RADIO TEST REPORT – 480657-1APFWL
Type of assessment:
MPE Calculation report
Manufacturer: Hardware Version Identification Number (HVIN):
Taiga Motors Inc A11638
Product Marketing Name (PMN): HMN:
Key module A11596
FCC ID: ISED certification number:
2A8MUA11638 28910-A11638
Specification:
FCC 47 CFR Part 1 Subpart I, §§1.1307, 1.1310
FCC 47 CFR Part 2 Subpart J, §2.1091
FCC KDB 447498 D01 General RF Exposure Guidance v06
ISED Canada RSS-102 Issue 5 Amendment 1, (February 2021)
RSS-102 Annex B - Declaration of RF Exposure Compliance
ATTESTATION: I attest that the information provided in Annex A is correct; that the Technical Brief was prepared and the information
contained therein is correct; that the device evaluation was performed or supervised by me; that applicable measurement methods and
evaluation methodologies have been followed; and that the device meets the SAR and/or RF field strength limits of RSS-102.
Date of issue: November 7, 2022
Abdoulaye Ndiaye, EMC/RF Specialist
Prepared by Signature
Nemko Canada Inc., a testing laboratory, is accredited by the Standards Council of Canada.
The tests included in this report are within the scope of this accreditation.
The SCC Accreditation Symbol is an official symbol of the Standards Council of Canada, used under licence.
SCC File Number: 15064 (Ottawa/Almonte); 151100 (Montreal); 151097 (Cambridge)
www.nemko.com FCC and RSS-102 Annex C – MPE Calculation; Date: May 2021
Section 1 MPE calculation
Lab locations
Company name Nemko Canada Inc.
Facilities Ottawa site: Montréal site: Cambridge site: Almonte site:
303 River Road 292 Labrosse Avenue 1-130 Saltsman Drive 1500 Peter Robinson Road
Ottawa, Ontario Pointe-Claire, Québec Cambridge, Ontario West Carleton, Ontario
Canada Canada Canada Canada
K1V 1H2 H9R 5L8 N3E 0B2 K0A 1L0
Tel: +1 613 737 9680 Tel: +1 514 694 2684 Tel: +1 519 650 4811 Tel: +1 613 256-9117
Fax: +1 613 737 9691 Fax: +1 514 694 3528
Test site identifier Organization Ottawa/Almonte Montreal Cambridge
FCC: CA2040 CA2041 CA0101
ISED: 2040A-4 2040G-5 24676
Website www.nemko.com
Limits of responsibility
Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples
and the date of issue of the report.
This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contained in this report are within Nemko Canada’s
ISO/IEC 17025 accreditation.
Copyright notification
Nemko Canada Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only.
Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties.
Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report.
© Nemko Canada Inc.
Report reference ID: 480657-1APFWL Page 2 of 3
Section 1 MPE calculation
Evaluation summary
1.1 MPE calculation for standalone transmission
1.1.1 References, definitions and limits
FCC §2.1091(d)
(2) (2) For operations within the frequency range of 300 kHz and 6 GHz (inclusive), the limits for maximum permissible exposure (MPE), derived
from whole-body SAR limits and listed in Table 1 in paragraph (e)(1) of this section, may be used instead of whole-body SAR limits as set forth
in paragraphs (a) through (c) of this section to evaluate the environmental impact of human exposure to RF radiation as specified in §1.1307(b)
of this part, except for portable devices as defined in §2.1093 of this chapter as these evaluations shall be performed according to the SAR
provisions in §2.1093.
Table 1.1-1: Table 1 to §1.1310(e)(1)—Limits for Maximum Permissible Exposure (MPE)
Frequency range Electric field strength Magnetic field strength Power density Averaging time
(MHz) (V/m) (A/m) (mW/cm2) (minutes)
(i) Limits for Occupational/Controlled Exposure
0.3–3.0 614 1.63 *(100) ≤6
3.0–30 1842 / f 4.89 / f *(900 / f2) <6
30–300 61.4 0.163 1.0 <6
300–1500 f / 300 <6
1500–100000 5 <6
(ii) Limits for General Population/Uncontrolled Exposure
0.3–1.34 614 1.63 *(100) <30
1.34–30 824 / f 2.19 / f *(180 / f2) <30
30–300 27.5 0.073 0.2 <30
300–1500 f / 1500 <30
1500–100000 1.0 <30
Notes: f = frequency in MHz. * = Plane-wave equivalent power density.
RSS-102, Section 4
For the purpose of this standard, Industry Canada has adopted the SAR and RF field strength limits established in Health Canada’s RF exposure
guideline, Safety Code 6:
Table 1.1-2: Table 4 to RSS-102— RF Field Strength Limits
Frequency range Electric field strength Magnetic field strength Power density Reference Period
(MHz) (V/m rms) (A/m rms) (W/m2) (minutes)
Limits for Controlled Environment
10–20 61.4 0.163 10 6
20–48 129.8 / ƒ 0.25 0.3444 / ƒ 0.25 44.72 / ƒ 0.5 6
48–100 49.33 0.1309 6.455 6
100–6000 15.60 ƒ 0.25 0.04138 ƒ 0.25 0.6455 ƒ 0.5 6
6000–15000 137 0.364 50 6
Limits for Uncontrolled Environment
10–20 27.46 0.0728 2 6
20–48 58.07 / ƒ 0.25 0.1540 / ƒ 0.25 8.944 / ƒ 0.5 6
48–300 22.06 0.05852 1.291 6
300–6000 3.142 ƒ 0.3417 0.008335 ƒ 0.3417 0.02619 ƒ 0.6834 6
6000–15000 61.4 0.163 10 6
Notes: ƒ = frequency in MHz.
Report reference ID: 480657-1APFWL Page 3 of 4
Section 1 MPE calculation
References, definitions and limits, continued
Equation from page 18 of OET Bulletin 65, Edition 97-01
𝑃𝐺
𝑆=
4𝜋𝑅 2
where: S = power density (mW/cm2 or W/m2)
P = power input to the antenna (mW or W)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (cm or m)
1.1.2 EUT technical information
Prediction frequency 13.56 MHz
Antenna type Custom air coil antenna
Antenna gain 0 dBi (included in Field Strength)
Number of antennas 1
Maximum transmitter power 52.0 dBµV/m (at 3 m)
Prediction distance (declared) 20 cm
1.1.3 MPE calculation
Fundamental transmit (prediction) frequency: 13.56 MHz
Maximum measured field strength at 3 m: 52.00 dBµV/m
Transmit duty cycle: 100 %
Maximum calculated average field strength: 52.00 dBµV/m
Single Antenna gain (typical): 0.00 dBi (included in Field Strength)
Number of antennae: 1
Total system gain: 0.00 dBi
FCC limit: ISED limit:
MPE limit for uncontrolled exposure at prediction frequency: 0.978933 mW/cm 2 0.200000 mW/cm 2
9.789334 W/m2 2.000000 W/m2
MPE limit for controlled exposure at prediction frequency: 4.894667 mW/cm 2 0.645500 mW/cm 2
48.946668 W/m2 6.455000 W/m2
Minimum calculated prediction distance for compliance: 20 cm 20 cm
Typical (declared) distance: 20 cm 20 cm
Average power density at prediction frequency: 0.0000000095 mW/cm 2 0.00000000946 mW/cm 2
0.000000095 W/m2 0.000000095 W/m2
Margin of Compliance for uncontrolled environment: 80.15 dB 73.25 dB
with Maximum allowable antenna gain: 80.15 dBi 73.25 dBi
Margin of Compliance for controlled environment: 87.14 dB 78.34 dB
with Maximum allowable antenna gain: 138.14 dBi 129.34 dBi
1.1.4 Verdict
The calculation is below the limit; therefore, the product is passing the RF Exposure requirements for the declared distance.
Report reference ID: 480657-1APFWL Page 4 of 5
Section 1 MPE calculation
1.1.5 RSS-102, Annex A - RF technical brief cover sheet
ISED certification number IC: 28910-A11638
Product marketing name (PMN) Key module
Hardware version identification number (HVIN) A11638
Firmware version identification number (FVIN) APP_KEY_v2_PROD_5.2.1.2-ddb808fb
Host marketing name (HMN) A11596
Applicant name Taiga Motors Inc
SAR/RF exposure test laboratory 2040G-5 (3 m semi anechoic chamber - Montréal)
☐ SAR Evaluation: Device Used in the Vicinity of the Human Head
☐ SAR Evaluation: Body-Worn Device and Body-Supported Device
Type of evaluation ☐ SAR Evaluation: Limb-Worn Device
☒ RF Exposure Evaluation
☐ Nerve Stimulation Exposure Evaluation (SPR-002)
Multiple transmitters: ☐ Yes ☒ No
Evaluated against exposure limits: ☐ General Public Use ☐ Controlled Use
Duty cycle used in evaluation: N/A %
SAR evaluation Separation distance: N/A mm
Standard used for evaluation: N/A
SAR value: N/A W/kg
☐ Measured ☐ Computed ☐ Calculated
Evaluated against exposure limits: ☐ General Public Use ☐ Controlled Use
Measurement distance: N/A m
Field Strength: N/A ☐ V/m (electric) ☐ A/m
(magnetic)
Nerve Stimulation Evaluation (SPR-002)
☐ Measured ☐ Computed ☐
Calculated
Exposure condition: ☐ Whole body/Torso/Head ☐ Leg
☐ Arm ☐ Hand/Foot
Evaluated against exposure limits: ☒ General Public Use ☐ Controlled Use
Duty cycle used in evaluation: 100 %
Operational frequency: 13.56 MHz
RF exposure evaluation Standard used for evaluation: Safety Code 6
Measurement distance: 0.2 m
RF value: ☒ W/m2 ☐ V/m ☐ A/m
0.000000095 ☐ Measured ☐ Computed ☒
Calculated
End of the test report
Report reference ID: 480657-1APFWL Page 5 of 5
[READING ORDER TEXT]
www.nemko.com
Nemko Canada Inc., a testing laboratory, is accredited by the Standards Council of Canada.
The tests included in this report are within the scope of this accreditation.
The SCC Accreditation Symbol is an official symbol of the Standards Council of Canada, used under licence.
SCC File Number: 15064 (Ottawa/Almonte); 151100 (Montreal); 151097 (Cambridge)
FCC and RSS-102 Annex C – MPE Calculation; Date: May 2021
Choose Scandinavian trust
RADIO TEST REPORT – 480657-1APFWL
Type of assessment:
MPE Calculation report
Manufacturer: Hardware Version Identification Number (HVIN):
Taiga Motors Inc A11638
Product Marketing Name (PMN): HMN:
Key module A11596
FCC ID: ISED certification number:
2A8MUA11638 28910-A11638
Specification:
FCC 47 CFR Part 1 Subpart I, §§1.1307, 1.1310
FCC 47 CFR Part 2 Subpart J, §2.1091
FCC KDB 447498 D01 General RF Exposure Guidance v06
ISED Canada RSS-102 Issue 5 Amendment 1, (February 2021)
RSS-102 Annex B - Declaration of RF Exposure Compliance
ATTESTATION: I attest that the information provided in Annex A is correct; that the Technical Brief was prepared and the information
contained therein is correct; that the device evaluation was performed or supervised by me; that applicable measurement methods and
evaluation methodologies have been followed; and that the device meets the SAR and/or RF field strength limits of RSS-102.
Date of issue: November 7, 2022
Abdoulaye Ndiaye, EMC/RF Specialist
Prepared by SignatureSection 1 MPE calculation
Report reference ID: 480657-1APFWL Page 2 of 3
Lab locations
Company name Nemko Canada Inc.
Facilities Ottawa site:
303 River Road
Ottawa, Ontario
Canada
K1V 1H2
Tel: +1 613 737 9680
Fax: +1 613 737 9691
Montréal site:
292 Labrosse Avenue
Pointe-Claire, Québec
Canada
H9R 5L8
Tel: +1 514 694 2684
Fax: +1 514 694 3528
Cambridge site:
1-130 Saltsman Drive
Cambridge, Ontario
Canada
N3E 0B2
Tel: +1 519 650 4811
Almonte site:
1500 Peter Robinson Road
West Carleton, Ontario
Canada
K0A 1L0
Tel: +1 613 256-9117
Test site identifier Organization Ottawa/Almonte Montreal Cambridge
FCC: CA2040 CA2041 CA0101
ISED: 2040A-4 2040G-5 24676
Website www.nemko.com
Limits of responsibility
Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples
and the date of issue of the report.
This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contained in this report are within Nemko Canada’s
ISO/IEC 17025 accreditation.
Copyright notification
Nemko Canada Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only.
Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties.
Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report.
© Nemko Canada Inc.Section 1 MPE calculation
Report reference ID: 480657-1APFWL Page 3 of 4
Evaluation summary
1.1 MPE calculation for standalone transmission
1.1.1 References, definitions and limits
FCC §2.1091(d)
(2) (2) For operations within the frequency range of 300 kHz and 6 GHz (inclusive), the limits for maximum permissible exposure (MPE), derived
from whole-body SAR limits and listed in Table 1 in paragraph (e)(1) of this section, may be used instead of whole-body SAR limits as set forth
in paragraphs (a) through (c) of this section to evaluate the environmental impact of human exposure to RF radiation as specified in §1.1307(b)
of this part, except for portable devices as defined in §2.1093 of this chapter as these evaluations shall be performed according to the SAR
provisions in §2.1093.
Table 1.1-1: Table 1 to §1.1310(e)(1)—Limits for Maximum Permissible Exposure (MPE)
Frequency range
(MHz)
Electric field strength
(V/m)
Magnetic field strength
(A/m)
Power density
(mW/cm2)
Averaging time
(minutes)
(i) Limits for Occupational/Controlled Exposure
0.3–3.0 614 1.63 *(100) ≤6
3.0–30 1842 / f 4.89 / f *(900 / f2
) <6
30–300 61.4 0.163 1.0 <6
300–1500 f / 300 <6
1500–100000 5 <6
(ii) Limits for General Population/Uncontrolled Exposure
0.3–1.34 614 1.63 *(100) <30
1.34–30 824 / f 2.19 / f *(180 / f2
) <30
30–300 27.5 0.073 0.2 <30
300–1500 f / 1500 <30
1500–100000 1.0 <30
Notes: f = frequency in MHz. * = Plane-wave equivalent power density.
RSS-102, Section 4
For the purpose of this standard, Industry Canada has adopted the SAR and RF field strength limits established in Health Canada’s RF exposure
guideline, Safety Code 6:
Table 1.1-2: Table 4 to RSS-102— RF Field Strength Limits
Frequency range
(MHz)
Electric field strength
(V/m rms)
Magnetic field strength
(A/m rms)
Power density
(W/m2)
Reference Period
(minutes)
Limits for Controlled Environment
10–20 61.4 0.163 10 6
20–48 129.8 / ƒ 0.25 0.3444 / ƒ 0.25 44.72 / ƒ 0.5 6
48–100 49.33 0.1309 6.455 6
100–6000 15.60 ƒ 0.25 0.04138 ƒ 0.25 0.6455 ƒ 0.5 6
6000–15000 137 0.364 50 6
Limits for Uncontrolled Environment
10–20 27.46 0.0728 2 6
20–48 58.07 / ƒ 0.25 0.1540 / ƒ 0.25 8.944 / ƒ 0.5 6
48–300 22.06 0.05852 1.291 6
300–6000 3.142 ƒ 0.3417 0.008335 ƒ 0.3417 0.02619 ƒ 0.6834 6
6000–15000 61.4 0.163 10 6
Notes: ƒ= frequency in MHz.Section 1 MPE calculation
Report reference ID: 480657-1APFWL Page 4 of 5
References, definitions and limits, continued
Equation from page 18 of OET Bulletin 65, Edition 97-01
𝑆 =
𝑃𝐺
4𝜋𝑅2
where: S = power density (mW/cm2 or W/m2)
P = power input to the antenna (mW or W)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (cm or m)
1.1.2 EUT technical information
Prediction frequency 13.56 MHz
Antenna type Custom air coil antenna
Antenna gain 0 dBi (included in Field Strength)
Number of antennas 1
Maximum transmitter power 52.0 dBµV/m (at 3 m)
Prediction distance (declared) 20 cm
1.1.3 MPE calculation
Fundamental transmit(prediction) frequency: 13.56 MHz
Maximummeasured field strength at3 m: 52.00 dBµV/m
Transmitduty cycle: 100 %
Maximumcalculated averagefield strength: 52.00 dBµV/m
SingleAntenna gain (typical): 0.00 dBi (included in Field Strength)
Number of antennae: 1
Total systemgain: 0.00 dBi
FCC limit: ISED limit:
MPElimit for uncontrolled exposureatprediction frequency: 0.978933 mW/cm2 0.200000 mW/cm2
9.789334 W/m2 2.000000 W/m2
MPElimit for controlled exposureatprediction frequency: 4.894667 mW/cm2 0.645500 mW/cm2
48.946668 W/m2 6.455000 W/m2
Minimumcalculated prediction distancefor compliance: 20 cm 20 cm
Typical (declared) distance: 20 cm 20 cm
Average power density at prediction frequency: 0.0000000095 mW/cm2 0.00000000946 mW/cm2
0.000000095 W/m2 0.000000095 W/m2
Margin of Compliancefor uncontrolled environment: 80.15 dB 73.25 dB
with Maximumallowableantenna gain: 80.15 dBi 73.25 dBi
Margin of Compliancefor controlled environment: 87.14 dB 78.34 dB
with Maximumallowableantenna gain: 138.14 dBi 129.34 dBi
1.1.4 Verdict
The calculation is below the limit; therefore, the product is passing the RF Exposure requirements for the declared distance.Section 1 MPE calculation
Report reference ID: 480657-1APFWL Page 5 of 5
1.1.5 RSS-102, Annex A - RF technical brief cover sheet
ISED certification number IC: 28910-A11638
Product marketing name (PMN) Key module
Hardware version identification number (HVIN) A11638
Firmware version identification number (FVIN) APP_KEY_v2_PROD_5.2.1.2-ddb808fb
Host marketing name (HMN) A11596
Applicant name Taiga Motors Inc
SAR/RF exposure test laboratory 2040G-5 (3 m semi anechoic chamber - Montréal)
Type of evaluation
☐ SAR Evaluation: Device Used in the Vicinity of the Human Head
☐ SAR Evaluation: Body-Worn Device and Body-Supported Device
☐ SAR Evaluation: Limb-Worn Device
☒ RF Exposure Evaluation
☐ Nerve Stimulation Exposure Evaluation (SPR-002)
SAR evaluation
Multiple transmitters: ☐ Yes ☒ No
Evaluated against exposure limits: ☐ General Public Use ☐ Controlled Use
Duty cycle used in evaluation: N/A %
Separation distance: N/A mm
Standard used for evaluation: N/A
SAR value: N/A W/kg
☐ Measured ☐ Computed ☐ Calculated
Nerve Stimulation Evaluation (SPR-002)
Evaluated against exposure limits: ☐ General Public Use ☐ Controlled Use
Measurement distance: N/A m
Field Strength: N/A ☐ V/m (electric) ☐ A/m
(magnetic)
☐ Measured ☐ Computed ☐
Calculated
Exposure condition: ☐ Whole body/Torso/Head ☐ Leg
☐ Arm ☐ Hand/Foot
RF exposure evaluation
Evaluated against exposure limits: ☒ General Public Use ☐ Controlled Use
Duty cycle used in evaluation: 100 %
Operational frequency: 13.56 MHz
Standard used for evaluation: Safety Code 6
Measurement distance: 0.2 m
RF value:
0.000000095
☒ W/m2 ☐ V/m ☐ A/m
☐ Measured ☐ Computed ☒
Calculated
End of the test reportIdentifikace uložené verze
SHA-256: 29441aff206c6e22d21bea7ee37186577e1359399cc3fa28be4c4aa0343320a9