠义 Added table 3.2 Fault information
description table
This chapter contains important safety information, before the robot is powered on for the first
time, any person or organization must read and understand this information before using the
device. If you have any questions about use, please contact us at support@agilex.ai . Please
followed and implement all assembly instructions and guidelines in the chapters of this manual,
which is very important. Particular attention should be paid to the text related to the warning signs.
Important Safety Information
The information in this manual does not include the design, installation and operation of a
complete robot application, nor does it include all peripherals that may affect the sa
BUNKER PRO User Manual
BUNKER PRO
AgileX Robotics Team
User Manual V.2.0.1 2023.09
Document version
Edited
No. Version Date Reviewer Notes
by
1 V1.0.0 2023/3/17 谢瑞亲 first draft
Add rendering image
2 V2.0.0 2023/09/02 谢瑞亲 Modify how to use ROS package
Document checking
1 / 35
Synchronized car parameter list
3 V2.0.1 2023/09/018 吴忠义 Added table 3.2 Fault information
description table
This chapter contains important safety information, before the robot is powered on for the first
time, any person or organization must read and understand this information before using the
device. If you have any questions about use, please contact us at support@agilex.ai . Please
followed and implement all assembly instructions and guidelines in the chapters of this manual,
which is very important. Particular attention should be paid to the text related to the warning signs.
Important Safety Information
The information in this manual does not include the design, installation and operation of a
complete robot application, nor does it include all peripherals that may affect the sa
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 0-1700
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 0-1700
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
mand mode, it still needs to
send the control mode setting command before responding to the speed command.
The status setting frame is used to clear system errors. The specific protocol content is shown in
Table 3.6.
Table 3.6 Status Setting Frame
Command Name Status Setting Command
Receive timeout
Sending node Receiving node ID Cycle (ms)
(ms)
Decision-making
Chassis node 0x441 None None
control unit
19 / 35
Data length 0x01
Position Function Data type Description
0x00 clear all errors
byte [0]
Error clearing
command
unsigned int8 ’
0x01 Clear motor 1 s error
0x02 Clear motor 2’s error
Note 3: Sample data; the following data is for testing purposes only
1. The vehicle advances at a speed of 0.15/S
byte [0] byte [1] byte [2] byte [3] byte [4] byte [5] byte [6]
mand mode, it still needs to
send the control mode setting command before responding to the speed command.
The status setting frame is used to clear system errors. The specific protocol content is shown in
Table 3.6.
Table 3.6 Status Setting Frame
Command Name Status Setting Command
Receive timeout
Sending node Receiving node ID Cycle (ms)
(ms)
Decision-making
Chassis node 0x441 None None
control unit
19 / 35
Data length 0x01
Position Function Data type Description
0x00 clear all errors
byte [0]
Error clearing
command
unsigned int8 ’
0x01 Clear motor 1 s error
0x02 Clear motor 2’s error
Note 3: Sample data; the following data is for testing purposes only
1. The vehicle advances at a speed of 0.15/S
byte [0] byte [1] byte [2] byte [3] byte [4] byte [5] byte [6]
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 30600-32300
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 30600-32300
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
N interface for the user's development, and the user can control the
vehicle
body through this interface.
The CAN communication standard in BUNKERPRO adopts the CAN2.0B standard; the
communication
baud rate is 500K, and the message format adopts the MOTOROLA format. The linear velocity of
the movement and the angular velocity of the rotation of the chassis can be controlled through the
external
CAN bus interface; BUNKERPRO will feedback the current movement status information and the
status
information of the BUNKERPRO chassis in real time.
The protocol includes system status feedback frame, movement control feedback frame, and
control frame. The content of the protocol is as follows:
The system status feedback command includes the current vehicle body status feedback, control
mode
status feedback, battery voltage feedback, and fault feedback. The content of the protocol is
shown in Table 3.1.
Table 3.1 Feedback Frame of BUNKERPRO Chassis System Status
Command Name System status feedback instruction
Receive timeout
Sending node Receiving node ID Cycle (ms)
(ms)
Steer-by-wire Decision-making
0x211 200ms None
chassis control unit
Data length 0x08
Position Function Data type Description
N interface for the user's development, and the user can control the
vehicle
body through this interface.
The CAN communication standard in BUNKERPRO adopts the CAN2.0B standard; the
communication
baud rate is 500K, and the message format adopts the MOTOROLA format. The linear velocity of
the movement and the angular velocity of the rotation of the chassis can be controlled through the
external
CAN bus interface; BUNKERPRO will feedback the current movement status information and the
status
information of the BUNKERPRO chassis in real time.
The protocol includes system status feedback frame, movement control feedback frame, and
control frame. The content of the protocol is as follows:
The system status feedback command includes the current vehicle body status feedback, control
mode
status feedback, battery voltage feedback, and fault feedback. The content of the protocol is
shown in Table 3.1.
Table 3.1 Feedback Frame of BUNKERPRO Chassis System Status
Command Name System status feedback instruction
Receive timeout
Sending node Receiving node ID Cycle (ms)
(ms)
Steer-by-wire Decision-making
0x211 200ms None
chassis control unit
Data length 0x08
Position Function Data type Description
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 20400-22100
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 20400-22100
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
um 30%; Please do not use it in an environment with corrosive and flammable gas
or in an environment near flammable substances;
● Do not store it around heating elements such as heaters or large coiled resistors;
● Except for the specially customized version (customized with IP protection level), BUNKER PRO
is not waterproof, so please do not use it in environments with rain, snow, or standing water;
● It is recommended that the altitude of the operational environment should not exceed 1000M;
● It is recommended that the temperature difference between day and night in the operational
environment should not exceed 25°C;
● Regularly inspect and maintain the track tension wheel.
Precautions for electrical external
● The current of the rear extension power supply should not exceed 10A, and the total power
should not exceed 480W;
Safety precautions
● In case of any doubts during use, please follow related instruction manual or consult related
technical personnel;
● Before use, pay attention to field condition, and avoid mis-operation that will cause personnel
safety problem;
● In case of emergencies, press down the emergency stop button and power off the equipment;
● Without technical support and permission, please do not personally modify the internal
equipment structure.
Other precautions
● Do not drop or put the vehicle upside down when carrying and setting up;
● For non-professionals, please do not disassemble the vehicle without permission.
CONTENTS
5 / 35
CONTENTS
Document version
Important Safety Information
Atten
um 30%; Please do not use it in an environment with corrosive and flammable gas
or in an environment near flammable substances;
● Do not store it around heating elements such as heaters or large coiled resistors;
● Except for the specially customized version (customized with IP protection level), BUNKER PRO
is not waterproof, so please do not use it in environments with rain, snow, or standing water;
● It is recommended that the altitude of the operational environment should not exceed 1000M;
● It is recommended that the temperature difference between day and night in the operational
environment should not exceed 25°C;
● Regularly inspect and maintain the track tension wheel.
Precautions for electrical external
● The current of the rear extension power supply should not exceed 10A, and the total power
should not exceed 480W;
Safety precautions
● In case of any doubts during use, please follow related instruction manual or consult related
technical personnel;
● Before use, pay attention to field condition, and avoid mis-operation that will cause personnel
safety problem;
● In case of emergencies, press down the emergency stop button and power off the equipment;
● Without technical support and permission, please do not personally modify the internal
equipment structure.
Other precautions
● Do not drop or put the vehicle upside down when carrying and setting up;
● For non-professionals, please do not disassemble the vehicle without permission.
CONTENTS
5 / 35
CONTENTS
Document version
Important Safety Information
Atten
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 6800-8500
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 6800-8500
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
signed int8
0~255 cycle count; every time an
instruction is sent,
the count will increase once
Description of Fault Information
Byte Bit Meaning
byte [5] bit [0] Battery undervoltage fault
bit [1] Battery undervoltage warning
bit [2]
Remote control disconnection protection (0: normal, 1:
remote control disconnection)
bit [3] No.1 motor communication failure (0: No failure 1: Failure)
bit [4] No.2 motor communication failure (0: No failure 1: Failure)17/35
The command of movement control feedback frame includes the feedback of current linear
velocity and angular velocity of moving vehicle body. The specific protocol content is shown in
Table 3.3.
Table 3.3 Movement Control Feedback Frame
bit [5] Reserved, default 0
bit [6] Reserved, default 0
bit [7] Reserved, default 0
Command Name Movement Control Feedback Command
Sending node Receiving node ID Cycle(ms) Receive timeout
(ms)
Steer-by-wire
chassis
Decision-making
control unit
0x221 20ms None
Data length 0x08
Position Function Data type Description
byte [0]
8-bit high
moving speed
signed int16
Actual speed × 1000 (with an
accuracy of 0.001m/s)
byte [1]
8-bit low
moving speed
byte [2]
8-bit high
rotation speed
signed int16
Actual speed × 1000 (with an
accuracy of 0.001rad/s)
byte [3]
8-bit low
rotation speed
byte [4] Reserved - 0x00
byte [5] Reserved - 0x0018/35
The control frame includes linear velocity control opening, angular velocity control opening and
check sum. The specific content of the protocol is shown in Table 3.4.
Table 3.4 Movement Control Frame
byte [6] Reserved - 0x00
byte [7] Reserved - 0x00
Command Name Control Instruction
Sending node Receiving node ID Cycle (ms)
Receive timeout
(ms)
Decision-making
c
signed int8
0~255 cycle count; every time an
instruction is sent,
the count will increase once
Description of Fault Information
Byte Bit Meaning
byte [5] bit [0] Battery undervoltage fault
bit [1] Battery undervoltage warning
bit [2]
Remote control disconnection protection (0: normal, 1:
remote control disconnection)
bit [3] No.1 motor communication failure (0: No failure 1: Failure)
bit [4] No.2 motor communication failure (0: No failure 1: Failure)17/35
The command of movement control feedback frame includes the feedback of current linear
velocity and angular velocity of moving vehicle body. The specific protocol content is shown in
Table 3.3.
Table 3.3 Movement Control Feedback Frame
bit [5] Reserved, default 0
bit [6] Reserved, default 0
bit [7] Reserved, default 0
Command Name Movement Control Feedback Command
Sending node Receiving node ID Cycle(ms) Receive timeout
(ms)
Steer-by-wire
chassis
Decision-making
control unit
0x221 20ms None
Data length 0x08
Position Function Data type Description
byte [0]
8-bit high
moving speed
signed int16
Actual speed × 1000 (with an
accuracy of 0.001m/s)
byte [1]
8-bit low
moving speed
byte [2]
8-bit high
rotation speed
signed int16
Actual speed × 1000 (with an
accuracy of 0.001rad/s)
byte [3]
8-bit low
rotation speed
byte [4] Reserved - 0x00
byte [5] Reserved - 0x0018/35
The control frame includes linear velocity control opening, angular velocity control opening and
check sum. The specific content of the protocol is shown in Table 3.4.
Table 3.4 Movement Control Frame
byte [6] Reserved - 0x00
byte [7] Reserved - 0x00
Command Name Control Instruction
Sending node Receiving node ID Cycle (ms)
Receive timeout
(ms)
Decision-making
c
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 68000-69700
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 68000-69700
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
benefits > | tech specs > | media > | documentation and downloads >
bunker pro
BUNKER Pro is a heavy duty robot that boasts superb off-road performance and high-level IP67. The multi advanced suspension systems and reinforced shock absorbers bring it a unique anti-collision design to tackle challenging real-world terrains.
heavy duty robot bunker pro
key benefits of bunker pro
off-road performance
IP67 IEC Ingress Rating
Heavy duty robots are well-suited for off-road operations. Bunker Pro can traverse obstacles such as rocks, mud, sand, or even stairs. It has the ability to maintain traction and distribute weight over a larger surface area which enables them to handle rugged terrains effectively.
strength and payload
120kg Payload Capacity
Designed to handle substantial loads and perform tasks requiring high strength, Bunker Pro can lift, carry, and manipulate heavy objects or equipment that may be beyond the capabilities of human operators. This capability is particularly valuable in industries such as manufacturing, construction, logistics, and mining.
easily maneuverable
On The Spot Rotation
Although Bunker Pro is a heavy duty robot, it can rotate on the spot by driving the tracks in opposite directions, enabling them to turn within a tight radius. This maneuverability is ideal in confined spaces or when precise positioning is required. The tracks allow it to move with agility, precision, and control.
bunker pro technical drawings
robot development kits
473mm high
1064mm long
845mm wide
bunker pro specifications
Dimensions 1064L x 845W x 473H mm
IEC Ingress Rating IP67
Weight 150kg
Track Width 150mm
Payload Capacity 120kg
Top Speed 5.4km/h
Runtime 3 Hours
Charg
benefits > | tech specs > | media > | documentation and downloads >
bunker pro
BUNKER Pro is a heavy duty robot that boasts superb off-road performance and high-level IP67. The multi advanced suspension systems and reinforced shock absorbers bring it a unique anti-collision design to tackle challenging real-world terrains.
heavy duty robot bunker pro
key benefits of bunker pro
off-road performance
IP67 IEC Ingress Rating
Heavy duty robots are well-suited for off-road operations. Bunker Pro can traverse obstacles such as rocks, mud, sand, or even stairs. It has the ability to maintain traction and distribute weight over a larger surface area which enables them to handle rugged terrains effectively.
strength and payload
120kg Payload Capacity
Designed to handle substantial loads and perform tasks requiring high strength, Bunker Pro can lift, carry, and manipulate heavy objects or equipment that may be beyond the capabilities of human operators. This capability is particularly valuable in industries such as manufacturing, construction, logistics, and mining.
easily maneuverable
On The Spot Rotation
Although Bunker Pro is a heavy duty robot, it can rotate on the spot by driving the tracks in opposite directions, enabling them to turn within a tight radius. This maneuverability is ideal in confined spaces or when precise positioning is required. The tracks allow it to move with agility, precision, and control.
bunker pro technical drawings
robot development kits
473mm high
1064mm long
845mm wide
bunker pro specifications
Dimensions 1064L x 845W x 473H mm
IEC Ingress Rating IP67
Weight 150kg
Track Width 150mm
Payload Capacity 120kg
Top Speed 5.4km/h
Runtime 3 Hours
Charg
Zdroj: indrorobotics.ca ↗ Product source excerpt, characters 0-1700
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/bunker-pro/
- Místo v podkladu
- Product source excerpt, characters 0-1700
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
ormal circumstances, if BUNKERPRO can be controlled by the remote control, it means
that the
chassis movement control is normal; if it can receive the feedback frame of the chassis, it means
that the CAN extension link is normal. Please check whether the command is switched to can
control mode.
Q: When communicating through the CAN bus, the chassis feedback command is normal; but
why does the
vehicle not respond when issuing control?
A: BUNKERPRO has a communication protection mechanism inside. The chassis has a timeout
protection mechanism when processing CAN control commands from the outside. Suppose that
after the vehicle receives a frame of communication protocol, but it does not receive the next
frame of control command for more than 500MS, it will enter the communication protection, and
its speed is 0. Therefore, the commands from the host computer must be issued periodically.33/35
5 Product Dimensions
5.1 Illustration diagram of product dimensions34/35
5.2 Illustration diagram of top extended support dimensions35/35
ormal circumstances, if BUNKERPRO can be controlled by the remote control, it means
that the
chassis movement control is normal; if it can receive the feedback frame of the chassis, it means
that the CAN extension link is normal. Please check whether the command is switched to can
control mode.
Q: When communicating through the CAN bus, the chassis feedback command is normal; but
why does the
vehicle not respond when issuing control?
A: BUNKERPRO has a communication protection mechanism inside. The chassis has a timeout
protection mechanism when processing CAN control commands from the outside. Suppose that
after the vehicle receives a frame of communication protocol, but it does not receive the next
frame of control command for more than 500MS, it will enter the communication protection, and
its speed is 0. Therefore, the commands from the host computer must be issued periodically.33/35
5 Product Dimensions
5.1 Illustration diagram of product dimensions34/35
5.2 Illustration diagram of top extended support dimensions35/35
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 81600-82642
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 81600-82642
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker Prosource parameterDoložený údaj
Payload Capacity | 120kg
Payload Capacity 120kg
Zdroj: indrorobotics.ca ↗ Reviewed source parameter
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/bunker-pro/
- Místo v podkladu
- Reviewed source parameter
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker Prosource parameterDoložený údaj
IEC Ingress Rating | IP67
IEC Ingress Rating IP67
Zdroj: indrorobotics.ca ↗ Reviewed source parameter
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/bunker-pro/
- Místo v podkladu
- Reviewed source parameter
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
or higher than 60℃;
●
●
●
●
●
●
●
●
●
●
●5/35
The relative humidity requirements of BUNKERPRO's operational environment are: maximum
80%, minimum 30%; Please do not use it in an environment with corrosive and flammable gas
or in an environment near flammable substances;
Do not store it around heating elements such as heaters or large coiled resistors;
Except for the specially customized version (customized with IP protection level), BUNKER PRO
is not waterproof, so please do not use it in environments with rain, snow, or standing water;
It is recommended that the altitude of the operational environment should not exceed 1000M;
It is recommended that the temperature difference between day and night in the operational
environment should not exceed 25°C;
Regularly inspect and maintain the track tension wheel.
Precautions for electrical external
The current of the rear extension power supply should not exceed 10A, and the total power
should not exceed 480W;
Safety precautions
In case of any doubts during use, please follow related instruction manual or consult related
technical personnel;
Before use, pay attention to field condition, and avoid mis-operation that will cause personnel
safety problem;
In case of emergencies, press down the emergency stop button and power off the equipment;
Without technical support and permission, please do not personally modify the internal
equipment structure.
Other precautions
Do not drop or put the vehicle upside down when carrying and setting up;
For non-professionals, please do not disassemble the vehicle without permission.
CONTENTS
●
●
●
●
●
●
●
●
●
●
●
●
●6/35
CONTENTS
Document version
Important Safety Information
Attention
or higher than 60℃;
●
●
●
●
●
●
●
●
●
●
●5/35
The relative humidity requirements of BUNKERPRO's operational environment are: maximum
80%, minimum 30%; Please do not use it in an environment with corrosive and flammable gas
or in an environment near flammable substances;
Do not store it around heating elements such as heaters or large coiled resistors;
Except for the specially customized version (customized with IP protection level), BUNKER PRO
is not waterproof, so please do not use it in environments with rain, snow, or standing water;
It is recommended that the altitude of the operational environment should not exceed 1000M;
It is recommended that the temperature difference between day and night in the operational
environment should not exceed 25°C;
Regularly inspect and maintain the track tension wheel.
Precautions for electrical external
The current of the rear extension power supply should not exceed 10A, and the total power
should not exceed 480W;
Safety precautions
In case of any doubts during use, please follow related instruction manual or consult related
technical personnel;
Before use, pay attention to field condition, and avoid mis-operation that will cause personnel
safety problem;
In case of emergencies, press down the emergency stop button and power off the equipment;
Without technical support and permission, please do not personally modify the internal
equipment structure.
Other precautions
Do not drop or put the vehicle upside down when carrying and setting up;
For non-professionals, please do not disassemble the vehicle without permission.
CONTENTS
●
●
●
●
●
●
●
●
●
●
●
●
●6/35
CONTENTS
Document version
Important Safety Information
Attention
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 56100-57800
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 56100-57800
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
node Receiving node ID Cycle (ms)
(ms)
Decision-
Steer-by- wire
making 0x311 20ms None
chassis
control unit
Data length 0x08
Position Function Data type Description
Highest bit of
byte [0] left wheel
odometer
Second-highest
byte [1] bit of left wheel
odometer Chassis left wheel odometer
signed int32 feedback
Second-lowest Unit: mm
byte [2] bit of left wheel
odometer
Lowest bit of
byte [3] left
wheel odometer
Highest bit of signed int32 Chassis right wheel odometer
byte [4] right wheel feedback
odometer Unit: mm
Second-highest
byte [5] bit of right
wheel odometer
Second-lowest
byte [6] bit of right
wheel odometer
23 / 35
Lowest bit of
byte [7] right wheel
odometer
Table 3.11 Remote Control Information Feedback
Command Name Remote Control Information Feedback Frame
node Receiving node ID Cycle (ms)
(ms)
Decision-
Steer-by- wire
making 0x311 20ms None
chassis
control unit
Data length 0x08
Position Function Data type Description
Highest bit of
byte [0] left wheel
odometer
Second-highest
byte [1] bit of left wheel
odometer Chassis left wheel odometer
signed int32 feedback
Second-lowest Unit: mm
byte [2] bit of left wheel
odometer
Lowest bit of
byte [3] left
wheel odometer
Highest bit of signed int32 Chassis right wheel odometer
byte [4] right wheel feedback
odometer Unit: mm
Second-highest
byte [5] bit of right
wheel odometer
Second-lowest
byte [6] bit of right
wheel odometer
23 / 35
Lowest bit of
byte [7] right wheel
odometer
Table 3.11 Remote Control Information Feedback
Command Name Remote Control Information Feedback Frame
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 37400-39100
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 37400-39100
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
0x00 System in normal condition
Current status of
byte [0] unsigned int8 0x01 Emergency stop mode
vehicle body
0x02 System exception
15 / 35
0x00 Standby mode
byte [1] Mode control unsigned int8 0x01 CAN command control mode
0x03 Remote control mode
The battery
byte [2] voltage is
8 bits higher Actual voltage × 10 (with an
unsigned int16
accuracy of 0.1V)
The battery
byte [3] voltage is
eight bits lower
byte [4] Reserved - 0x0
Failure Refer to [Description of Fault
byte [5] unsigned int8
information Information]
byte [6] Reserved - 0X00
0~255 cycle count; every time an
Count check
byte [7] unsigned int8 instruction is sent,
(count)
the count will increase once
Table 3.2 Description of Faul
0x00 System in normal condition
Current status of
byte [0] unsigned int8 0x01 Emergency stop mode
vehicle body
0x02 System exception
15 / 35
0x00 Standby mode
byte [1] Mode control unsigned int8 0x01 CAN command control mode
0x03 Remote control mode
The battery
byte [2] voltage is
8 bits higher Actual voltage × 10 (with an
unsigned int16
accuracy of 0.1V)
The battery
byte [3] voltage is
eight bits lower
byte [4] Reserved - 0x0
Failure Refer to [Description of Fault
byte [5] unsigned int8
information Information]
byte [6] Reserved - 0X00
0~255 cycle count; every time an
Count check
byte [7] unsigned int8 instruction is sent,
(count)
the count will increase once
Table 3.2 Description of Faul
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 22100-23800
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 22100-23800
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
CAN bus high
4 CAN CAN_L CAN bus low
Figure 2.2 Pin Definition of the Rear Aviation Extension Interface
2.2 Instructions on remote control
Fs remote control is an optional accessory for BUNKER PRO products. Customers can choose
according to actual needs. Using the remote control can easily control the BUNKER PRO universal
robot chassis. In this product, we use the left-hand throttle design. Its definition and functions can
be referred to Figure 2.3. The functions of the buttons are defined as: SWA, SWB, SWC, SWD.
SWD is not activated yet, among them SWB is the control mode selection button, dialed to the top
is the command control mode, dialed to the middle is the remote control mode, S1 is the throttle
button, controls the BUNKER PRO to move forward and backward; S2 controls the rotation, and
POWER is the power supply Buttons, press and hold them at the same time to turn on. It should
be noted that when the remote control is turned on, SWA, SWB, SWC, and SWD all need to be at
the top.
11 / 35
Figure 2.3 Schematic diagram of the FS remote control buttons
Remote control interface description:
Bunker : model
Vol: battery voltage
Car: chassis status
Batt: Chassis power percentage
P: Park
Remoter: remote control battery level
Fault Code: Error information (Represents byte [5] in 211 frame)
12 / 35
2.3 Instructions on control demands and movements
We set up a coordinate reference system for ground mobile vehicle according to the ISO 8855
CAN bus high
4 CAN CAN_L CAN bus low
Figure 2.2 Pin Definition of the Rear Aviation Extension Interface
2.2 Instructions on remote control
Fs remote control is an optional accessory for BUNKER PRO products. Customers can choose
according to actual needs. Using the remote control can easily control the BUNKER PRO universal
robot chassis. In this product, we use the left-hand throttle design. Its definition and functions can
be referred to Figure 2.3. The functions of the buttons are defined as: SWA, SWB, SWC, SWD.
SWD is not activated yet, among them SWB is the control mode selection button, dialed to the top
is the command control mode, dialed to the middle is the remote control mode, S1 is the throttle
button, controls the BUNKER PRO to move forward and backward; S2 controls the rotation, and
POWER is the power supply Buttons, press and hold them at the same time to turn on. It should
be noted that when the remote control is turned on, SWA, SWB, SWC, and SWD all need to be at
the top.
11 / 35
Figure 2.3 Schematic diagram of the FS remote control buttons
Remote control interface description:
Bunker : model
Vol: battery voltage
Car: chassis status
Batt: Chassis power percentage
P: Park
Remoter: remote control battery level
Fault Code: Error information (Represents byte [5] in 211 frame)
12 / 35
2.3 Instructions on control demands and movements
We set up a coordinate reference system for ground mobile vehicle according to the ISO 8855
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 15300-17000
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 15300-17000
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
ontrol unit
Chassis node 0x111 20ms None
Data length 0x08
Position Function Data type Description
byte [0]
8-bit high linear
speed
signed int16
Moving speed of vehicle body , unit:
mm/s, range [-1700,1700]
byte [1]
8-bit low linear
speed
byte [2]
8-bit high
angular velocity
signed int16
Angular velocity of vehicle body
rotation, unit: 0.001rad/s, range
[- 3140,3140] byte [3]
8-bit low
angular velocity
byte [4] Reserved - 0x00
byte [5] Reserved - 0x00
byte [6] Reserved - 0x00
byte [7] Reserved - 0x0019/35
The mode setting frame is used to set the control interface of the terminal. The specific protocol
content is shown in Table 3.5
Table 3.5 Control Mode Setting Frame
Note [1] Description of control mode
When the remote control of BUNKERPRO is not powered on, the control mode is standby mode
by default, and you need to switch it to command mode to send movement control command. If
the remote control is turned on, the remote control has the highest authority and can shield the
control of commands. When the remote control is switched to the command mode, it still needs to
send the control mode setting command before responding to the speed command.
The status setting frame is used to clear system errors. The specific protocol content is shown in
Table 3.6.
Table 3.6 Status Setting Frame
Command Name Control Mode Setting Command
Sending node Receiving node ID Cycle (ms)
Receive timeout
(ms)
Decision-making
control unit
Chassis node 0x421 20ms 500ms
Data length 0x01
Position Function Data type Description
byte [0]
CAN control
enable
unsigned int8
0x00 Standby mode
0x01 CAN command mode enable
Command Name Status Setting Command
Sending node Receiving node ID Cycle (ms)
Re
ontrol unit
Chassis node 0x111 20ms None
Data length 0x08
Position Function Data type Description
byte [0]
8-bit high linear
speed
signed int16
Moving speed of vehicle body , unit:
mm/s, range [-1700,1700]
byte [1]
8-bit low linear
speed
byte [2]
8-bit high
angular velocity
signed int16
Angular velocity of vehicle body
rotation, unit: 0.001rad/s, range
[- 3140,3140] byte [3]
8-bit low
angular velocity
byte [4] Reserved - 0x00
byte [5] Reserved - 0x00
byte [6] Reserved - 0x00
byte [7] Reserved - 0x0019/35
The mode setting frame is used to set the control interface of the terminal. The specific protocol
content is shown in Table 3.5
Table 3.5 Control Mode Setting Frame
Note [1] Description of control mode
When the remote control of BUNKERPRO is not powered on, the control mode is standby mode
by default, and you need to switch it to command mode to send movement control command. If
the remote control is turned on, the remote control has the highest authority and can shield the
control of commands. When the remote control is switched to the command mode, it still needs to
send the control mode setting command before responding to the speed command.
The status setting frame is used to clear system errors. The specific protocol content is shown in
Table 3.6.
Table 3.6 Status Setting Frame
Command Name Control Mode Setting Command
Sending node Receiving node ID Cycle (ms)
Receive timeout
(ms)
Decision-making
control unit
Chassis node 0x421 20ms 500ms
Data length 0x01
Position Function Data type Description
byte [0]
CAN control
enable
unsigned int8
0x00 Standby mode
0x01 CAN command mode enable
Command Name Status Setting Command
Sending node Receiving node ID Cycle (ms)
Re
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 69700-71400
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 69700-71400
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
CONTENTS
1 Introduction to BUNKERPRO
1.1 Product list
1.2 Tech specifications
1.3 Requirement for development
2 The Basics
2.1Instructions on electrical interfaces
2.2 Instructions on remote control
2.3 Instructions on control demands and movements
3 Use and Development
3.1 Use and operation
3.2 Charging
3.3.2 CAN cable connection
3.3.3 Realization of CAN command control
3.4 Firmware upgrade
3.5 BUNKERPRO ROS Package Use Example
4 Q&A
5 Product Dimensions
5.1 Illustration diagram of product dimensions 7/35
1 Introduction to BUNKERPRO
BUNKERPRO is a tracked chassis vehicle for all-round industry applications. It has the
characteristics of simple and sensitive operation, large development space, suitable for
development and application in a variety of fields, independent suspension system, heavy-duty
shock absorption, strong climbing ability, and being able to climb stairs. It can be used for the
development of special robots such as robots for inspection and exploration, rescue and EOD,
special shooting, special transportation, etc., to solve robot movement solutions.
1.1 Product list
1.2 Tech specifications
5.2 Illustration diagram of top extended support dimensions
Name Quantity
BUNKER PRO Robot Body x1
Battery Charger(AC 220V) x1
Aviation male plug (4-Pin) x1
FS remote control transmitter(Optional) x1
USB to CAN communication module x1
Parameter Types Items Values
Mechanical specifications L × W × H (mm) 1064*845*473
Wheelbase (mm) -8/35
Front/rear wheel base (mm) -
Chassis height 120
Track width 150
Curb weight (kg) 180
Battery Type Lithium battery
Battery parameters 6
CONTENTS
1 Introduction to BUNKERPRO
1.1 Product list
1.2 Tech specifications
1.3 Requirement for development
2 The Basics
2.1Instructions on electrical interfaces
2.2 Instructions on remote control
2.3 Instructions on control demands and movements
3 Use and Development
3.1 Use and operation
3.2 Charging
3.3.2 CAN cable connection
3.3.3 Realization of CAN command control
3.4 Firmware upgrade
3.5 BUNKERPRO ROS Package Use Example
4 Q&A
5 Product Dimensions
5.1 Illustration diagram of product dimensions 7/35
1 Introduction to BUNKERPRO
BUNKERPRO is a tracked chassis vehicle for all-round industry applications. It has the
characteristics of simple and sensitive operation, large development space, suitable for
development and application in a variety of fields, independent suspension system, heavy-duty
shock absorption, strong climbing ability, and being able to climb stairs. It can be used for the
development of special robots such as robots for inspection and exploration, rescue and EOD,
special shooting, special transportation, etc., to solve robot movement solutions.
1.1 Product list
1.2 Tech specifications
5.2 Illustration diagram of top extended support dimensions
Name Quantity
BUNKER PRO Robot Body x1
Battery Charger(AC 220V) x1
Aviation male plug (4-Pin) x1
FS remote control transmitter(Optional) x1
USB to CAN communication module x1
Parameter Types Items Values
Mechanical specifications L × W × H (mm) 1064*845*473
Wheelbase (mm) -8/35
Front/rear wheel base (mm) -
Chassis height 120
Track width 150
Curb weight (kg) 180
Battery Type Lithium battery
Battery parameters 6
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 57800-59500
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 57800-59500
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
Drive motor reduction ratio :
1 7.5
Drive motor sensor Photoelectric increment 2500
Performance parameters IP Grade IP22
Maximum speed (km/h) 1.7m/s
Minimum turning radius
Can turn in place
(mm)
Maximum gradeability (°) 30°
Maximum obstacle crossing 180
8 / 35
Ground clearance (mm) 740
Maximum battery life (h) 8
Maximum distance (km) 15KM
Charging time (h) 4.5
Working temperature (℃) -10~60℃
Remote control Control
Control mode
Command control mode
Control
RC transmitter 2.4G/extreme distance 200M
System interface CAN
1.3 Requirement for development
BUNKERPRO is equipped with FS remote control at the factory, and users can control t
Drive motor reduction ratio :
1 7.5
Drive motor sensor Photoelectric increment 2500
Performance parameters IP Grade IP22
Maximum speed (km/h) 1.7m/s
Minimum turning radius
Can turn in place
(mm)
Maximum gradeability (°) 30°
Maximum obstacle crossing 180
8 / 35
Ground clearance (mm) 740
Maximum battery life (h) 8
Maximum distance (km) 15KM
Charging time (h) 4.5
Working temperature (℃) -10~60℃
Remote control Control
Control mode
Command control mode
Control
RC transmitter 2.4G/extreme distance 200M
System interface CAN
1.3 Requirement for development
BUNKERPRO is equipped with FS remote control at the factory, and users can control t
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 11900-13600
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 11900-13600
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
复制代码
roslaunch bunker_bringup bunker_robot_base.launch
● Start the keyboard remote operation node
复制代码
roslaunch bunker_bringup bunker_teleop_keyboard.launch
31 / 35
Github ROS development package directory and usage instructions
*_base:: The core node for the chassis to send and receive hierarchical CAN messages. Based on
the communication mechanism of ros, it can control the movement of the chassis and read the
status of the bunker through the topic.
*_msgs: Define the specific message format of the chassis status feedback topic
*_bringup: startup files for chassis nodes and keyboard control nodes, and scripts to enable the
usb_to_can module
4 Q&A
:
Q BUNKERPRO is started normally, but why does it not move when using the remote control to
control the vehicle body?
:
A First, confirm whether the power switch is pressed; and then, confirm whether the control
mode selected through the mode selection switch on the upper left side of the remote control is
correct.
Q: The BUNKERPRO remote control is normal; the chassis status and movement information
’ ’
feedback is normal; but why can t the vehicle body s control mode be switched, and why does
the chassis not respond to the control frame protocol when the control frame protocol is issued?
A: Under normal circumstances, if BUNKERPRO can be controlled by the remote control, it means
that the
chassis movement control is normal; if it can receive the feedback frame of the cha
复制代码
roslaunch bunker_bringup bunker_robot_base.launch
● Start the keyboard remote operation node
复制代码
roslaunch bunker_bringup bunker_teleop_keyboard.launch
31 / 35
Github ROS development package directory and usage instructions
*_base:: The core node for the chassis to send and receive hierarchical CAN messages. Based on
the communication mechanism of ros, it can control the movement of the chassis and read the
status of the bunker through the topic.
*_msgs: Define the specific message format of the chassis status feedback topic
*_bringup: startup files for chassis nodes and keyboard control nodes, and scripts to enable the
usb_to_can module
4 Q&A
:
Q BUNKERPRO is started normally, but why does it not move when using the remote control to
control the vehicle body?
:
A First, confirm whether the power switch is pressed; and then, confirm whether the control
mode selected through the mode selection switch on the upper left side of the remote control is
correct.
Q: The BUNKERPRO remote control is normal; the chassis status and movement information
’ ’
feedback is normal; but why can t the vehicle body s control mode be switched, and why does
the chassis not respond to the control frame protocol when the control frame protocol is issued?
A: Under normal circumstances, if BUNKERPRO can be controlled by the remote control, it means
that the
chassis movement control is normal; if it can receive the feedback frame of the cha
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 47600-49300
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 47600-49300
- Zaznamenání
- Ruční záznam · public-product-review-20261024
AgileX Bunker ProDalší doložená specifikaceDoložený údaj
0AH
Power drive motor 2×1500W Brushless servo motor
Steering drive motor -
Parking mode -
Steering Track type differential steering
Suspension form
Christie suspension + Matilda four-
wheel balance suspension
Steering motor reduction
ratio
-
Steering motor encoder -
Drive motor reduction ratio 1:7.5
Drive motor sensor Photoelectric increment 2500
Performance parameters IP Grade IP22
Maximum speed (km/h) 1.7m/s
Minimum turning radius
(mm)
Can turn in place
Maximum gradeability (°) 30°
Maximum obstacle crossing 1809/35
1.3 Requirement for development
BUNKERPRO is equipped with FS remote control at the factory, and users can control the
BUNKERPRO mobile robot chassis through remote control to complete the movement and
rotation operations; BUNKERPRO is equipped with CAN interface, and users can carry out
secondary development through it.
2 The Basics
This section will give a basic introduction to the BUNKERPRO mobile robot chassis, so that users
and developers have a basic understanding of the BUNKERPRO chassis.
2.1Instructions on electrical interfaces
Ground clearance (mm) 740
Maximum battery life (h) 8
Maximum distance (km) 15KM
Charging time (h) 4.5
Working temperature (℃) -10~60℃
Control
Control mode
Remote control Control
Command control mode
RC transmitter 2.4G/extreme distance 200M
System interface CAN10/35
The rear electrical interfaces are shown in Figure 2.1, where Q1 is the CAN and 48V power aviation
interface, Q2 is the power switch, Q3 is the charging interface, Q4 is the antenna, Q5 and Q6 are
respectively the driver debugging interface and the main control debugging interface (not open to
the outside), and Q7 is the power display interaction.
Figure 2.1 Rear
0AH
Power drive motor 2×1500W Brushless servo motor
Steering drive motor -
Parking mode -
Steering Track type differential steering
Suspension form
Christie suspension + Matilda four-
wheel balance suspension
Steering motor reduction
ratio
-
Steering motor encoder -
Drive motor reduction ratio 1:7.5
Drive motor sensor Photoelectric increment 2500
Performance parameters IP Grade IP22
Maximum speed (km/h) 1.7m/s
Minimum turning radius
(mm)
Can turn in place
Maximum gradeability (°) 30°
Maximum obstacle crossing 1809/35
1.3 Requirement for development
BUNKERPRO is equipped with FS remote control at the factory, and users can control the
BUNKERPRO mobile robot chassis through remote control to complete the movement and
rotation operations; BUNKERPRO is equipped with CAN interface, and users can carry out
secondary development through it.
2 The Basics
This section will give a basic introduction to the BUNKERPRO mobile robot chassis, so that users
and developers have a basic understanding of the BUNKERPRO chassis.
2.1Instructions on electrical interfaces
Ground clearance (mm) 740
Maximum battery life (h) 8
Maximum distance (km) 15KM
Charging time (h) 4.5
Working temperature (℃) -10~60℃
Control
Control mode
Remote control Control
Command control mode
RC transmitter 2.4G/extreme distance 200M
System interface CAN10/35
The rear electrical interfaces are shown in Figure 2.1, where Q1 is the CAN and 48V power aviation
interface, Q2 is the power switch, Q3 is the charging interface, Q4 is the antenna, Q5 and Q6 are
respectively the driver debugging interface and the main control debugging interface (not open to
the outside), and Q7 is the power display interaction.
Figure 2.1 Rear
Zdroj: indrorobotics.ca · PDF ↗ Product source excerpt, characters 59500-61200
Podrobnosti zjištění
- Zdroj
- https://indrorobotics.ca/wp-content/uploads/2024/07/bunker-pro-user-manual-en-1.pdf
- Místo v podkladu
- Product source excerpt, characters 59500-61200
- Zaznamenání
- Ruční záznam · public-product-review-20261024