← Přehled firem
Získáno 25. 10. 2026 · 00:32
Beltdraulic™ Railgate 5500
Beltdraulic™ Railgate                                         RISE Robotics




          OPERATORS MANUAL
     For 4500, 5500, and 6500 Beltdraulic Railgate Pre-Production Models




RISE Robotics                     1 of 33               www.riserobotics.com
MADE IN THE USA
Beltdraulic™ Railgate                   RISE Robotics




   QUICK START GUIDE




RISE Robotics           2 of 33   www.riserobotics.com
Beltdraulic™ Railgate                   RISE Robotics




RISE Robotics           3 of 33   www.riserobotics.com
Beltdraulic™ Railgate                                                                                             RISE Robotics




                  TABLE OF
                  CONTENTS
           Safety....................................................................................................5

           Nomenclature ...................................................................................11

           Operation ..........................................................................................14

           Maintenance .....................................................................................19

           Warranty ...........................................................................................26

           Troubleshooting .............................................................................28

           Inspection Record .........................................................................30

           Notes ..................................................................................................32




RISE Robotics                                              4 of 33                                   www.riserobotics.com
Beltdraulic™ Railgate                                                                             RISE Robotics


                  Safety                                   It is the responsibility of the installer/operator to
                                                           understand and perform proper operating
A restraining system may be necessary to secure            procedures. Be aware of the inherent dangers in
certain types of cargo on the liftgate platform,           the use of this product and the tools used to install
depending on the specific application, such as a           it. Read and understand all Danger, Warnings,
cart stop, retention ramp, fencing, or straps. This        Cautions, and Important Notices in this manual and
should be considered by the purchaser for their            on the liftgate or truck.
particular application to prevent the possibility of
severe personal injury or death due to cargo                                This is the safety alert symbol. It is
shifting and/or falling from the liftgate platform. All                     used to alert you to potential
operators must be fully trained and have read the                           personal injury hazards. Obey all
full operator's manual before operating the liftgate.                       safety messages that follow this
                                                                            symbol to avoid possible injury or
                                                                            death.

                                                           Th i s m a n u a l co n t a i n s DA N G E R S , SA F E T Y
                                                           I N S T R U C T I O N S , C A U T I O N S , I M P O R TA N T
                                                           NOTICES, and NOTES which must be followed to
                                                           prevent the possibility of improper service, damage
                                                           to the equipment, personal injury, or death. The
                                                           following keywords call the readers’ attention to
It is imperative to articulate the following, despite      potential hazards.
its apparent obviousness:
                                                           Hazards are identified by the “Safety Alert Symbol”
Only qualified personnel familiar with welding and         such as “DANGER”, “WARNING”, or “CAUTION”.
material handling equipment, such as forklifts,
should be authorized to install this liftgate.

If installers have any questions, they may contact
RISE Robotics at the contact information provided
on the last page of this document.




                                                           Note: This contains additional information
                                                           necessary to a procedure.


                                                           Most accidents involving the operation,
                                                           maintenance, or repair of products made by RISE



RISE Robotics                                        5 of 33                            www.riserobotics.com
Beltdraulic™ Railgate                                              RISE Robotics




Robotics occur because the owner/installer/
operator fails to observe safety precautions or
operating instructions. Accidents can often be
avoided by being alert and recognizing potentially
hazardous situations. Any individuals installing,
operating, repairing, or maintaining liftgates should
have the necessary training, skills, and tools to
perform these functions correctly and safely. The
safety information in this manual serves as a basic
guide to prevent injury or death.

The warnings in this manual and on the product
itself are not all-inclusive.

DO NOT proceed if any doubt arises about the
correct or safe method of performing anything
found in this or other RISE Robotics manuals. Seek
out expert assistance from a qualified person
before continuing.




Do not attempt to install, operate, or maintain our
product without fully understanding all precautions
and safety recommendations. Do not operate or
work on a truck or lift gate unless you have read
and understand the instructions and warnings in
the Installation Manual.




RISE Robotics                                      6 of 33   www.riserobotics.com
Beltdraulic™ Railgate                              RISE Robotics


                              Safety Icons




RISE Robotics           7 of 33              www.riserobotics.com
Beltdraulic™ Railgate                   RISE Robotics




RISE Robotics           8 of 33   www.riserobotics.com
Beltdraulic™ Railgate                                                                       RISE Robotics


Battery Safety                                           PRECAUTIONS:
                                                         ⚠ Qualified personnel must handle all product
Note: Read and follow all safety instructions for
handling the battery before servicing, installation,     work to reduce risk of electric shock.
or troubleshooting.
                                                         ⚠ Follow local and national electrical standards for
Lithium Iron Phosphate (LiFePO4) batteries are an
inherently safe chemistry. However, safety               installation and confirm utility provider and local
measures should always be taken into                     authority requirements before grid connection.
consideration before, during, and after installation,
as well as during ongoing use and maintenance.           ⚠   Maintain visibility of warning labels and
The following safety notices are essential for both
                                                         nameplates.
installers and end-users to ensure correct operation
of this product.
                                                         ⚠   Choose battery placement with future user
Improper use could result in harm to the installer,      safety in mind.
the operator, or others, as well as damage to the
battery or connected equipment.
                                                         ⚠   Keep children away from the battery and
WARNINGS:                                                systems.
⚠ Do not make any connections or disconnections
to the system when the batteries are in operation.       ⚠   Use team lifting techniques due to battery
Working with active batteries                            weight.


⚠   Do not charge or discharge battery when              ⚠   Use batteries as directed. Do not open or
ambient temperature is above 55°C (131°F).               modify.


⚠ Keep any flammable/combustible material (e.g.          ⚠   Avoid inserting foreign objects into battery
paper, cloth, plastic, etc.) that may be ignited by      terminals.
heat, sparks, flames, or any other heat source at a
minimum distance of two feet away from the
                                                         ⚠   Handle batteries and/or battery-powered
batteries.
                                                         devices cautiously when using metal tools or when
                                                         around the system. Risk of electrical arcs or short-
⚠ Have a Class ABC or Class BC fire extinguisher         circuits can cause serious harm, death, and
on the premises                                          equipment damage.


⚠ Never short-circuit DC inputs. This may result in      ⚠   Do not charge or discharge the battery if
a risk of electric shock or fire.                        ambient temperature is below -20°C (-4°F).


⚠ Do not disassemble the battery. Contact RISE           ⚠ Beware of the battery current. Ensure that the
Robotics for proper handling instructions. Incorrect     battery is “off” before installing or working on the
servicing or re-assembly may result in a risk of         battery. Use a voltmeter to confirm there is no
electric shock, fire, or voiding of the warranty.        voltage present.




RISE Robotics                                      9 of 33                         www.riserobotics.com
Beltdraulic™ Railgate                                              RISE Robotics



⚠ Always wear protective gear when handling
batteries (PPE).


⚠ Handle batteries carefully to prevent damage.
Avoid pulling, dragging, or mishandling.


⚠      Inspect batteries before use. Don’t use
damaged or swollen batteries. Contact BigBattery
immediately.


⚠ Don’t paint any part of the batteries, inside or
out.


⚠ Make sure all cable connections are properly
tightened and secured, in order to prevent any
accident caused by improper installation.


⚠ Install and remove batteries using the handles
provided.


⚠ Do not place any objects on top of batteries.


⚠ Before storing battery for more than 6 months,
fully charge the battery and disconnect batteries
from your system.




RISE Robotics                                     10 of 33   www.riserobotics.com
Beltdraulic™ Railgate                        RISE Robotics




                        Nomenclature




RISE Robotics               11 of 33   www.riserobotics.com
Beltdraulic™ Railgate                                                            RISE Robotics


                                  Battery Box Nomenclature




Item     Description                              Item     Description

       1 48 Volt Battery                                 8 Negative Terminal

       2 12 to 48 Volt Boost Converter                   9 Battery Box Bracket

       3 12 Volt Input

       4 Antenna

       5 Logic Controller

       6 Positive Terminal

       7 CAN Bus Connections




RISE Robotics                              12 of 33                       www.riserobotics.com
     Beltdraulic™ Railgate                                                                RISE Robotics




     Item     Name   Description     Details           Item   Name       Description   Details

          1   Vent                                         6 Indicator    LED alarm    4 LEDs = 90 - 100%
                                                                         indicator     3 LEDs = 70 - 89%
          2 BAT-     Negative        M8 screw                                          2 LEDs = 25 - 69%
                     battery                                                           1 LEDs = 0 - 24%
                     terminal
                                                           7 CANBus       Input        M6-5P
          3 BAT+     Positive        M8 screw                In          communicati
                     battery                                             on port
                     terminal
                                                           8 CANBus      Output      M6-5P
          4 On/O     Switches                                Out         communicati
            Button   BMS on/o                                            on port
          5   SOC     LED state of
                     charge
                     indicators




     RISE Robotics                              13 of 33                        www.riserobotics.com


      f
ff
Beltdraulic™ Railgate                                                                        RISE Robotics

                                                        ✔ Visually inspect the platform chains and replace

             Operation                                    them if signs of wear or damage are present.

                                                        ✔ Repair any damage to the liftgate to prevent
The following is a list of Do’s and Don’ts for the        accidents.
operation of the liftgate.
                                                        ✔ Close platform when the liftgate is not in use.

Do’s:                                                   ✔ Only lubricate the platform hinge points.

✔ Read and follow warning decals, operating
  decals, and owners manual(s).

✔ Keep all decals in place and legible and retain
  the owners manual(s) in the vehicle or all            Dont’s:
  Warranties are void.
                                                        ✘    Do not overload the platform.
✔ Make sure the vehicle is properly and securely
  braked before using the liftgate.                     ✘    Do not allow children to play around or operate
                                                             the liftgate.
✔ Keep yourself clear of all moving parts.
                                                        ✘    Do not allow unauthorized persons to operate
✔ Make sure the area where the platform will be              your liftgate.
  functioning (up, down, open, and close) is free
  of obstructions and people before operating           ✘    Do not crash your liftgate into loading docks or
  the liftgate.                                              other objects that can inflict severe damage to
                                                             the liftgate.
✔ Make sure the platform area, including the area
  in which loads may fall from the platform, is         ✘    Do not use your liftgate if it shows signs of
  clear before, during, and at all times while               abuse or fails to operate freely and smoothly.
  operating the liftgate.
                                                        ✘    Do not use the liftgate for anything other than
✔ Always place the load as close to the center of            its intended use of loading and unloading
  the platform as possible. Also, position the load          cargo.
  as close to the center of the truck’s rear sill as
  possible.                                             ✘    Do not operate lift trucks on or over any part of
                                                             the platform.
✔ Make sure the slide runners move smoothly
  inside the H-frame columns with no unusual            ✘    Do not stand in the platform’s work area while
  noise or vibration.                                        operating the liftgate or place any object under
                                                             the liftgate work area.
✔ Only operate the liftgate with the Up/Down
  control mounted on the H-frame column or              ✘    Do not drive the truck unless the liftgate is in
  using an optional, inside van control.                     the stored position

✔ Visually inspect your liftgate frequently and
  keep it properly adjusted.




RISE Robotics                                     14 of 33                         www.riserobotics.com
Beltdraulic™ Railgate                                                                      RISE Robotics

                                                        Hold the power button for 1 sec. until the LEDs

Powering Up the Liftgate                                start to light up sequentially (from LED1 - LED5).
                                                        The LEDs will then display the current state of
                                                        charge.
On the ouside of the battery box, there is the user
power switch.




                                                        Once the battery is on, wait 30 seconds and then
                                                        raise the gate until the two arrows are aligned.
                                                        Once the arrows are aligned, press and hold the
                                                        close switch until motion ceases. The liftgate is now
                                                        ready for operation.




Inside the battery box is the battery. To access the
battery box, disengage the three rubber latches
that secure the lid to the battery box, remove the
lid, and place it on the ground.

The power switch, located on top of the battery,
resembles a push button. To turn on the battery,



RISE Robotics                                     15 of 33                       www.riserobotics.com
Beltdraulic™ Railgate                                                                       RISE Robotics


Determining the Battery’s                                Position Platform For Dock
Condition                                                Loading
The battery must be on. The LEDs will display the        1.   Press the “Down” switch to lower the liftgate
state of charge (SOC).                                        platform straight down until the platform is
                                                              below the truck floor.




If the SOC led is flashing, that means the battery is
charging.


Battery Diagnostic light on meaning:
1.   Parallel Wiring Issue
        •      Red On & Orange On
2. Short Circuit
        •      Red On
3. Over Discharge                                        Position Platform For Loading
        •      Red 0.25 seconds 3.75 seconds             And Unloading
4. Over Charge
                                                         1.   Turn ON the main power to the liftgate. The
        •      Red Flashing 3                                 power switch is located on the battery inside
5. Temperature Out of Operating Range                         the battery box. To access the battery box,
        •      Orange On                                      disengage the three rubber latches that secure
                                                              the lid to the battery box, remove the lid, and
6. Under Voltage                                              place it on the ground. The power switch,
        •      Flashing 4                                     located on top of the battery, resembles a push
7.   Failure                                                  button. To turn on the battery, hold the button
                                                              down for 1 second and wait for approximately 2
        •      Orange Flashing 3
                                                              minutes before operating the machine.




RISE Robotics                                      16 of 33                        www.riserobotics.com
Beltdraulic™ Railgate                                                                    RISE Robotics

                                                      1.   Ensure the platform is clear of all objects and
                                                           that everyone is clear of the moving parts of
                                                           the liftgate platform.

                                                      2. Raise the platform until it stops moving.




2. Pull the platform lock latch. Press the “Open”
   switch to unfold the platform. You can release
   the platform lock latch once the platform is in
   motion. Once the platform unfolding sequence
   completes, release the open switch.



                                                      3. Press the “Close” switch to fold the liftgate
                                                         platform. Ensure the platform folds into the
                                                         correct position, which is accompanied by the
                                                         platform lock latch engagment.




3. Press the “Up” or “Down” switch to raise or
   lower the platform.




                                                      4. Turn the liftgate control switch to “Off” by
                                                         holding down the battery button for 4 seconds.
                                                         The battery light indicators should cycle once
                                                         and turn off after 5 seconds.




Position Platform to In-Transit
Stored Position


RISE Robotics                                   17 of 33                        www.riserobotics.com
Beltdraulic™ Railgate                                             RISE Robotics




Cart Stop Operation
1.   To release the cart stop to its open position,
     push the cart stop latch outboard with your
     foot in a hard-soled shoe/boot.

2. To close the cart stop, step on the cart stop
   flipper and press it back down. The cart stop
   will automatically latch into a locked and flat
   position, level with the liftgate platform.




RISE Robotics                                    18 of 33   www.riserobotics.com
Beltdraulic™ Railgate                                                                      RISE Robotics

                                                        personnel who are aware of and understand the

         Maintenance                                    signs of potential problems should maintain the
                                                        liftgate.

Preventive maintenance is one of the most cost eff
ective practices that any equipment owner can
implement. Taking approximately 15 minutes of
your time to inspect the Beltdraulic™ Railgate can
result in hundreds and even thousands of dollars in     Monthly Inspection
savings. These savings can come from:
                                                        Preventive maintenance should be performed on a
•   Increased operating time (no unscheduled            monthly schedule or any time the unit shows signs
    breakdowns at someone’s loading dock).              of improper/abnormal operation or abuse.
                                                        Following these steps helps to ensure maximum
•   Normal wear items will last longer because they     operator safety and your overall performance
    have been properly maintained and lubricated.       satisfaction. This inspection procedure starts at the
                                                        front of the truck and works its way back to the
•   Less chance of someone becoming injured due         liftgate. Ensure the vehicle is securely parked
    to parts that may fail because of mistreatment      before proceeding with the following steps.
    or abuse.
                                                        1.   Check the truck’s battery.
Preventive maintenance inspections should only be
completed with qualified mechanical personnel.               ☐ Check the battery for cracks, leaks, or other
These steps are not intended to encourage the use            apparent damage.
or service of the liftgate by anyone who is not
competent to do so. The overall performance of the           ☐ Make sure the battery hold-down clamp is
liftgate is directly related to the skill and                securely tightened.
knowledge of the mechanic performing the
inspection. If the mechanic cannot identify                  ☐ Make sure the liftgate power cable
potential problems or is unaware of their signs, the         connection is tight.
inspection procedure may be a costly waste of
time.                                                        ☐ Remove any corrosion, dirt, or grease from
                                                             the battery terminals and/or wire connections.

                                                             ☐ Periodically replace the old battery. (Do not
Please do not attempt to maintain the liftgate               let the battery fail and then replace it.)
without fully understanding all of our instructions
and safety precautions. Do not attempt to               2. Check the circuit breakers to ensure the
maintain a liftgate unless you have read and               connections are secure. One circuit breaker is
understand all of the instructions and warnings in         located in the truck’s battery box, and the other
the Installation, Operation, and Maintenance               is in the liftgate’s battery box. Check the power
manual. If any doubt or question arises about the          cut-off switch to ensure it disables power to the
correct or safe method of performing any task              power unit when turned to the off position.
described in this or other Beltdraulic Railgate
manuals, don't hesitate to contact your RISE            3. Check the power cable from the truck battery
Robotics dealer or call the Inside Sales and               back to the liftgate power unit.
Service representatives at our main headquarters.
Proper care is your responsibility. To prevent               ☐ Make sure all connections are free of dirt
serious injury or death, only qualified mechanical           and corrosion.



RISE Robotics                                     19 of 33                        www.riserobotics.com
Beltdraulic™ Railgate                                                                                    RISE Robotics

                                                                           ☐ Check for unusual noises or vibrations as the
      ☐ Make sure all connections are tight.                               liftgate operates.

      ☐ Make sure the entire length of the power                           ☐ Check for any mechanical interference in the
      cable is not cut or damaged.                                         slide runners or as the platform opens.

4. Inspect the power pack enclosure and battery                            ☐ Make sure the liftgate operates freely and
   box for damage.                                                         smoothly throughout its entire range of
                                                                           movement (up, down, open, and closed).
      ☐ Remove any buildup of dirt or debris.
                                                                           ☐ Make sure the platform is level when raised
      ☐ Make sure all the rubber grommets are                              to bed height.
      installed in the access holes through the side
      of the box. This prevents damage to wires and                        ☐ Make sure the platform can be lowered
      hoses from rubbing against the metal                                 straight down (below dock level) for dock
      enclosure's surface.                                                 loading.

5. Inspect the batteries in the battery box                           8. Inspect the liftgate.
   enclosure using the inspection checks in Step 1.
                                                                           ☐     Inspect the liftgate for damage (bent
6. Inspect the wires coming from the battery box                           platform members or slide runners, cracked
   to the liftgate.                                                        welds, etc).

     ☐ Check for signs of chaffing on the outside                          ☐ Check all the fasteners on pins, brackets,
     covering of the wiring.                                               etc., to make sure those parts are securely held
                                                                           in place.
     ☐ Make sure the wires are securely fastened to
     the truck body and not hanging loose where                            ☐ Check the platform chains and connection
     they could be damaged.                                                points. Ensure they are in good condition and
                                                                           the ends are securely connected.
     ☐ Remove any buildup of dirt and debris from
     the hoses and wires.                                                  ☐ Inspect the retention ramp and make sure it
                                                                           works properly.
7.   E n s u re t h e l i f t g a t e o p e ra t e s p ro p e r l y
     throughout its complete opening and closing                           ☐ Oil the platform hinge points.
     cycle. Before operating the liftgate, ensure the
     area is clear of all obstacles, obstructions, and                9. Inspect the slide runners.
     people. Also, if the liftgate is equipped with a
     power cut-off switch, turn the switch to the                          ☐ Clean any build-up of grime or dirt off the
     "On" position.
                                                                           slide runners (power wash if necessary).

     ☐ Check for any clearly visible damage that
                                                                           ☐ Check both mechanical and electrical
     would prevent the liftgate from operating
                                                                           connections to the cylinders.
     properly.
                                                                           ☐ Check for any excessive wear or gouging of
     ☐ Check the control switches for corrosion, dirt
                                                                           slide pads.
     buildup, or damage.
                                                                           ☐   To decrease the effects of road salt, road



RISE Robotics                                                   20 of 33                         www.riserobotics.com
Beltdraulic™ Railgate                                                                                RISE Robotics

   grime, and dirt on the slide runners, you can
   clean the slides and runners with a power
                                                          Semi-Annual Inspection
   washer.
                                                          Belt Inspection
                                                          In addition to the items requiring monthly
   NOTE: There is no need to lubricate the slide
                                                          inspection, the condition of the belt must be
   runners as the materials used are designed to
                                                          assessed every six months. This PILOT model does
   be self-lubricating and require no external
                                                          not feature an integrated belt health monitoring
   lubrication, even in dirty or grimy
                                                          system. Therefore, there is no user-facing method
   environments. These materials incorporate solid
                                                          for directly evaluating belt condition.
   lubricants within the plastic matrix that are
   released during movement, providing a dry and
                                                          Instead, semi-annual belt inspection must be
   maintenance-free operation. This eliminates the
                                                          carried out by qualified RISE Robotics personnel.
   need for messy oils and greases.
                                                          To schedule a belt inspection or for any concerns
                                                          regarding belt longevity, please get in touch with
10. Check cables for both cylinders and in the
                                                          RISE Customer Support or your assigned RISE
    power unit enclosure. Replace the wiring if it
                                                          technician.
    shows signs of excessive abrasion or leakage.
    Tighten any loose terminals and replace any
                                                          Note: Future production models will include an
    connectors which are damaged.
                                                          integrated belt health monitoring system. This will
                                                          be accessible via a mobile application and will
11. Examine all Warning, Capacity, and Operational
                                                          display real-time information on remaining belt life,
    Decals. If they are not readable, they should be
                                                          calculated from usage data. The system will notify
    replaced. New replacement decals can be
                                                          operators when a belt is nearing the end of its
    obtained from RISE Robotics.
                                                          s e r v i ce l i fe, p rov i d i n g c l e a r g u i d a n ce fo r
                                                          replacement scheduling.
12. Place the liftgate in the stored position and turn
    off the power after each use and/or inspection.

13. If you find anything that shows signs of
    excessive wear or damage, replace that part           CRUSH HAZARD
    and any mating parts that may also be                 Do not stand or work in the platform’s work area
    damaged.                                              while operating the liftgate. Place the pressure
                                                          gauge so it can be read while operating the
If you have any doubts or questions about your            liftgate from a safe location. Serious injury or
qualifications to operate or maintain the liftgate,       death could result if this action is not followed.
call us at:

RISE Robotics

1 Union Square,
Somerville, Massachusetts 02143
(909) 744-4135

Web: www.riserobotics.com
Email: liftgate_sales@riserobotics.com
Business Hours: 8:00 AM – 5:00 PM EST, Monday–
Friday




RISE Robotics                                       21 of 33                              www.riserobotics.com
Beltdraulic™ Railgate                                                                   RISE Robotics


Beltdraulic Cylinder Removal
Procedure


These early pilot Beltdraulic Railgate units are
designed for cylinder replacement only in the
field. Field technicians and fleet maintainers are
not authorized to disassemble or service the
Beltdraulic actuator.
All removed cylinders must be returned to RISE        2. Install a ratchet strap to secure the gate in the
Robotics for refurbishment. This procedure may           raised position. This prevents unintended gate
change in future production models.                      descent once the actuator is disconnected.

BEFORE YOU BEGIN                                      3. Turn OFF liftgate power.

Required Equipment                                    4. Disconnect the positive terminal of the 48V
☐ Ratchet strap (rated appropriately)                    battery.
☐ 3/16" hex key
                                                           ⚠ Failure to secure the gate may result in
☐ 9/16" socket or adjustable wrench
☐ 3/4" socket                                              serious injury.
☐ Reverse hammer with threaded pin adapter
☐ Crane, forklift, or lifting mast (20 ft vertical    Step 2 – Remove Rod Pin
reach minimum)
☐ Ladder (as required)

Safety Requirements
☐    Liftgate must be fully closed and in home
position.
☐ Power must be OFF.
☐ 48V battery must be disconnected.
☐ Gate must be mechanically secured to prevent
movement.
☐ Proper PPE required.

REMOVAL PROCEDURE                                     1.   Remove Rod Pin Cover.

Step 1 – Secure and Power Down                        2. Locate the rod pin connecting the actuator rod
1. Fully close the liftgate.                             to the liftgate runner.
   The gate must be:
   • Fully folded                                     3. Using a 3/16" hex key, remove the pin retainer
   • In its highest (home) position                      fastener.

                                                      4. Thread the reverse hammer adapter onto the
                                                         rod pin.




RISE Robotics                                   22 of 33                       www.riserobotics.com
Beltdraulic™ Railgate                                                                         RISE Robotics

5. Carefully extract the pin using controlled            Ensure connectors are free and will not snag during
   reverse hammering.                                    lifting.

Once removed, the actuator rod is free from the          Step 5 – Remove Actuator Assembly
runner.

Step 3 – Remove Column Lid Fasteners




1.   Using a 9/16" socket (or adjustable wrench),
     remove the inward-facing bolts at the top of the
     column.
                                                         1.   Attach lifting equipment to the eyebolt located
2. A tall ladder may be required to access these              on the column lid plate.
   fasteners safely.
                                                         2. Slowly lift the actuator vertically.

Step 4 – Disconnect Electrical Connectors                3. Continue lifting until the actuator rod fully
                                                            clears the top of the column.
1.   Locate the electrical connectors at the actuator
     box base (downward facing).                         4. Once clear, carefully lower the actuator to
                                                            ground level.
2. Disconnect all connectors between the column
   and actuator.                                         An assistant positioned on a ladder may be
                                                         required to guide the assembly safely past
     ⚠ IMPORTANT:                                        obstructions.
     Failure to disconnect electrical connectors
     before lifting will cause connector and
     actuator damage.




RISE Robotics                                      23 of 33                         www.riserobotics.com
Beltdraulic™ Railgate                                                                           RISE Robotics

Step 6 – Separate Column Lid Plate                        Web: www.riserobotics.com
                                                          Email: liftgate_sales@riserobotics.com
                                                          Business Hours: 8:00 AM – 5:00 PM EST, Monday–
                                                          Friday


                                                          Beltdraulic Cylinder
                                                          Installation Procedure
                                                          Step 1 – Install Correct Column Lid Plate

                                                          1.  Identify correct side:
                                                            • Curb Side
                                                            • Street Side
                                                          2. Verify tab orientation:

                                                               • Tabs must face inward toward liftgate center.

                                                               • Curb side tabs face left (toward street side
                                                                 column).

                                                               • Street side tabs face right (toward curb side
                                                                 column).

                                                               • Larger actuator box protrusion faces toward the
                                                                 front of the truck.
1.   Place the actuator assembly on a workbench.
                                                          3. Install spherical cup fastener using 3/4" socket.
2. Using a 3/4" socket, remove the spherical cup
   fastener securing the column lid plate.                Ensure assembly is secure before lifting.

3. Remove and retain the column lid plate.                Step 2 – Lift and Insert Actuator

The Beltdraulic actuator is now ready for return.         1.    Attach lifting device to eyebolt.

                                                          2. Hoist actuator vertically along column.
Step 7 – Return Actuator
                                                          3. Continue until actuator rod clears column
Do not disassemble the actuator.                             opening.

Contact your RISE Robotics Service Representative         4. Carefully guide and lower actuator into column.
to arrange return shipment for refurbishment.
                                                          If column lid plate does not seat properly:
RISE Robotics
1 Union Square,                                           • Rod may not be aligned with runner.
Somerville, Massachusetts 02143
(909) 744-4135                                            • Look through column access openings.




RISE Robotics                                       24 of 33                           www.riserobotics.com
Beltdraulic™ Railgate                                                  RISE Robotics

• Gently guide rod into correct position.

• Once aligned, lower fully until lid plate seats flush.

Step 3 – Install Rod Pin

1.   Align rod end with runner.

2. Orient rod pin so safety hole aligns properly.

3. Tap pin into place until flush.

4. Reinstall pin retainer using 3/16" hex key.


Step 4 – Reconnect Electrical Connectors

Reconnect all actuator electrical connections
securely.

Verify connectors are fully seated and properly
oriented.

Step 5 – Restore Power

1.   Remove lifting device.

2. Remove gate ratchet strap.

3. Reconnect 48V battery.

4. Turn liftgate power ON.

5. Test gate operation.

Liftgate is now ready for service.




RISE Robotics                                         25 of 33   www.riserobotics.com
Beltdraulic™ Railgate                                                                       RISE Robotics


              Warranty                                  Limited Warranty
                                                        Beltdraulic Railgate
Inspect Cylinder Piston Seals
                                                        Pre-Production Units
Inspect the cylinder piston rod seals for scoring by
                                                        3 yrs Mechanical + 3 yrs Electric
lower the platform all the way and inspect the
polished rod of the cylinder for any signs of
                                                        Thank you for choosing RISE Robotics as your
marinating, corrosion, or kinks that would
                                                        partner in innovation. As a valued participant in our
potentially affect effective operation.
                                                        pilot program, your Beltdraulic Railgate is part of a
                                                        pre-production initiative designed to optimize
                                                        performance in real-world applications. This unit is
Platform Movement Timing
                                                        a pre-production model intended for early
Under normal operation, the platform should:
                                                        adopters. We are fully committed to addressing
                                                        any design issues that may arise during your
•   Open or close fully within 5 to 10 seconds
                                                        evaluation of the unit.
•   Raise or lower within 10 to 15 seconds, whether
    loaded or unloaded
                                                        SUPPORT COMMITMENT
                                                        A 3-year limited support coverage backs your
These ranges represent expected performance for
                                                        Beltdraulic Railgate for all mechanical and electrical
this PILOT model. Significant deviations from these
                                                        components. While this is not a traditional warranty
timings may indicate obstructions or maintenance
                                                        in the commercial sense, RISE Robotics will provide
needs.
                                                        direct support, including onsite service from our
                                                        technical team, to promptly resolve any issues
If the platform is moving noticeably slower than
                                                        encountered during the pilot period. This support
expected:
                                                        includes: Your Beltdraulic Railgate is backed by a 3-
• Perform a basic walkaround inspection of the
                                                        year limited warranty support coverage for all
    machine
                                                        mechanical, electrical, and hydraulic components.
                                                        While this is not a traditional warranty in the
•   Look for any foreign objects, debris, or
                                                        commercial sense, RISE Robotics will provide direct
    structural interference that may be lodged in
                                                        support, including onsite service from our technical
    the moving components
                                                        team, to promptly resolve any issues encountered
                                                        during the pilot period. This support includes:
•   If safe to do so, carefully remove any visible
                                                        • Full coverage of any component failures
    obstructions
                                                            resulting from normal use
                                                        • Dispatch of RISE technicians or authorized
If the cause of abnormal timing cannot be visually
                                                            partners for field service
identified or the platform appears to be moving
                                                        • No-cost replacement of failed parts (including
too quickly, do not operate further. Instead, please
                                                            shipping)
get in touch with RISE Robotics for support to
                                                        • Close collaboration to ensure product feedback
investigate and ensure the system is operating
                                                            is addressed swiftly
safely and correctly.
                                                        This coverage is available only to original pilot
                                                        participants, commencing from the date of
Note: Production versions of this system will
                                                        shipment from our facility.
include integrated diagnostic tools to help identify
timing anomalies and their causes. These tools will
                                                        PILOT SERVICE TERMS
be accessible via the mobile application.
                                                        Unlike a commercial warranty requiring claims
                                                        submission and authorization processes, all pilot
                                                        support requests should be directed to the RISE



RISE Robotics                                     26 of 33                        www.riserobotics.com
Beltdraulic™ Railgate                                              RISE Robotics

Customer Success Team. There is no need to file
formal claims or return parts unless requested by
our engineers for evaluation.
Should your liftgate require service, please contact
us directly:

RISE Robotics
1 Union Square, Somerville, MA 02143
📞 (909) 744-4135

🌐 www.riserobotics.com

📧 liftgate_sales@riserobotics.com

🕗 Monday–Friday, 8:00 AM – 5:00 PM EST


WHAT’S NOT COVERED
This pilot coverage excludes:
• Damage due to misuse, abuse, or unauthorized
  modifications
• Incidental or consequential damages such as
  vehicle downtime, lost revenue, or operational
  delays
• Cosmetic wear and tear or finish degradation
  over time

As this product is still in development, your
participation is crucial in helping us refine and
improve the Beltdraulic Railgate. We deeply value
your insights and are committed to making this
pilot a success for you.




RISE Robotics                                     27 of 33   www.riserobotics.com
Beltdraulic™ Railgate                                                                                 RISE Robotics


     Troubleshooting

                                                 Troubleshooting Chart

            Problem                         Possible Causes                           Possible Solution

The motor does not run when          The battery is not on.            Turn on the battery in the battery box.
the control switch is activated.
                                     Dead or low battery.              Make sure battery is fully charged. Check for
                                                                       loose or corroded battery connections.
                                                                       Replace or recharge battery.

                                     Corroded or loose wire            Check all wire connections on power unit
                                     connections.                      for corrosion or looseness. Replace
                                                                       defective terminals with “heat shrink”
                                                                       factory type terminals. Check main power
                                                                       cable from batteries, to circuit breakers, to
                                                                       cut-off switch, to power unit.

                                     Blown circuit breaker(s).         Reset or replace circuit breaker(s).

                                     Blown 10 Amp fuse in power        Replace, if fuse is blown. If problem
                                     unit box.                         continues, check for shorts in the electrical
                                                                       system.

                                     Defective Control box             Check switch. Replace if defective.
                                     switch.

                                     Defective motor(s).               If the motor is determined to be defective, it
                                                                       should be replaced. Uncontrolled
                                                                       overheating, loose connections, and
                                                                       corrosion are typically causes of faulty
                                                                       motors.

                                     If a liftgate is installed on a semi-trailer, ensure the battery wire is at least
                                     two-gauge or heavier. Smaller wires can reduce the voltage, potentially
                                     leading to battery box faults or failures.

                                     If the liftgate does not operate in freezing conditions, ensure the battery
                                     box is dry and does not contain water.

The liftgate will not lower to the   Structural damage.                Fix damage. Replace worn parts. Check
ground.                                                                clearance between platform and dock
                                                                       bumpers.

                                     Defective control switch.         Check switch. Replace if defective.

                                     Low Voltage                       Recharge battery (if less than 9 volts).

                                     Defective actuator motor          Replace Cylinder.




RISE Robotics                                           28 of 33                            www.riserobotics.com
Beltdraulic™ Railgate                                                             RISE Robotics




                               Troubleshooting Chart

         Problem                       Possible Causes                  Possible Solution

 The platform will not              Load capacity has         Verify load capacity and adjust
 raise, will not raise rated        been exceeded.            load weight.
 capacity, or raise, but
 drift down when the                Structural damage.        Replace damaged parts.
 control switch is
                                    Low Voltage.              Inspect the battery connection
 released.
                                                              terminals and check the battery’s
                                                              Voltage (9 Volts minimum).

 Liftgate will not open.            Platform operating area   Clear platform operating area.
                                    is not clear.

                                    Blown circuit breaker     Check all connectors and
                                                              connections for worn or loose parts,
                                                              replace any worn terminals with “heat
                                                              shrink” factory terminals. Reset
                                                              circuit breaker.

                                    Blown in-line fuse.       Replace blown fuse with 10 Amp ATO
                                                              or ATC fuse.

 Platform lowers                    Slide runners or wear     Clean columns and slide runners with
 extremely slow.                    strips are dirty,         high-pressure washer. Replace slide
                                    damaged, or need oil.     runners or wear strips if they are bent
                                                              or damaged.

                                    Cylinder rod is scored,   Replace cylinder.
                                    pitted, or bent.

 Platform will not close            Twisted platform hinge    Check to see if twisted by lowering
 completely.                        pin (hex pin).            platform below column to see hex
                                                              pin. Check alignment of hex pin and
                                                              lower cylinder pin, should be in
                                                              between the 8 o’clock and 9 o’clock
                                                              position with platform open. If not,
                                                              replace by sawing pin in half and
                                                              removing pin and bushings. Replace
                                                              hex pin and both hex bushings

                                    Closure cylinder          Replace cylinder. DO NOT repack or
                                    defective.                dismantle.

 Platform will not close            Low Voltage               Recharge battery (if less than 9
 at all, motor does run.                                      volts).

                                    Motor overheat            Wait for about 5 minutes for heat to
                                                              naturally dissipate.




RISE Robotics                        29 of 33                           www.riserobotics.com
Beltdraulic™ Railgate                                                          RISE Robotics


  Inspection Record

                                    RISE Robotics
                        Beltdraulic Liftgate Inspection Record

 Date of Inspection         Notes, observations, maintenance performed, etc.




RISE Robotics                         30 of 33                       www.riserobotics.com
Beltdraulic™ Railgate                                                          RISE Robotics



                                    RISE Robotics
                        Beltdraulic Liftgate Inspection Record

Date of Inspection          Notes, observations, maintenance performed, etc.




RISE Robotics                         31 of 33                        www.riserobotics.com
Beltdraulic™ Railgate                    RISE Robotics


                Notes




RISE Robotics           32 of 33   www.riserobotics.com
Beltdraulic™ Railgate                                                                  RISE Robotics




                    If you have any questions during installation, operation, or
                 maintenance of this liftgate, contact RISE Robotics for assistance.

                                           RISE Robotics

                                         1 Union Square,
                                 Somerville, Massachusetts 02143
                                         (909) 744-4135

                                  Web: www.riserobotics.com
                             Email: liftgate_sales@riserobotics.com
                     Business Hours: 8:00 AM – 5:00 PM EST, Monday–Friday




RISE Robotics                                33 of 33                          www.riserobotics.com


[READING ORDER TEXT]
Beltdraulic™ Railgate RISE Robotics
RISE Robotics of 1 33 www.riserobotics.com
Beltdraulic™ Railgate 5500
MADE IN THE USA
OPERATORS MANUAL
For 4500, 5500, and 6500 Beltdraulic Railgate Pre-Production ModelsBeltdraulic™ Railgate RISE Robotics
RISE Robotics of 2 33 www.riserobotics.com
QUICK START GUIDEBeltdraulic™ Railgate RISE Robotics
RISE Robotics of 3 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
TABLE OF
CONTENTS
Safety....................................................................................................5
Nomenclature ...................................................................................11
Operation ..........................................................................................14
Maintenance.....................................................................................19
Warranty...........................................................................................26
Troubleshooting.............................................................................28
Inspection Record.........................................................................30
Notes..................................................................................................32
RISE Robotics of 4 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Safety
A restraining system may be necessary to secure
certain types of cargo on the liftgate platform,
depending on the specific application, such as a
cart stop, retention ramp, fencing, or straps. This
should be considered by the purchaser for their
particular application to prevent the possibility of
severe personal injury or death due to cargo
shifting and/or falling from the liftgate platform. All
operators must be fully trained and have read the
full operator's manual before operating the liftgate.
It is imperative to articulate the following, despite
its apparent obviousness:
Only qualified personnel familiar with welding and
material handling equipment, such as forklifts,
should be authorized to install this liftgate.
If installers have any questions, they may contact
RISE Robotics at the contact information provided
on the last page of this document.
It is the responsibility of the installer/operator to
understand and perform proper operating
procedures. Be aware of the inherent dangers in
the use of this product and the tools used to install
it. Read and understand all Danger, Warnings,
Cautions, and Important Notices in this manual and
on the liftgate or truck.
This is the safety alert symbol. It is
used to alert you to potential
personal injury hazards. Obey all
safety messages that follow this
symbol to avoid possible injury or
death.
This manual contains DANGERS, SAFETY
INSTRUCTIONS, CAUTIONS, IMPORTANT
NOTICES, and NOTES which must be followed to
prevent the possibility of improper service, damage
to the equipment, personal injury, or death. The
following keywords call the readers’ attention to
potential hazards.
Hazards are identified by the “Safety Alert Symbol”
such as “DANGER”, “WARNING”, or “CAUTION”.
Note: This contains additional information
necessary to a procedure.
Most accidents involving the operation,
maintenance, or repair of products made by RISE
RISE Robotics of 5 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Robotics occur because the owner/installer/
operator fails to observe safety precautions or
operating instructions. Accidents can often be
avoided by being alert and recognizing potentially
hazardous situations. Any individuals installing,
operating, repairing, or maintaining liftgates should
have the necessary training, skills, and tools to
perform these functions correctly and safely. The
safety information in this manual serves as a basic
guide to prevent injury or death.
The warnings in this manual and on the product
itself are not all-inclusive.
DO NOT proceed if any doubt arises about the
correct or safe method of performing anything
found in this or other RISE Robotics manuals. Seek
out expert assistance from a qualified person
before continuing.
Do not attempt to install, operate, or maintain our
product without fully understanding all precautions
and safety recommendations. Do not operate or
work on a truck or lift gate unless you have read
and understand the instructions and warnings in
the Installation Manual.
RISE Robotics of 6 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Safety Icons
RISE Robotics of 7 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
RISE Robotics of 8 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Battery Safety
Note: Read and follow all safety instructions for
handling the battery before servicing, installation,
or troubleshooting.
Lithium Iron Phosphate (LiFePO4) batteries are an
inherently safe chemistry. However, safety
measures should always be taken into
consideration before, during, and after installation,
as well as during ongoing use and maintenance.
The following safety notices are essential for both
installers and end-users to ensure correct operation
of this product.
Improper use could result in harm to the installer,
the operator, or others, as well as damage to the
battery or connected equipment.
WARNINGS:
⚠ Do not make any connections or disconnections
to the system when the batteries are in operation.
Working with active batteries
⚠ Do not charge or discharge battery when
ambient temperature is above 55°C (131°F).
⚠ Keep any flammable/combustible material (e.g.
paper, cloth, plastic, etc.) that may be ignited by
heat, sparks, flames, or any other heat source at a
minimum distance of two feet away from the
batteries.
⚠ Have a Class ABC or Class BC fire extinguisher
on the premises
⚠ Never short-circuit DC inputs. This may result in
a risk of electric shock or fire.
⚠ Do not disassemble the battery. Contact RISE
Robotics for proper handling instructions. Incorrect
servicing or re-assembly may result in a risk of
electric shock, fire, or voiding of the warranty.
PRECAUTIONS:
⚠ Qualified personnel must handle all product
work to reduce risk of electric shock.
⚠ Follow local and national electrical standards for
installation and confirm utility provider and local
authority requirements before grid connection.
⚠ Maintain visibility of warning labels and
nameplates.
⚠ Choose battery placement with future user
safety in mind.
⚠ Keep children away from the battery and
systems.
⚠ Use team lifting techniques due to battery
weight.
⚠ Use batteries as directed. Do not open or
modify.
⚠ Avoid inserting foreign objects into battery
terminals.
⚠ Handle batteries and/or battery-powered
devices cautiously when using metal tools or when
around the system. Risk of electrical arcs or short-
circuits can cause serious harm, death, and
equipment damage.
⚠ Do not charge or discharge the battery if
ambient temperature is below -20°C (-4°F).
⚠ Beware of the battery current. Ensure that the
battery is “off” before installing or working on the
battery. Use a voltmeter to confirm there is no
voltage present.
RISE Robotics of 9 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
⚠ Always wear protective gear when handling
batteries (PPE).
⚠ Handle batteries carefully to prevent damage.
Avoid pulling, dragging, or mishandling.
⚠ Inspect batteries before use. Don’t use
damaged or swollen batteries. Contact BigBattery
immediately.
⚠ Don’t paint any part of the batteries, inside or
out.
⚠ Make sure all cable connections are properly
tightened and secured, in order to prevent any
accident caused by improper installation.
⚠ Install and remove batteries using the handles
provided.
⚠ Do not place any objects on top of batteries.
⚠ Before storing battery for more than 6 months,
fully charge the battery and disconnect batteries
from your system.
RISE Robotics of 10 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Nomenclature
RISE Robotics of 11 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Battery Box Nomenclature
Item Description
1 48 Volt Battery
2 12 to 48 Volt Boost Converter
3 12 Volt Input
4 Antenna
5 Logic Controller
6 Positive Terminal
7 CAN Bus Connections
Item Description
8 Negative Terminal
9 Battery Box Bracket
RISE Robotics of 12 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Item Name Description Details
1 Vent
2 BAT- Negative
battery
terminal
M8 screw
3 BAT+ Positive
battery
terminal
M8 screw
4 On/O
ff
Button
Switches
BMS on/o
f
5 SOC LED state of
charge
indicators
6 Indicator LED alarm
indicator
4 LEDs = 90 - 100%
3 LEDs = 70 - 89%
2 LEDs = 25 - 69%
1 LEDs = 0 - 24%
7 CANBus
In
Input
communicati
on port
M6-5P
8 CANBus
Out
Output
communicati
on port
M6-5P
Item Name Description Details
RISE Robotics of 13 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Operation
The following is a list of Do’s and Don’ts for the
operation of the liftgate.
Do’s:
✔ Read and follow warning decals, operating
decals, and owners manual(s).
✔ Keep all decals in place and legible and retain
the owners manual(s) in the vehicle or all
Warranties are void.
✔ Make sure the vehicle is properly and securely
braked before using the liftgate.
✔ Keep yourself clear of all moving parts.
✔ Make sure the area where the platform will be
functioning (up, down, open, and close) is free
of obstructions and people before operating
the liftgate.
✔ Make sure the platform area, including the area
in which loads may fall from the platform, is
clear before, during, and at all times while
operating the liftgate.
✔ Always place the load as close to the center of
the platform as possible. Also, position the load
as close to the center of the truck’s rear sill as
possible.
✔ Make sure the slide runners move smoothly
inside the H-frame columns with no unusual
noise or vibration.
✔ Only operate the liftgate with the Up/Down
control mounted on the H-frame column or
using an optional, inside van control.
✔ Visually inspect your liftgate frequently and
keep it properly adjusted.
✔ Visually inspect the platform chains and replace
them if signs of wear or damage are present.
✔ Repair any damage to the liftgate to prevent
accidents.
✔ Close platform when the liftgate is not in use.
✔ Only lubricate the platform hinge points.
Dont’s:
✘ Do not overload the platform.
✘ Do not allow children to play around or operate
the liftgate.
✘ Do not allow unauthorized persons to operate
your liftgate.
✘ Do not crash your liftgate into loading docks or
other objects that can inflict severe damage to
the liftgate.
✘ Do not use your liftgate if it shows signs of
abuse or fails to operate freely and smoothly.
✘ Do not use the liftgate for anything other than
its intended use of loading and unloading
cargo.
✘ Do not operate lift trucks on or over any part of
the platform.
✘ Do not stand in the platform’s work area while
operating the liftgate or place any object under
the liftgate work area.
✘ Do not drive the truck unless the liftgate is in
the stored position
RISE Robotics of 14 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Powering Up the Liftgate
On the ouside of the battery box, there is the user
power switch.
Inside the battery box is the battery. To access the
battery box, disengage the three rubber latches
that secure the lid to the battery box, remove the
lid, and place it on the ground.
The power switch, located on top of the battery,
resembles a push button. To turn on the battery,
Hold the power button for 1 sec. until the LEDs
start to light up sequentially (from LED1 - LED5).
The LEDs will then display the current state of
charge.
Once the battery is on, wait 30 seconds and then
raise the gate until the two arrows are aligned.
Once the arrows are aligned, press and hold the
close switch until motion ceases. The liftgate is now
ready for operation.
RISE Robotics of 15 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Determining the Battery’s
Condition
The battery must be on. The LEDs will display the
state of charge (SOC).
If the SOC led is flashing, that means the battery is
charging.
Battery Diagnostic light on meaning:
1. Parallel Wiring Issue
• Red On & Orange On
2. Short Circuit
• Red On
3. Over Discharge
• Red 0.25 seconds 3.75 seconds
4. Over Charge
• Red Flashing 3
5. Temperature Out of Operating Range
• Orange On
6. Under Voltage
• Flashing 4
7. Failure
• Orange Flashing 3
Position Platform For Dock
Loading
1. Press the “Down” switch to lower the liftgate
platform straight down until the platform is
below the truck floor.
Position Platform For Loading
And Unloading
1. Turn ON the main power to the liftgate. The
power switch is located on the battery inside
the battery box. To access the battery box,
disengage the three rubber latches that secure
the lid to the battery box, remove the lid, and
place it on the ground. The power switch,
located on top of the battery, resembles a push
button. To turn on the battery, hold the button
down for 1 second and wait for approximately 2
minutes before operating the machine.
RISE Robotics of 16 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
2. Pull the platform lock latch. Press the “Open”
switch to unfold the platform. You can release
the platform lock latch once the platform is in
motion. Once the platform unfolding sequence
completes, release the open switch.
3. Press the “Up” or “Down” switch to raise or
lower the platform.
Position Platform to In-Transit
Stored Position
1. Ensure the platform is clear of all objects and
that everyone is clear of the moving parts of
the liftgate platform.
2. Raise the platform until it stops moving.
3. Press the “Close” switch to fold the liftgate
platform. Ensure the platform folds into the
correct position, which is accompanied by the
platform lock latch engagment.
4. Turn the liftgate control switch to “Off” by
holding down the battery button for 4 seconds.
The battery light indicators should cycle once
and turn off after 5 seconds.
RISE Robotics of 17 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Cart Stop Operation
1. To release the cart stop to its open position,
push the cart stop latch outboard with your
foot in a hard-soled shoe/boot.
2. To close the cart stop, step on the cart stop
flipper and press it back down. The cart stop
will automatically latch into a locked and flat
position, level with the liftgate platform.
RISE Robotics of 18 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Maintenance
Preventive maintenance is one of the most cost eff
ective practices that any equipment owner can
implement. Taking approximately 15 minutes of
your time to inspect the Beltdraulic™ Railgate can
result in hundreds and even thousands of dollars in
savings. These savings can come from:
• Increased operating time (no unscheduled
breakdowns at someone’s loading dock).
• Normal wear items will last longer because they
have been properly maintained and lubricated.
• Less chance of someone becoming injured due
to parts that may fail because of mistreatment
or abuse.
Preventive maintenance inspections should only be
completed with qualified mechanical personnel.
These steps are not intended to encourage the use
or service of the liftgate by anyone who is not
competent to do so. The overall performance of the
liftgate is directly related to the skill and
knowledge of the mechanic performing the
inspection. If the mechanic cannot identify
potential problems or is unaware of their signs, the
inspection procedure may be a costly waste of
time.
Please do not attempt to maintain the liftgate
without fully understanding all of our instructions
and safety precautions. Do not attempt to
maintain a liftgate unless you have read and
understand all of the instructions and warnings in
the Installation, Operation, and Maintenance
manual. If any doubt or question arises about the
correct or safe method of performing any task
described in this or other Beltdraulic Railgate
manuals, don't hesitate to contact your RISE
Robotics dealer or call the Inside Sales and
Service representatives at our main headquarters.
Proper care is your responsibility. To prevent
serious injury or death, only qualified mechanical
personnel who are aware of and understand the
signs of potential problems should maintain the
liftgate.
Monthly Inspection
Preventive maintenance should be performed on a
monthly schedule or any time the unit shows signs
of improper/abnormal operation or abuse.
Following these steps helps to ensure maximum
operator safety and your overall performance
satisfaction. This inspection procedure starts at the
front of the truck and works its way back to the
liftgate. Ensure the vehicle is securely parked
before proceeding with the following steps.
1. Check the truck’s battery.
☐ Check the battery for cracks, leaks, or other
apparent damage.
☐ Make sure the battery hold-down clamp is
securely tightened.
☐ Make sure the liftgate power cable
connection is tight.
☐ Remove any corrosion, dirt, or grease from
the battery terminals and/or wire connections.
☐ Periodically replace the old battery. (Do not
let the battery fail and then replace it.)
2. Check the circuit breakers to ensure the
connections are secure. One circuit breaker is
located in the truck’s battery box, and the other
is in the liftgate’s battery box. Check the power
cut-off switch to ensure it disables power to the
power unit when turned to the off position.
3. Check the power cable from the truck battery
back to the liftgate power unit.
☐ Make sure all connections are free of dirt
and corrosion.
RISE Robotics of 19 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
☐ Make sure all connections are tight.
☐ Make sure the entire length of the power
cable is not cut or damaged.
4. Inspect the power pack enclosure and battery
box for damage.
☐ Remove any buildup of dirt or debris.
☐ Make sure all the rubber grommets are
installed in the access holes through the side
of the box. This prevents damage to wires and
hoses from rubbing against the metal
enclosure's surface.
5. Inspect the batteries in the battery box
enclosure using the inspection checks in Step 1.
6. Inspect the wires coming from the battery box
to the liftgate.
☐ Check for signs of chaffing on the outside
covering of the wiring.
☐ Make sure the wires are securely fastened to
the truck body and not hanging loose where
they could be damaged.
☐ Remove any buildup of dirt and debris from
the hoses and wires.
7. Ensure the liftgate operates properly
throughout its complete opening and closing
cycle. Before operating the liftgate, ensure the
area is clear of all obstacles, obstructions, and
people. Also, if the liftgate is equipped with a
power cut-off switch, turn the switch to the
"On" position.
☐ Check for any clearly visible damage that
would prevent the liftgate from operating
properly.
☐ Check the control switches for corrosion, dirt
buildup, or damage.
☐ Check for unusual noises or vibrations as the
liftgate operates.
☐ Check for any mechanical interference in the
slide runners or as the platform opens.
☐ Make sure the liftgate operates freely and
smoothly throughout its entire range of
movement (up, down, open, and closed).
☐ Make sure the platform is level when raised
to bed height.
☐ Make sure the platform can be lowered
straight down (below dock level) for dock
loading.
8. Inspect the liftgate.
☐ Inspect the liftgate for damage (bent
platform members or slide runners, cracked
welds, etc).
☐ Check all the fasteners on pins, brackets,
etc., to make sure those parts are securely held
in place.
☐ Check the platform chains and connection
points. Ensure they are in good condition and
the ends are securely connected.
☐ Inspect the retention ramp and make sure it
works properly.
☐ Oil the platform hinge points.
9. Inspect the slide runners.
☐ Clean any build-up of grime or dirt off the
slide runners (power wash if necessary).
☐ Check both mechanical and electrical
connections to the cylinders.
☐ Check for any excessive wear or gouging of
slide pads.
☐ To decrease the effects of road salt, road
RISE Robotics of 20 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
grime, and dirt on the slide runners, you can
clean the slides and runners with a power
washer.
NOTE: There is no need to lubricate the slide
runners as the materials used are designed to
be self-lubricating and require no external
lubrication, even in dirty or grimy
environments. These materials incorporate solid
lubricants within the plastic matrix that are
released during movement, providing a dry and
maintenance-free operation. This eliminates the
need for messy oils and greases.
10. Check cables for both cylinders and in the
power unit enclosure. Replace the wiring if it
shows signs of excessive abrasion or leakage.
Tighten any loose terminals and replace any
connectors which are damaged.
11. Examine all Warning, Capacity, and Operational
Decals. If they are not readable, they should be
replaced. New replacement decals can be
obtained from RISE Robotics.
12. Place the liftgate in the stored position and turn
off the power after each use and/or inspection.
13. If you find anything that shows signs of
excessive wear or damage, replace that part
and any mating parts that may also be
damaged.
If you have any doubts or questions about your
qualifications to operate or maintain the liftgate,
call us at:
RISE Robotics
1 Union Square,
Somerville, Massachusetts 02143
(909) 744-4135
Web: www.riserobotics.com
Email: liftgate_sales@riserobotics.com
Business Hours: 8:00 AM – 5:00 PM EST, Monday–
Friday
Semi-Annual Inspection
Belt Inspection
In addition to the items requiring monthly
inspection, the condition of the belt must be
assessed every six months. This PILOT model does
not feature an integrated belt health monitoring
system. Therefore, there is no user-facing method
for directly evaluating belt condition.
Instead, semi-annual belt inspection must be
carried out by qualified RISE Robotics personnel.
To schedule a belt inspection or for any concerns
regarding belt longevity, please get in touch with
RISE Customer Support or your assigned RISE
technician.
Note: Future production models will include an
integrated belt health monitoring system. This will
be accessible via a mobile application and will
display real-time information on remaining belt life,
calculated from usage data. The system will notify
operators when a belt is nearing the end of its
service life, providing clear guidance for
replacement scheduling.
CRUSH HAZARD
Do not stand or work in the platform’s work area
while operating the liftgate. Place the pressure
gauge so it can be read while operating the
liftgate from a safe location. Serious injury or
death could result if this action is not followed.
RISE Robotics of 21 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Beltdraulic Cylinder Removal
Procedure
These early pilot Beltdraulic Railgate units are
designed for cylinder replacement only in the
field. Field technicians and fleet maintainers are
not authorized to disassemble or service the
Beltdraulic actuator.
All removed cylinders must be returned to RISE
Robotics for refurbishment. This procedure may
change in future production models.
BEFORE YOU BEGIN
Required Equipment
☐ Ratchet strap (rated appropriately)
☐ 3/16" hex key
☐ 9/16" socket or adjustable wrench
☐ 3/4" socket
☐ Reverse hammer with threaded pin adapter
☐ Crane, forklift, or lifting mast (20 ft vertical
reach minimum)
☐ Ladder (as required)
Safety Requirements
☐ Liftgate must be fully closed and in home
position.
☐ Power must be OFF.
☐ 48V battery must be disconnected.
☐ Gate must be mechanically secured to prevent
movement.
☐ Proper PPE required.
REMOVAL PROCEDURE
Step 1 – Secure and Power Down
1. Fully close the liftgate.
The gate must be:
• Fully folded
• In its highest (home) position
2. Install a ratchet strap to secure the gate in the
raised position. This prevents unintended gate
descent once the actuator is disconnected.
3. Turn OFF liftgate power.
4. Disconnect the positive terminal of the 48V
battery.
⚠ Failure to secure the gate may result in
serious injury.
Step 2 – Remove Rod Pin
1. Remove Rod Pin Cover.
2. Locate the rod pin connecting the actuator rod
to the liftgate runner.
3. Using a 3/16" hex key, remove the pin retainer
fastener.
4. Thread the reverse hammer adapter onto the
rod pin.
RISE Robotics of 22 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
5. Carefully extract the pin using controlled
reverse hammering.
Once removed, the actuator rod is free from the
runner.
Step 3 – Remove Column Lid Fasteners
1. Using a 9/16" socket (or adjustable wrench),
remove the inward-facing bolts at the top of the
column.
2. A tall ladder may be required to access these
fasteners safely.
Step 4 – Disconnect Electrical Connectors
1. Locate the electrical connectors at the actuator
box base (downward facing).
2. Disconnect all connectors between the column
and actuator.
⚠ IMPORTANT:
Failure to disconnect electrical connectors
before lifting will cause connector and
actuator damage.
Ensure connectors are free and will not snag during
lifting.
Step 5 – Remove Actuator Assembly
1. Attach lifting equipment to the eyebolt located
on the column lid plate.
2. Slowly lift the actuator vertically.
3. Continue lifting until the actuator rod fully
clears the top of the column.
4. Once clear, carefully lower the actuator to
ground level.
An assistant positioned on a ladder may be
required to guide the assembly safely past
obstructions.
RISE Robotics of 23 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Step 6 – Separate Column Lid Plate
1. Place the actuator assembly on a workbench.
2. Using a 3/4" socket, remove the spherical cup
fastener securing the column lid plate.
3. Remove and retain the column lid plate.
The Beltdraulic actuator is now ready for return.
Step 7 – Return Actuator
Do not disassemble the actuator.
Contact your RISE Robotics Service Representative
to arrange return shipment for refurbishment.
RISE Robotics
1 Union Square,
Somerville, Massachusetts 02143
(909) 744-4135
Web: www.riserobotics.com
Email: liftgate_sales@riserobotics.com
Business Hours: 8:00 AM – 5:00 PM EST, Monday–
Friday
Beltdraulic Cylinder
Installation Procedure
Step 1 – Install Correct Column Lid Plate
1. Identify correct side:
• Curb Side
• Street Side
2. Verify tab orientation:
• Tabs must face inward toward liftgate center.
• Curb side tabs face left (toward street side
column).
• Street side tabs face right (toward curb side
column).
• Larger actuator box protrusion faces toward the
front of the truck.
3. Install spherical cup fastener using 3/4" socket.
Ensure assembly is secure before lifting.
Step 2 – Lift and Insert Actuator
1. Attach lifting device to eyebolt.
2. Hoist actuator vertically along column.
3. Continue until actuator rod clears column
opening.
4. Carefully guide and lower actuator into column.
If column lid plate does not seat properly:
• Rod may not be aligned with runner.
• Look through column access openings.
RISE Robotics of 24 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
• Gently guide rod into correct position.
• Once aligned, lower fully until lid plate seats flush.
Step 3 – Install Rod Pin
1. Align rod end with runner.
2. Orient rod pin so safety hole aligns properly.
3. Tap pin into place until flush.
4. Reinstall pin retainer using 3/16" hex key.
Step 4 – Reconnect Electrical Connectors
Reconnect all actuator electrical connections
securely.
Verify connectors are fully seated and properly
oriented.
Step 5 – Restore Power
1. Remove lifting device.
2. Remove gate ratchet strap.
3. Reconnect 48V battery.
4. Turn liftgate power ON.
5. Test gate operation.
Liftgate is now ready for service.
RISE Robotics of 25 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Warranty
Inspect Cylinder Piston Seals
Inspect the cylinder piston rod seals for scoring by
lower the platform all the way and inspect the
polished rod of the cylinder for any signs of
marinating, corrosion, or kinks that would
potentially affect effective operation.
Platform Movement Timing
Under normal operation, the platform should:
• Open or close fully within 5 to 10 seconds
• Raise or lower within 10 to 15 seconds, whether
loaded or unloaded
These ranges represent expected performance for
this PILOT model. Significant deviations from these
timings may indicate obstructions or maintenance
needs.
If the platform is moving noticeably slower than
expected:
• Perform a basic walkaround inspection of the
machine
• Look for any foreign objects, debris, or
structural interference that may be lodged in
the moving components
• If safe to do so, carefully remove any visible
obstructions
If the cause of abnormal timing cannot be visually
identified or the platform appears to be moving
too quickly, do not operate further. Instead, please
get in touch with RISE Robotics for support to
investigate and ensure the system is operating
safely and correctly.
Note: Production versions of this system will
include integrated diagnostic tools to help identify
timing anomalies and their causes. These tools will
be accessible via the mobile application.
Limited Warranty
Beltdraulic Railgate
Pre-Production Units
3 yrs Mechanical + 3 yrs Electric
Thank you for choosing RISE Robotics as your
partner in innovation. As a valued participant in our
pilot program, your Beltdraulic Railgate is part of a
pre-production initiative designed to optimize
performance in real-world applications. This unit is
a pre-production model intended for early
adopters. We are fully committed to addressing
any design issues that may arise during your
evaluation of the unit.
SUPPORT COMMITMENT
A 3-year limited support coverage backs your
Beltdraulic Railgate for all mechanical and electrical
components. While this is not a traditional warranty
in the commercial sense, RISE Robotics will provide
direct support, including onsite service from our
technical team, to promptly resolve any issues
encountered during the pilot period. This support
includes: Your Beltdraulic Railgate is backed by a 3-
year limited warranty support coverage for all
mechanical, electrical, and hydraulic components.
While this is not a traditional warranty in the
commercial sense, RISE Robotics will provide direct
support, including onsite service from our technical
team, to promptly resolve any issues encountered
during the pilot period. This support includes:
• Full coverage of any component failures
resulting from normal use
• Dispatch of RISE technicians or authorized
partners for field service
• No-cost replacement of failed parts (including
shipping)
• Close collaboration to ensure product feedback
is addressed swiftly
This coverage is available only to original pilot
participants, commencing from the date of
shipment from our facility.
PILOT SERVICE TERMS
Unlike a commercial warranty requiring claims
submission and authorization processes, all pilot
support requests should be directed to the RISE
RISE Robotics of 26 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Customer Success Team. There is no need to file
formal claims or return parts unless requested by
our engineers for evaluation.
Should your liftgate require service, please contact
us directly:
RISE Robotics
1 Union Square, Somerville, MA 02143
📞 (909) 744-4135
🌐 www.riserobotics.com
📧 liftgate_sales@riserobotics.com
🕗 Monday–Friday, 8:00 AM – 5:00 PM EST
WHAT’S NOT COVERED
This pilot coverage excludes:
• Damage due to misuse, abuse, or unauthorized
modifications
• Incidental or consequential damages such as
vehicle downtime, lost revenue, or operational
delays
• Cosmetic wear and tear or finish degradation
over time
As this product is still in development, your
participation is crucial in helping us refine and
improve the Beltdraulic Railgate. We deeply value
your insights and are committed to making this
pilot a success for you.
RISE Robotics of 27 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
Troubleshooting
RISE Robotics of 28 33 www.riserobotics.com
Troubleshooting Chart
Problem Possible Causes Possible Solution
The motor does not run when
the control switch is activated.
The battery is not on. Turn on the battery in the battery box.
Dead or low battery. Make sure battery is fully charged. Check for
loose or corroded battery connections.
Replace or recharge battery.
Corroded or loose wire
connections.
Check all wire connections on power unit
for corrosion or looseness. Replace
defective terminals with “heat shrink”
factory type terminals. Check main power
cable from batteries, to circuit breakers, to
cut-off switch, to power unit.
Blown circuit breaker(s). Reset or replace circuit breaker(s).
Blown 10 Amp fuse in power
unit box.
Replace, if fuse is blown. If problem
continues, check for shorts in the electrical
system.
Defective Control box
switch.
Check switch. Replace if defective.
Defective motor(s). If the motor is determined to be defective, it
should be replaced. Uncontrolled
overheating, loose connections, and
corrosion are typically causes of faulty
motors.
If a liftgate is installed on a semi-trailer, ensure the battery wire is at least
two-gauge or heavier. Smaller wires can reduce the voltage, potentially
leading to battery box faults or failures.
If the liftgate does not operate in freezing conditions, ensure the battery
box is dry and does not contain water.
The liftgate will not lower to the
ground.
Structural damage. Fix damage. Replace worn parts. Check
clearance between platform and dock
bumpers.
Defective control switch. Check switch. Replace if defective.
Low Voltage Recharge battery (if less than 9 volts).
Defective actuator motor Replace Cylinder.Beltdraulic™ Railgate RISE Robotics
RISE Robotics of 29 33 www.riserobotics.com
Troubleshooting Chart
Problem Possible Causes Possible Solution
The platform will not
raise, will not raise rated
capacity, or raise, but
drift down when the
control switch is
released.
Load capacity has
been exceeded.
Verify load capacity and adjust
load weight.
Structural damage. Replace damaged parts.
Low Voltage. Inspect the battery connection
terminals and check the battery’s
Voltage (9 Volts minimum).
Liftgate will not open. Platform operating area
is not clear.
Clear platform operating area.
Blown circuit breaker Check all connectors and
connections for worn or loose parts,
replace any worn terminals with “heat
shrink” factory terminals. Reset
circuit breaker.
Blown in-line fuse. Replace blown fuse with 10 Amp ATO
or ATC fuse.
Platform lowers
extremely slow.
Slide runners or wear
strips are dirty,
damaged, or need oil.
Clean columns and slide runners with
high-pressure washer. Replace slide
runners or wear strips if they are bent
or damaged.
Cylinder rod is scored,
pitted, or bent.
Replace cylinder.
Platform will not close
completely.
Twisted platform hinge
pin (hex pin).
Check to see if twisted by lowering
platform below column to see hex
pin. Check alignment of hex pin and
lower cylinder pin, should be in
between the 8 o’clock and 9 o’clock
position with platform open. If not,
replace by sawing pin in half and
removing pin and bushings. Replace
hex pin and both hex bushings
Closure cylinder
defective.
Replace cylinder. DO NOT repack or
dismantle.
Platform will not close
at all, motor does run.
Low Voltage Recharge battery (if less than 9
volts).
Motor overheat Wait for about 5 minutes for heat to
naturally dissipate.Beltdraulic™ Railgate RISE Robotics
Inspection Record
RISE Robotics of 30 33 www.riserobotics.com
RISE Robotics
Beltdraulic Liftgate Inspection Record
Date of Inspection Notes, observations, maintenance performed, etc.Beltdraulic™ Railgate RISE Robotics
RISE Robotics of 31 33 www.riserobotics.com
RISE Robotics
Beltdraulic Liftgate Inspection Record
Date of Inspection Notes, observations, maintenance performed, etc.Beltdraulic™ Railgate RISE Robotics
Notes
RISE Robotics of 32 33 www.riserobotics.comBeltdraulic™ Railgate RISE Robotics
RISE Robotics of 33 33 www.riserobotics.com
If you have any questions during installation, operation, or
maintenance of this liftgate, contact RISE Robotics for assistance.
RISE Robotics
1 Union Square,
Somerville, Massachusetts 02143
(909) 744-4135
Web: www.riserobotics.com
Email: liftgate_sales@riserobotics.com
Business Hours: 8:00 AM – 5:00 PM EST, Monday–Friday

[VISUALLY VERIFIED OCR PDF page 2]
Beltdraulic™ Railgate RISE Robotics

QUICK START GUIDE

1 swiTcH on ap

2 WAIT 30 SECONDS fg

3 HOLD UP SWITCH
ALIGN COLUMN ARROWS

See

4 HOLD CLOSE SWITCH

Wes
Toren

RISE Robotics 2 of 33 www.riserobotics.com


[VISUALLY VERIFIED OCR PDF page 3]
Beltdraulic™ Railgate a RISE Robotics

OPEN/CLOSE AT TOP
ONLY PULL HANDLE FOR OPEN

2

S

RISE Robotics 3 of 33 www.riserobotics.com


[VISUALLY VERIFIED OCR PDF page 7]
Beltdraulic™ Railgate

To prevent personal injury, clean up any

spilled fluids immediately. To avoid

tripping, do not leave tools or
components laying around in the work area.

‘i RISE Liftgates recommends not riding the

liftgate, however, if the delivery operation

requires it, make sure your footing is stable
before raising or lowering platform. Always stand
away from the edge. When on the ground, always
stand clear of liftgate when it is operating.

Even though the RISE Liftgate is easy to install,
the installation should be done with at least two
people.

Always use/set the truck’s parking brake before
operating the liftgate. Failure to follow this
recommendation can result in injury.

A Do not place hands or feet in pinch points.

ds Do not place your feet under the platform.

maintenance. or repair of products made by
occur because the installer!
owner! operator failed to observe basic safety rules or
operating instructions.
To prevent injury, the liftgate and its related
components should only be installed by a qualified
ins They should have knowledge and skill in
using lifting equipment and a cutting torch.

® main accidents involving the operation,

To prevent possible injuries due to improper
operation, make sure all decals are attached to
the liftgate and/or truck and are legible at all

times.

RISE Robotics

7 of 33

RISE Robotics

Safety Icons

@ se two people when lifting heavy objects

Damaged slaty sgn

BX “nish hazard (chock wheels)

A Fatrazara

me Detective or broken part

www.riserobotics.com


[VISUALLY VERIFIED OCR PDF page 8]
Beltdraulic™ Railgate

To prevent serious bodily injury,
ee) 3) keep sparks, lighted matches,

and open flames away from the
top of the battery, because battery gas can explode.
Always follow all the manufacturers’ safety
recommendations when working around the truck’s
battery.

Take precautions to avoid sparks coming into

contact with the truck’s fuel tank, brake lines,

wooden floor, or other flammable components.
Sparks can cause an explosion of combustible
materials, resulting in serious injury or death.

Never secure the power cable to anything

which allows it to contact sharp edges, other
“= wiring, the fuel tank, fuel lines, brake lines, air
lines, exhaust system, or any other object that could
cause the power cable to wear or be damaged. A cut
battery cable can cause sparks resulting in loss of
vehicle control, serious injury, or even death.

Always weld or use a cutting
torch in a well ventilated area and,
if in an enclosed area, vent the

fumes to the outside. Breathing the smoke and fumes

can cause serious injury.
Tack welds must be strong enough to hold the
weight of the individual components being held
in place. Insufficient tack welds may not hold
the parts in place, resulting in possible bodily harm.

Always follow all State and Federal health and
safety laws and/or local regulations when using
a welder or cutting torch. Also, follow all
manufacturer’s safety guidelines. If other people are
present during the installation of the liftgate, make
sure they remain clear of the cutting area and are
shielded from view of any welding. This will prevent
serious eye injury from the bright light.

To avoid eye injury, always wear eye protection

with the proper lens to protect your eyes.
A ‘suspended from the lifting equipment. Failure

of the lifting equipment could cause serious
crushing injuries. Do not remove the lifting equipment

until the liftgate is completely welded onto the truck
frame.

Failure to prevent the truck from moving
during the installation of the li
could result in a serious crushing injury.

Do not work under the liftgate while it is

RISE Robotics

8 of 33

RISE Robotics

To prevent personal injury, clean up any
spilled fluids immediately. To avoid

AA ies do not leave tools or

components laying around in the work area.
RISE Liftgates recommends not riding the
liftgate, however, if the delivery operation
requires it, make sure your footing is stable
before raising or lowering platform. Always stand
away from the edge. When on the ground, always
‘stand clear of liftgate whet operating.
Even though the RISE Liftgate is easy to install,

the installation should be done with at least two
people.

Always use/set the truck’s parking brake before
operating the liftgate. Failure to follow this
recommendation can result in injury.

A Do not place hands or feet in pinch points.

ds Do not place your feet under the platform.
® Most accidents involving the operation,
maintenance. or repair of products made by
RISE Robotics —_ occur because the installer/
‘owner! operator failed to observe basic safety rules or
operating instructions.
To prevent injury, the liftgate and its related
components should only be installed by a qualified
installer. They should have knowledge and skill in
using lifting equipment and a cutting torch.

To prevent possible injuries due to improper
operation, make sure all decals are attached to
the liftgate and/or truck and are legible at all

times.

www.riserobotics.com


[VISUALLY VERIFIED OCR PDF page 11]
Beltdraulic™ Railgate RISE Robotics
Nomenclature

Upper Shipping =
Support

H - Frame Column

Built-in
Brake, Backup,

and Parking Lights Operator Controls

Shipping Leg

Slide Runner
Platform

Support Chain

Platform
Shipping Leg

RISE Robotics 11 of 33 www.riserobotics.com
Identifikace uložené verze

SHA-256: cc19d432e22b09a991fa64d82e33964306d9f8b3be5700efef30f00ff7178363