← Přehled firem
Získáno 24. 10. 2026 · 22:22
VICTORY   ADVANCED     TECHNOLOGIES       //   INDUSTRIAL    MOTORS




INSTALLATION       &   MAINTENANCE        MANUAL      ·   FIRST   EDITION




REFLEX SMART
HOSE REEL
HOSE REEL MOTOR
          MOTOR ·· HRMA-56S
                   HRMA-56S



Extreme-service, explosion-proof smart electric motor for industrial
hose reels operating in hazardous locations.

 2/3 HP     500 RPM      IP68 · NEMA 6P        EX DB IIA T3 GB


 NEMA 56S FRAME



VICTORY ADVANCED TECHNOLOGIES INC.
                                               DOC · UM-HRMA-56S-12V-SMT · REV 1
VICTORYMOTOR.CA · 1-888-653-7380
                                                                       HRMA-56S-12V-SMT


     01       SAFETY    &   SUPPORT


SUPPORT
Technical product support is available by phone, or through the request form at
victorymotor.ca/contact.


      CONTACT TECHNICAL SUPPORT

   BU SI NES S HOU RS       1-888-653-7380 Mon–Fri · 8:00 AM–4:00 PM EST

   24 / 7 LI NE                           1-506-608-8136 any hour, any day

   ON LI NE         victorymotor.ca/contact submit a support request



PRODUCT WARNINGS


      READ BEFORE INSTALLATION & SERVICE

       Do not open equipment when energized.

       After de-energizing, delay 5 minutes before opening — or do not open when an
       explosive atmosphere may be present.

       Cable entry devices must be suitable for Ex db IIA T3 Gb use, and the conditions
       of their safe use must be followed.

       Do not wear loose clothing when working on or near the motor.
       Motor must be powered by a suitable interlock device that disables the system
       when the vehicle is in motion and prevents unintentional use.

       Do not service the motor when energized. Unintentional operation while
       servicing may result in serious injury or death.




02 — SAFETY & SUPPORT                                            UM-HRMA-56S-12V-SMT
                                                                                HRMA-56S-12V-SMT


      02      COVERAGE


LIMITED WARRANTY
Victory Advanced Technologies smart electric motor system.


   WARRANTY TERM


   4 YEARS free from defects in material and workmanship, from the
           date of manufacture.


If a motor fails within the limited warranty period, please call us with your motor's
serial number. We will generate an RMA number, provide return shipping
information, and issue a full replacement motor — no questions asked.


   START A WARRANTY CLAIM

   Call 1-888-653-7380 (Mon–Fri, 8:00 AM–4:00 PM EST) or 1-506-608-8136 any
   hour, any day. Have the motor's serial number ready.


        WARRANTY BECOMES VOID IF

         The product is improperly installed, modi{ed, damaged, or abused.

         The product is used for applications other than its intended use.


Victory Advanced Technologies is not liable for material, labour, or contingent liabilities arising
out of the improper use or function of any product.




03 — LIMITED WARRANTY                                                     UM-HRMA-56S-12V-SMT
                                                                         HRMA-56S-12V-SMT


      03      TECHNICAL       DATA


PRODUCT SPECIFICATIONS
HRMA-56S-12V-SMT — smart inverter hose reel motor.

PO WE R                                                                             2/3 HP

SP EE D                                                                          500 RPM

DU TY                                                                             5 Minutes

IN GR ESS P ROT ECT IO N                                                IP68 & NEMA 6P

FR AM E S IZ E                                                                NEMA 56S

CO MM UTA TI ON                                                       Smart Inverter



      PART     NUMBER     BREAKDOWN



        HRMA                    56S                     12V                    SMT
        HOSE REEL               FRAME                  NOMINAL                   SMART
          MOTOR                 SIZE                   VOLTAGE                 INVERTER



Each segment of the part number identi{es a core attribute of the motor, from the product
family through to the smart-inverter commutation package.


   DIRECT REPLACEMENT

   The HRMA-56S-12V-SMT is a plug & play replacement for traditional brushed DC
   utility motors — replacing the brushes with a smart inverter so the motor lasts
   longer and runs an internal computer for smart functionality.




04 — SPECIFICATIONS                                                 UM-HRMA-56S-12V-SMT
                                                                         HRMA-56S-12V-SMT


       04      INSTALLATION


INSTALLATION
Mounting the motor & drive coupling. Steps 1–2 of 8.
STEP
            Use a stainless steel 3/16″ wide #605 Woodruff key to secure the gear or
1           sprocket to the end of the shaft.




                     FI G. 1 — 3/16 ″ # 605 WOO DRU FF K EY




STEP
            Slide the spur gear or chain drive sprocket over the shaft and lock it in place.
2




                      FI G. 2 — GEAR / SPRO CKE T F ITME NT




05 — INSTALLATION                                                   UM-HRMA-56S-12V-SMT
                                                                       HRMA-56S-12V-SMT


       04      INSTALLATION


MOUNTING
Fixing the motor to the reel frame. Steps 3–4 of 8.
STEP
            Place four 2.5″ long 3/8″-16 carriage bolts on the mounting plate. Slide the
3           motor onto the mounting bolts.




                   FI G. 3 — 2.5″ 3/ 8″-1 6 C ARRI AGE BO LTS




STEP
            Secure the motor with four 3/8″ stainless steel washers and four 3/8″-16
4           stainless steel nuts. Nylon lock-nuts may be used.




                 FI G. 4 — 3/8″ -16 WAS HER & N UT




06 — INSTALLATION                                                 UM-HRMA-56S-12V-SMT
                                                                      HRMA-56S-12V-SMT


       04     INSTALLATION


WIRING
Accessing the junction box & power connections. Steps 5–6 of 8.
STEP
            Remove the six 1/4″-20 screws from the lid to access the integrated junction
5           box.




                   FI G. 5 — 1/4″ -20 LID BO LTS




STEP
            Connect a red wire from a 70 A breaker or fuse to the +12V terminal. Connect
6           a black wire with a high-current connection to chassis ground at the GND
            terminal. Ensure the cable entry uses an appropriately rated gland.




                   FI G. 6 — +12V / GND POW ER TERM INA LS




07 — INSTALLATION                                                UM-HRMA-56S-12V-SMT
                                                                          HRMA-56S-12V-SMT


       04      INSTALLATION


CONFIGURATION
Signal wiring & junction box map. Steps 7–8 of 8.
STEP
            Con{gure the desired reel-in speed and direction of rotation using the
7           con{guration switches. 12V sourcing inputs between 16 and 24 AWG connect
            to the lever-lock terminals in the lower-middle of the junction box. The three
            LED indicators illuminate when the corresponding input signal is active. The
            test mode switch suppresses motor operation so input wiring can be veri{ed.




  FI G. 7 — JUNC TIO N BO X L AYO UT                      TE RMIN ALS · S WIT CHES · INPU TS



STEP
            Replace the lid and all six 1/4″-20 stainless steel bolts with washers.
8
               15 Torque all six lid bolts to a minimum of 15 N·m to maintain the
                        enclosure's ingress and explosion-proof rating.
               N·m



08 — CONFIGURATION                                                   UM-HRMA-56S-12V-SMT
                                                                          HRMA-56S-12V-SMT


     05     OPERATION


USAGE
A brushless replacement for traditional brushed DC utility motors.

On power-up the motor boots for approximately 10 seconds when 12V is applied to
the power terminals. On boot it treats the starting position as “all the way in.” When
reeling in, the motor applies a speed limit set by the rotary switch. If the hose is
close to the starting position, the speed limit is reduced further to gently return to a
fully stowed position.

     STATUS       LED   REFERENCE


                                     Booting — approximately 10 seconds after 12V is
          RED   SOLID
                                     applied.

          GREEN    BLINKING          Ready for operation.

          RED   BLINKING             A fault has been detected.

          GREEN    SOLID             Motor is actively applying torque.


  BA SI C R EE L-O UT                            SM AR T R EE L-O UT

  Pressing the reel-out button applies           The controller applies short bursts of
  maximum torque in the reel-out                 torque to assist the user when
  direction.                                     acceleration is detected.


   USB TYPE-C ACCESS PORT

   Use the USB port to apply software updates in the {eld and to access more in-
   depth features or con{guration settings.




09 — USAGE                                                        UM-HRMA-56S-12V-SMT
                                                                       HRMA-56S-12V-SMT


     06     SERVICE


MAINTENANCE
Keeping the drive-train healthy in the {eld.

The drive-train should be regularly inspected for debris that could damage
components. Failure to do so can result in broken gears, sprockets, chains, or
other critical drive-train components.

Squeaking or signi{cant variation in drum speed indicates that the reel or motor are
rubbing. If no obstructions or obvious signs of wear are present, apply a lubricant to
the shaft of the motor.


     ROUTINE      INSPECTION        CHECKLIST


     Inspect the drive-train for debris, obstructions, and buildup.

     Check gears, sprockets, and chains for wear or damage.

     Listen for squeaking or variation in drum speed — a sign of rubbing.

     With no obstructions or wear present, apply lubricant to the motor shaft.

     Con{rm all six lid bolts remain torqued to a minimum of 15 N·m.


   BEFORE ANY SERVICE

   De-energize the motor and wait 5 minutes before opening. Never service the
   motor while energized.




10 — MAINTENANCE                                                 UM-HRMA-56S-12V-SMT
                                                             HRMA-56S-12V-SMT


     07     FIELD    LOG


NOTES
Installation date, serial number, and service records.




11 — NOTES                                               UM-HRMA-56S-12V-SMT
               VICTORY       ADVANCED     TECHNOLOGIES


       INDUSTRIAL MOTORS
    Drawing on 38 years of experience in Oil & Gas electronic design and
    manufacturing — a new line of Extreme-Service, Explosion-Proof (Ex)
   electric motors for hose reels, pumps, and actuators used in hazardous
                                   locations.

Plug & Play direct replacement            Fully potted, water & vapour proof
Custom OEM designs available              Easy remote-control interface
Light weight                              Four-year no-hassle warranty
International OEM support                 Distributor support


          www.VICTORYmotor.ca
                   Victory Advanced Technologies Inc.
         604 Rothesay Ave, Saint John NB, Canada · E2H 2H1
           1-888-653-7380 · sales@victoryadvancedtech.com




           DOC · UM-HRMA-56S-12V-SMT · REV 1 · JULY 2026


[READING ORDER TEXT]
I N S T A L L A T I O N & M A I N T E N A N C E M A N U A L · F I R S T E D I T I O N
REFLEX SMART
HOSE REEL MOTOR · HRMA-56S HOSE REEL MOTOR · HRMA-56S
Extreme-service, explosion-proof smart electric motor for industrial
hose reels operating in hazardous locations.
2/3 HP 500 RPM IP68 · NEMA 6P EX DB IIA T3 GB
NEMA 56S FRAME
VI CTO RY ADV ANC ED TEC HNO LOG IES // IN DUS TRI AL MOT ORS
VICTORY ADVANCED TECHNOLOGIES INC.
VICTORYMOTOR.CA · 1-888-653-7380
DOC · UM-HRMA-56S-12V-SMT · REV 101 S AF ETY & SU PPO RT
SUPPORT
Technical product support is available by phone, or through the request form at
victorymotor.ca/contact.
PRODUCT WARNINGS
CONTACT TECHNICAL SUPPORT
BUSINESS HOURS 1-888-653-7380 Mon–Fri · 8:00 AM–4:00 PM EST
24 / 7 LINE 1-506-608-8136 any hour, any day
ONLINE victorymotor.ca/contact submit a support request
READ BEFORE INSTALLATION & SERVICE
Do notopen equipment when energized.
After de-energizing, delay5minutesbefore opening — or do not open when an
explosive atmosphere may be present.
Cable entry devices must be suitable forExdbIIAT3Gbuse, and the conditions
of their safe use must be followed.
Do not wear loose clothing when working on or near the motor.
Motor must be powered by a suitable interlockdevicethat disables the system
when the vehicle is in motion and prevents unintentional use.
Do not service the motor when energized. Unintentional operation while
servicing may result inseriousinjuryordeath.
HRMA-56S-12V-SMT
02 — SAFETY & SUPPORT UM-HRMA-56S-12V-SMT02 C OV ERA GE
LIMITED WARRANTY
Victory Advanced Technologies smart electric motor system.
If a motor fails within the limited warranty period, please call us with your motor's
serialnumber. We will generate anRMAnumber, provide return shipping
information, and issue afullreplacementmotor— no questions asked.
START A WARRANTY CLAIM
Call 1-888-653-7380 (Mon–Fri, 8:00 AM–4:00 PM EST) or1-506-608-8136 any
hour, any day. Have the motor's serial number ready.
Victory Advanced Technologies is not liable for material, labour, or contingent liabilities arising
out of the improper use or function of any product.
WARRANTY TERM
4 YEARS free from defects in material and workmanship,from the
date of manufacture.
WARRANTY BECOMES VOID IF
The product is improperly installed,modi{ed,damaged,orabused.
The product is used for applications otherthanitsintendeduse.
HRMA-56S-12V-SMT
03 — LIMITED WARRANTY UM-HRMA-56S-12V-SMT03 T EC HNI CA L D ATA
PRODUCT SPECIFICATIONS
HRMA-56S-12V-SMT — smart inverter hose reel motor.
POWER 2/3 HP
SPEED 500 RPM
DUTY 5 Minutes
INGRESS PROTECTION IP68 & NEMA 6P
FRAME SIZE NEMA 56S
COMMUTATION Smart Inverter
PA RT NU MB ER BRE AK DOW N
Each segment of the part number identi{es a core attribute of the motor, from the product
family through to the smart-inverter commutation package.
DIRECT REPLACEMENT
The HRMA-56S-12V-SMT is a plug & play replacement for traditional brushed DC
utility motors — replacing the brushes with a smart inverter so the motor lasts
longer and runs an internal computer for smart functionality.
HRMA
HOSE REEL
MOTOR
56S
FRAME
SIZE
12V
NOMINAL
VOLTAGE
SMT
SMART
INVERTER
HRMA-56S-12V-SMT
04 — SPECIFICATIONS UM-HRMA-56S-12V-SMT04 I NS TAL LA TIO N
INSTALLATION
Mounting the motor & drive coupling. Steps 1–2 of 8.
Use a stainless steel 3/16″ wide#605Woodruffkeyto secure the gear or
sprocket to the end of the shaft.
Slide the spurgearorchaindrivesprocketover the shaft and lock it in place.
STEP
1
FIG. 1 — 3/16″ #605 WOODRUFF KEY
STEP
2
FIG. 2 — GEAR / SPROCKET FITMENT
HRMA-56S-12V-SMT
05 — INSTALLATION UM-HRMA-56S-12V-SMT04 I NS TAL LA TIO N
MOUNTING
Fixing the motor to the reel frame. Steps 3–4 of 8.
Place four 2.5″ long3/8″-16carriageboltson the mounting plate. Slide the
motor onto the mounting bolts.
Secure the motor with four3/8″ stainlesssteelwashersand four 3/8″-16
stainlesssteelnuts. Nylon lock-nuts may be used.
STEP
3
FIG. 3 — 2.5″ 3/8″-16 CARRIAGE BOLTS
STEP
4
FIG. 4 — 3/8″-16 WASHER & NUT
HRMA-56S-12V-SMT
06 — INSTALLATION UM-HRMA-56S-12V-SMT04 I NS TAL LA TIO N
WIRING
Accessing the junction box & power connections. Steps 5–6 of 8.
Remove the six 1/4″-20screwsfrom the lid to access the integrated junction
box.
Connect a redwirefrom a 70Abreakerorfuseto the +12Vterminal. Connect
a blackwirewith a high-current connection to chassis ground at the GND
terminal. Ensure the cable entry uses an appropriately rated gland.
STEP
5
FIG. 5 — 1/4″-20 LID BOLTS
STEP
6
FIG. 6 — +12V / GND POWER TERMINALS
HRMA-56S-12V-SMT
07 — INSTALLATION UM-HRMA-56S-12V-SMT04 I NS TAL LA TIO N
CONFIGURATION
Signal wiring & junction box map. Steps 7–8 of 8.
Con{gure the desired reel-in speed and direction of rotation using the
con{guration switches. 12Vsourcinginputsbetween 16 and 24 AWG connect
to the lever-lock terminals in the lower-middle of the junction box. The three
LED indicators illuminate when the corresponding input signal is active. The
testmodeswitchsuppresses motor operation so input wiring can be veri{ed.
Replace the lid and all six 1/4″-20stainlesssteelboltswith washers.
15
N·m
Torque all six lid bolts to a minimumof15N·mto maintain the
enclosure's ingress and explosion-proof rating.
STEP
7
FIG. 7 — JUNCTION BOX LAYOUT TERMINALS · SWITCHES · INPUTS
STEP
8
HRMA-56S-12V-SMT
08 — CONFIGURATION UM-HRMA-56S-12V-SMT05 O PE RAT IO N
USAGE
A brushless replacement for traditional brushed DC utility motors.
On power-up the motor boots for approximately10 seconds when 12V is applied to
the power terminals. On boot it treats the starting position as “all the way in.” When
reeling in, the motor applies a speed limit set by the rotary switch. If the hose is
close to the starting position, the speed limit is reduced further to gently return to a
fully stowed position.
ST AT US LE D R EFE RE NCE
RED SOLID
Booting — approximately 10 seconds after 12V is
applied.
GREEN BLINKING Ready for operation.
RED BLINKING A fault has been detected.
GREEN SOLID Motor is actively applying torque.
BASIC REEL-OUT
Pressing the reel-out button applies
maximum torque in the reel-out
direction.
SMART REEL-OUT
The controller applies short bursts of
torque to assist the user when
acceleration is detected.
USB TYPE-C ACCESS PORT
Use the USB port to applysoftware updates in the {eld and to access more in-
depth features or con{guration settings.
HRMA-56S-12V-SMT
09 — USAGE UM-HRMA-56S-12V-SMT06 S ER VIC E
MAINTENANCE
Keeping the drive-train healthy in the {eld.
The drive-train should be regularly inspected for debris that could damage
components. Failure to do so can result inbroken gears, sprockets, chains, or
other critical drive-train components.
Squeaking or signi{cant variation in drum speed indicates that the reel or motor are
rubbing. If no obstructions or obvious signs of wear are present, apply a lubricant to
the shaft of the motor.
RO UT INE I NSP ECT IO N C HE CKL IS T
BEFORE ANY SERVICE
De-energize the motor and wait 5 minutes before opening. Never service the
motor while energized.
Inspect the drive-trainfor debris, obstructions, and buildup.
Check gears, sprockets, and chains for wearordamage.
Listen for squeakingor variation in drum speed — a sign of rubbing.
With no obstructions or wear present, apply lubricanttothemotorshaft.
Con{rm all six lid bolts remain torqued to a minimumof15N·m.
HRMA-56S-12V-SMT
10 — MAINTENANCE UM-HRMA-56S-12V-SMT07 F IE LD LO G
NOTES
Installation date, serial number, and service records.
HRMA-56S-12V-SMT
11 — NOTES UM-HRMA-56S-12V-SMTV I C T O R Y A D V A N C E D T E C H N O L O G I E S
INDUSTRIAL MOTORS
Drawing on 38 years of experience in Oil & Gas electronic design and
manufacturing — a new line of Extreme-Service, Explosion-Proof (Ex)
electric motors for hose reels, pumps, and actuators used in hazardous
locations.
www.VICTORYmotor.ca
Victory Advanced Technologies Inc.
604 Rothesay Ave, Saint John NB, Canada · E2H 2H1
1-888-653-7380 · sales@victoryadvancedtech.com
Plug & Play direct replacement Fully potted, water & vapour proof
Custom OEM designs available Easy remote-control interface
Light weight Four-year no-hassle warranty
International OEM support Distributor support
DOC · UM-HRMA-56S-12V-SMT · REV 1 · JULY 2026
Identifikace uložené verze

SHA-256: 080a2a12d550d6e49e23b5cb2c977bc7a5fa1abdef72ee1545077c379a0302bc