ZDROJOVÝ PODKLAD
Uložený text
https://drive.google.com/file/d/16IXWRvvZ1j11ZDqFqmGjD-O4oI1Abf7V/view?usp=drive_link ↗ TAIGA MOTORS INC.
ALUMINUM CASTING SPECIFICATION Page 1 / 7
Rév. 01
A. SCOPE AND DESCRIPTION
This specification has the objective to define the level of acceptance for external and internal
discontinuities, surface roughness and other common casting defects. This specification also defines the
different standards that the products must meet from a chemical composition and mechanical properties
standpoint. This document is applicable to any machined or unmachined aluminum part obtained from
the gravity or the die casting process. The supplier is expected to obtain the latest revision of any standard
referenced herein. This specification supersedes any previous casting specification produced by TAIGA.
B. FUNCTIONNAL CLASSIFICATION
The level of quality required will be defined based on the function class of the part which goes as follow:
• Function class 1: Castings with safety requirements.
• Function class 2: Castings statically and dynamically loaded and/or surfaces with special functional
requirements.
• Function class 3: Castings not included in classes 1 or 2 without specific functional requirements.
The Function class will define the Quality level applicable for discontinuities. There are two general types
of discontinuities that occur during the casting process. They are:
i. Internal Defects
ii. External defects
C. EXTERNAL DEFECTS
Machined and unmachined faces must offer a homogenous appearance and must be free of cracks or
other faults which could impair the fit/function of the component and/or subsequent machining
operations. Coupons, flash, burrs, material residues, fractures, cracks, signs of overheating and scorches,
creases, cavities, depressions and cold shots which restrict the fit/function are inadmissible. They must
be eliminated by suitable measures taken by the supplier.
Any cast part supplied to TAIGA must fall within the acceptable limits as defined below, unless otherwise
specified on 2D drawing:
Function Class 1:
1. Reference area 100 mm2 (square shaped)
2. Number of pores per Reference area ≤ 10
3. Maximum 8 pores up to Ø 0.1 mm
4. Maximum 2 pores up to Ø 0.2 mm
Function Class 2:
1. Reference area 100 mm2 (square shaped)
2. Number of pores per Reference area ≤ 15
3. Maximum 12 pores up to Ø 0.3 mm
4. Maximum 3 pores up to Ø 0.5 mm
TAIGA MOTORS INC.
ALUMINUM CASTING SPECIFICATION Page 2 / 7
Rév. 01
Function Class 3:
1. Reference area 100 mm2 (square shaped)
2. Number of pores per Reference area ≤ 20
3. Maximum 14 pores up to Ø 0.5 mm
4. Maximum 6 pores up to Ø 1.0 mm
For all of the 3 Function Class no surface faults are permitted within an area equal to twice the diameter
of a threaded hole. Furthermore, through porosities (i.e. porosities open to two surfaces) are
unacceptable for any casting supplied to TAIGA. Blind porosities (i.e. porosities open to one surface)
exceeding the requirements of Section C are also unacceptable. Any leak tightness requirement will be
specified on the 2D drawing.
D. INTERNAL DEFECTS
Radiographic inspection of Internal defects/discontinuities must be performed as per ASTM E94 Standard
Guide for Radiographic Examination Using Industrial Radiographic Film. IQI (Image Quality Indicator) must
be present on all Radiographs produced by the supplier to testify to the level of detail and validate the
quality of the radiographs. Unless otherwise specified the minimum IQI level is 2%. See Annex A for more
information.
The acceptance criteria developed by Taiga (Quality Grades) are based on the Reference Radiographs from
the following standards. Areas to be inspected shall be identified on the 2D drawings.
• For die cast parts: ASTM E505-22 Standard Reference Radiographs for Inspection of Aluminum and
Magnesium Die Castings. The different discontinuity levels are ranked on a scale of 1 to 4.
• For gravity cast parts: ASTM E155-20 Standard Reference Radiographs for Inspection of Aluminum
and Magnesium Castings. The different discontinuity levels are ranked on a scale of 1 to 8.
Taiga 2D drawings will typically define the Function Class Level and the Quality Grade required on the
entire part based on Table 01. Specific Areas of the part that have critical functions might be identified to
have a specific Quality Grade to meet in terms of discontinuity. Taiga engineers will define the grade to
meet based on the type of load and other functional requirements.
Function Class 1 Function Class 2 Function Class 3
Die Cast: Grade as per Grade A or Grade B Grade B or Grade C Grade C or Grade D
ASTM E505 references
Gravity Cast: Grade as Grade A or Grade B Grade B or Grade C Grade C or Grade D
per ASTM E155
references
Table 01: Applicable Quality Grade based on the Function Class of the part
The Supplier is responsible for obtaining the latest revision of the applicable ASTM Reference Radiographs.
As mentioned above, ASTM E155 is needed for gravity cast parts and ASTM E505 for die cast parts. The
supplier must evaluate a minimum of 5 samples per cavity during the PPAP phase. The level of inspection
during production is to be agreed on with TAIGA.
TAIGA MOTORS INC.
ALUMINUM CASTING SPECIFICATION Page 3 / 7
Rév. 01
Discontinuity – Level Requirements for die cast in Accordance with Reference Radiographs ASTM E505
Grade A Grade B Grade C Grade D
Discontinuity Wall thickness (mm)
≤9.5 >9.5 ≤9.5 >9.5 ≤9.5 >9.5 ≤9.5 >9.5
Porosity 1 1 2 2 3 3 4 4
Cold fill 1 NA 2 NA 3 NA 4 NA
Shrinkage 1 1 2 2 3 3 4 4
Foreign material 1 1 1 1 1 1 1 1
Table 02: Acceptance limits for Internal Defects in die cast parts according to ASTM E505
Discontinuity – Level Requirements for gravity cast in Accordance with Reference Radiographs ASTM E155
Grade A Grade B Grade C Grade D
Discontinuity Casting Wall thickness (mm)
≤12.5 >12.5 ≤12.5 >12.5 ≤12.5 >12.5 ≤12.5 >12.5
Gas holes None None 1 1 2 2 5 5
Gas porosity None None 1 1 3 3 7 7
(round)
Gas Porosity None None 1 1 3 4 5 5
(elongated)
Shrinkage cavity None None 1 1 2 2 3 3
Shrinkage None None 1 1 2 2 4 3
porosity or
sponge
Foreign material None None 1 1 2 2 4 4
(less dense)
Foreign material None None 1 1 2 1 4 3
(more dense)
Table 03: Acceptance limits for Internal Defects in gravity cast parts according to ASTM E155
Furthermore, the following defects are inadmissible for both die casting and gravity casting processes:
i. Pore chains
ii. Segregation
iii. Stuck welded joints
iv. Overlaps
v. Thermal and stress cracks
The following defects must not exceed drawing tolerance defined on the 2D drawing.
vi. Core and shape offset
vii. Irregular surfaces
Unless otherwise specified on the 2D drawing, Ejector pin marks formed when movable pins eject the
castings from the mold are to be within the tolerances defined in AA-CS-E9 (See Table 4 herein) and must
not interfere with assembly.
TAIGA MOTORS INC.
ALUMINUM CASTING SPECIFICATION Page 4 / 7
Rév. 01
Table 4: Ejector Pin marks tolerances
E. CAST SURFACE SMOOTHNESS SPECIFICATION BASED ON AA-CS-E18
The specification of external surface finish is required for aesthetic and functional cast parts. The AA-CS-
E18 provides guidelines for the typical surface smoothness that should be designed on the 2D drawing.
This guideline is to be used for final surface finish quality requirements for gravity or die-cast parts. The
value of the number is maximum as specified and indicates the maximum permissible sustained height
rating. Any lesser rating is acceptable. These maximum values are presented in Table 5.
Units High Medium Low
Microinches 300 420 560
Microns 7.5 11 14
Table 5: Surface Roughness guide
F. MATERIAL COMPOSITION AND MECHANICAL PROPERTIES
Unless otherwise specified, material characteristics must be validated against the industry standard
designated on the 2D drawing (e.g. ASTM B108, ASTM B179, etc.). All the mechanical and chemical
composition requirements communicated in section F below apply unless otherwise specified on the 2D
drawing.
F.1 Sampling
An inspection lot shall consist of an identifiable quantity of material of the same mill form, alloy, temper,
and nominal dimensions traceable to a heat-treat lot or lots (only applicable for heat treated material)
and subjected to inspection at one time. For each delivery, chemical composition and mechanical
properties compliance must be demonstrated as defined below.
F.2 Chemical composition
The product shall conform to the chemical composition limits prescribed by the 2D drawing. Conformance
shall be determined by the producer by taking samples at the time castings are poured in accordance with
Practice ASTM E716 and analyzed in accordance with Test Method ASTM E34, ASTM E607, or ASTM E1251.
F.3 Mechanical Properties
Samples for mechanical properties shall have the relevant testing Geometry of test specimens and the
location in the product from which they are taken shall be as specified in Test Method ASTM B 557. When
TAIGA MOTORS INC.
ALUMINUM CASTING SPECIFICATION Page 5 / 7
Rév. 01
agreed upon with the supplier dog bone specimens can also be included in tool design. All samples for
tension testing must be taken after any required heat treatments are performed. For ease of processing,
samples for tension testing may be taken from castings before any machining or surface finishing/coating.
A tension test is to be performed based on the ASTM B557 or equivalent Method. The material tensile
properties (tensile strength, yield strength and elongation) shall conform to the limits defined in the Table
of the relevant ASTM Standard or industry standard defined on the 2D drawing.
G. PART IDENTIFICATION AND TRACEABILITY
Any casting delivered to TAIGA must be properly and permanently identified using one of the following
methods: direct mold marking, laser marking or inkjet marking. Unless otherwise specified, the
identification is to contain the following information: Part Number, Revision, Cavity number and Material.
The location of this information is to be indicated on the 2D drawing.
In order to ensure traceability, a date wheel insert containing the month and year of production must be
included in the tool design.
H. REFRENCES
1. ASTM B108-19: Standard Specification for Aluminum-Alloy Permanent Mold Castings
2. ASTM E505-20: Standard Reference Radiographs for Inspection of Aluminum and Magnesium Die Castings
3. ASTM E155-20: Standard Reference Radiographs for Inspection of Aluminum and Magnesium Castings
4. ASTM E94-17: Standard Guide for Radiographic Examination Using Industrial Radiographic Film
5. AA-CS (Aluminum association standard)
6. ASTM B179-18: Standard Specification for Aluminum Alloys in Ingot and Molten Forms for Castings from All Casting
Processes
7. ASTM E716-16: Standard Practices for Sampling and Sample Preparation of Aluminum and Aluminum Alloys for
Determination of Chemical Composition by Spark Atomic Emission Spectrometry
8. ASTM E34-94: Standard Test Methods for Chemical Analysis of Aluminum and Aluminum-Base Alloys
9. ASTM E607-90: Standard Test Method for Optical Emission Spectrometric Analysis of Aluminum and Aluminum Alloys
by the Point-to-Plane Technique, Nitrogen Atmosphere
10. ASTM E1251-17a: Standard Test Method for Analysis of Aluminum and Aluminum Alloys by Spark Atomic Emission
Spectrometry
11. ASTM B557-15: Standard Test Methods for Tension Testing Wrought and Cast Aluminum- and Magnesium-Alloy
Products
I. REVISION HISTORY
REVISION DATE CHANGES/NOTES/COMMENTS SIGNED BY
2024-03-26 Major review. Sections B to J were rewritten. David Maltais
TAIGA MOTORS INC.
ALUMINUM CASTING SPECIFICATION Page 6 / 7
Rév. 01
J. ANNEX A
Image Quality Indicator (IQI)
Image Quality Indicators (IQIs) are devices placed within a radiographic set-up to indicate that a certain
contrast sensitivity and definition has been achieved. The quality level usually required for radiography is
2 % (2-2T when using hole type IQI) unless a higher or lower quality is agreed upon. Radiographic quality
level is usually expressed in percent of part thickness and diameter of feature to be detected. If a single
percent number is given, the feature diameter is assumed to be twice the given percent thickness of the
part. For example, if 2% is given for 1 in. thick part, the feature diameter is 2 × 0.02 × 1 in., which is 0.04
in.
IQI references
Examples of ASTM E505 and ASTM E155
The following images show typical Reference radiographs for informational purpose only. The Supplier is
responsible for obtaining the latest revision of the applicable ASTM Reference Radiographs. As mentioned
above ASTM E155 is needed for gravity cast parts and ASTM E505 for die cast parts.
TAIGA MOTORS INC.
ALUMINUM CASTING SPECIFICATION Page 7 / 7
Rév. 01
[READING ORDER TEXT]
TAIGA MOTORS INC.
Page 1 / 7
Rév. 01
ALUMINUM CASTING SPECIFICATION
A. SCOPE AND DESCRIPTION
This specification has the objective to define the level of acceptance for external and internal
discontinuities, surface roughness and other common casting defects. This specification also defines the
different standards that the productsmustmeet from a chemical composition and mechanical properties
standpoint. This document is applicable to any machined or unmachined aluminum part obtained from
thegravityorthediecastingprocess.Thesupplierisexpectedtoobtainthelatestrevisionofanystandard
referenced herein. This specification supersedes any previous casting specification produced by TAIGA.
B. FUNCTIONNAL CLASSIFICATION
The level of quality required will be defined based on the function class of the part which goes as follow:
• Function class 1: Castings with safety requirements.
• Functionclass2:Castingsstaticallyanddynamicallyloadedand/orsurfaceswithspecialfunctional
requirements.
• Function class 3: Castings not included in classes 1 or 2 without specific functional requirements.
The Function class will define the Quality level applicable for discontinuities. There are two general types
of discontinuities that occur during the casting process. They are:
i. Internal Defects
ii. External defects
C. EXTERNAL DEFECTS
Machined and unmachined faces must offer a homogenous appearance and must be free of cracks or
other faults which could impair the fit/function of the component and/or subsequent machining
operations. Coupons, flash, burrs, material residues, fractures, cracks, signs of overheating and scorches,
creases, cavities, depressions and cold shots which restrict the fit/function are inadmissible. They must
be eliminated by suitable measures taken by the supplier.
Any cast part supplied to TAIGA must fall within the acceptable limits as defined below, unless otherwise
specified on 2D drawing:
Function Class 1:
1. Reference area 100 mm2
(square shaped)
2. Number of pores per Reference area ≤ 10
3. Maximum 8 pores up to Ø 0.1 mm
4. Maximum 2 pores up to Ø 0.2 mm
Function Class 2:
1. Reference area 100 mm2
(square shaped)
2. Number of pores per Reference area ≤ 15
3. Maximum 12 pores up to Ø 0.3 mm
4. Maximum 3 pores up to Ø 0.5 mmTAIGA MOTORS INC.
Page 2 / 7
Rév. 01
ALUMINUM CASTING SPECIFICATION
Function Class 3:
1. Reference area 100 mm2
(square shaped)
2. Number of pores per Reference area ≤ 20
3. Maximum 14 pores up to Ø 0.5 mm
4. Maximum 6 pores up to Ø 1.0 mm
For all of the 3 Function Class no surface faults are permitted within an area equal to twice the diameter
of a threaded hole. Furthermore, through porosities (i.e. porosities open to two surfaces) are
unacceptable for any casting supplied to TAIGA. Blind porosities (i.e. porosities open to one surface)
exceeding the requirements of Section C are also unacceptable. Any leak tightness requirement will be
specified on the 2D drawing.
D. INTERNAL DEFECTS
Radiographic inspectionofInternal defects/discontinuitiesmust beperformed asper ASTM E94 Standard
GuideforRadiographicExaminationUsingIndustrialRadiographicFilm.IQI(ImageQualityIndicator)must
be present on all Radiographs produced by the supplier to testify to the level of detail and validate the
quality of the radiographs. Unless otherwise specified the minimum IQI level is 2%. See Annex A for more
information.
TheacceptancecriteriadevelopedbyTaiga(QualityGrades)arebasedontheReferenceRadiographsfrom
the following standards. Areas to be inspected shall be identified on the 2D drawings.
• Fordiecastparts:ASTME505-22StandardReferenceRadiographsforInspectionofAluminumand
Magnesium Die Castings. The different discontinuity levels are ranked on a scale of 1 to 4.
• Forgravitycastparts: ASTME155-20StandardReferenceRadiographsforInspectionofAluminum
and Magnesium Castings. The different discontinuity levels are ranked on a scale of 1 to 8.
Taiga 2D drawings will typically define the Function Class Level and the Quality Grade required on the
entire part based on Table 01. Specific Areas of the part that have critical functions might be identified to
have a specific Quality Grade to meet in terms of discontinuity. Taiga engineers will define the grade to
meet based on the type of load and other functional requirements.
Function Class 1 Function Class 2 Function Class 3
Die Cast: Grade as per
ASTM E505 references
Grade A or Grade B Grade B or Grade C Grade C or Grade D
Gravity Cast: Grade as
per ASTM E155
references
Grade A or Grade B Grade B or Grade C Grade C or Grade D
Table 01: Applicable Quality Grade based on the Function Class of the part
TheSupplierisresponsibleforobtainingthelatestrevisionoftheapplicableASTMReferenceRadiographs.
As mentioned above, ASTM E155 is needed for gravity cast parts and ASTM E505 for die cast parts. The
supplier must evaluate a minimum of 5 samples per cavity during the PPAP phase. The level of inspection
during production is to be agreed on with TAIGA.TAIGA MOTORS INC.
Page 3 / 7
Rév. 01
ALUMINUM CASTING SPECIFICATION
Discontinuity – Level Requirements for die cast in Accordance with Reference Radiographs ASTM E505
Discontinuity
Grade A Grade B Grade C Grade D
Wall thickness (mm)
≤9.5 >9.5 ≤9.5 >9.5 ≤9.5 >9.5 ≤9.5 >9.5
Porosity 1 1 2 2 3 3 4 4
Cold fill 1 NA 2 NA 3 NA 4 NA
Shrinkage 1 1 2 2 3 3 4 4
Foreign material 1 1 1 1 1 1 1 1
Table 02: Acceptance limits for Internal Defects in die cast parts according to ASTM E505
Table 03: Acceptance limits for Internal Defects in gravity cast parts according to ASTM E155
Furthermore, the following defects are inadmissible for both die casting and gravity casting processes:
i. Pore chains
ii. Segregation
iii. Stuck welded joints
iv. Overlaps
v. Thermal and stress cracks
The following defects must not exceed drawing tolerance defined on the 2D drawing.
vi. Core and shape offset
vii. Irregular surfaces
Unless otherwise specified on the 2D drawing, Ejector pin marks formed when movable pins eject the
castings from the mold are to be within the tolerances defined in AA-CS-E9 (See Table 4 herein) and must
not interfere with assembly.
Discontinuity – Level Requirements for gravity cast in Accordance with Reference Radiographs ASTM E155
Discontinuity
Grade A Grade B Grade C Grade D
Casting Wall thickness (mm)
≤12.5 >12.5 ≤12.5 >12.5 ≤12.5 >12.5 ≤12.5 >12.5
Gas holes None None 1 1 2 2 5 5
Gas porosity
(round)
None None 1 1 3 3 7 7
Gas Porosity
(elongated)
None None 1 1 3 4 5 5
Shrinkage cavity None None 1 1 2 2 3 3
Shrinkage
porosity or
sponge
None None 1 1 2 2 4 3
Foreign material
(less dense)
None None 1 1 2 2 4 4
Foreign material
(more dense)
None None 1 1 2 1 4 3TAIGA MOTORS INC.
Page 4 / 7
Rév. 01
ALUMINUM CASTING SPECIFICATION
Table 4: Ejector Pin marks tolerances
E. CAST SURFACE SMOOTHNESS SPECIFICATION BASED ON AA-CS-E18
The specification of external surface finish is required for aesthetic and functional cast parts. The AA-CS-
E18 provides guidelines for the typical surface smoothness that should be designed on the 2D drawing.
This guideline is to be used for final surface finish quality requirements for gravity or die-cast parts. The
value of the number is maximum as specified and indicates the maximum permissible sustained height
rating. Any lesser rating is acceptable. These maximum values are presented in Table 5.
Units High Medium Low
Microinches 300 420 560
Microns 7.5 11 14
Table 5: Surface Roughness guide
F. MATERIAL COMPOSITION AND MECHANICAL PROPERTIES
Unless otherwise specified, material characteristics must be validated against the industry standard
designated on the 2D drawing (e.g. ASTM B108, ASTM B179, etc.). All the mechanical and chemical
composition requirements communicated in section F below apply unless otherwise specified on the 2D
drawing.
F.1 Sampling
An inspection lot shall consist of an identifiable quantity of material of the same mill form, alloy, temper,
and nominal dimensions traceable to a heat-treat lot or lots (only applicable for heat treated material)
and subjected to inspection at one time. For each delivery, chemical composition and mechanical
properties compliance must be demonstrated as defined below.
F.2 Chemical composition
Theproductshallconformtothechemicalcompositionlimitsprescribedbythe2Ddrawing.Conformance
shallbedeterminedbytheproducerbytakingsamplesatthetimecastingsarepouredinaccordancewith
PracticeASTME716andanalyzedinaccordancewithTestMethodASTME34,ASTME607,orASTME1251.
F.3 Mechanical Properties
Samples for mechanical properties shall have the relevant testing Geometry of test specimens and the
location in the product from which they aretaken shall be as specified inTestMethod ASTM B557. WhenTAIGA MOTORS INC.
Page 5 / 7
Rév. 01
ALUMINUM CASTING SPECIFICATION
agreed upon with the supplier dog bone specimens can also be included in tool design. All samples for
tension testing must be taken after any required heat treatments are performed. For ease of processing,
samplesfortensiontestingmaybetakenfromcastingsbefore anymachiningorsurfacefinishing/coating.
A tension test is to be performed based on the ASTM B557 or equivalent Method. The material tensile
properties(tensilestrength,yieldstrengthandelongation)shallconformtothelimitsdefinedintheTable
of the relevant ASTM Standard or industry standard defined on the 2D drawing.
G. PART IDENTIFICATION AND TRACEABILITY
Any casting delivered to TAIGA must be properly and permanently identified using one of the following
methods: direct mold marking, laser marking or inkjet marking. Unless otherwise specified, the
identificationistocontainthefollowinginformation:PartNumber,Revision,Cavitynumber andMaterial.
The location of this information is to be indicated on the 2D drawing.
In order to ensure traceability, a date wheel insert containing the month and year of production must be
included in the tool design.
H. REFRENCES
1. ASTM B108-19: Standard Specification for Aluminum-Alloy Permanent Mold Castings
2. ASTM E505-20: Standard Reference Radiographs for Inspection of Aluminum and Magnesium Die Castings
3. ASTM E155-20: Standard Reference Radiographs for Inspection of Aluminum and Magnesium Castings
4. ASTM E94-17: Standard Guide for Radiographic Examination Using Industrial Radiographic Film
5. AA-CS (Aluminum association standard)
6. ASTM B179-18: Standard Specification for Aluminum Alloys in Ingot and Molten Forms for Castings from All Casting
Processes
7. ASTM E716-16: Standard Practices for Sampling and Sample Preparation of Aluminum and Aluminum Alloys for
Determination of Chemical Composition by Spark Atomic Emission Spectrometry
8. ASTM E34-94: Standard Test Methods for Chemical Analysis of Aluminum and Aluminum-Base Alloys
9. ASTM E607-90: Standard Test Method for Optical Emission Spectrometric Analysis of Aluminum and Aluminum Alloys
by the Point-to-Plane Technique, Nitrogen Atmosphere
10. ASTM E1251-17a: Standard Test Method for Analysis of Aluminum and Aluminum Alloys by Spark Atomic Emission
Spectrometry
11. ASTM B557-15: Standard Test Methods for Tension Testing Wrought and Cast Aluminum- and Magnesium-Alloy
Products
I. REVISION HISTORY
REVISION DATE CHANGES/NOTES/COMMENTS SIGNED BY
2024-03-26 Major review. Sections B to J were rewritten. David MaltaisTAIGA MOTORS INC.
Page 6 / 7
Rév. 01
ALUMINUM CASTING SPECIFICATION
J. ANNEX A
Image Quality Indicator (IQI)
Image Quality Indicators (IQIs) are devices placed within a radiographic set-up to indicate that a certain
contrast sensitivity and definition has been achieved. The quality level usually required for radiography is
2 % (2-2T when using hole type IQI) unless a higher or lower quality is agreed upon. Radiographic quality
level is usually expressed in percent of part thickness and diameter of feature to be detected. If a single
percent number is given, the feature diameter is assumed to be twice the given percent thickness of the
part. For example, if 2% is given for 1 in. thick part, the feature diameter is 2 × 0.02 × 1 in., which is 0.04
in.
Examples of ASTM E505 and ASTM E155
The following images show typical Reference radiographs for informational purpose only. The Supplier is
responsibleforobtainingthelatestrevisionoftheapplicableASTMReferenceRadiographs.Asmentioned
above ASTM E155 is needed for gravity cast parts and ASTM E505 for die cast parts.
IQI referencesTAIGA MOTORS INC.
Page 7 / 7
Rév. 01
ALUMINUM CASTING SPECIFICATION
[OCR SUPPLEMENT; page rendered and visually reviewed]
[PDF page 4]
TAIGA MOTORS INC.
A TAIBGA ALUMINUM CASTING SPECIFICATION Page 4/7
Projected Area Tolerance
in.? cm? in. mm
Upthru 50 320 + 0.020 +0.50
Over 50 thru 100 320 thru 650 + 0.030 +0.80
Over 100 thru 200 650 thru 1300 + 0.045 +1.10
Over 200 1300 CONSULT FOUNDRY
Table 4: Ejector Pin marks tolerances
E. CAST SURFACE SMOOTHNESS SPECIFICATION BASED ON AA-CS-E18
The specification of external surface finish is required for aesthetic and functional cast parts. The AA-CS-
E18 provides guidelines for the typical surface smoothness that should be designed on the 2D drawing.
This guideline is to be used for final surface finish quality requirements for gravity or die-cast parts. The
value of the number is maximum as specified and indicates the maximum permissible sustained height
rating. Any lesser rating is acceptable. These maximum values are presented in Table 5.
Units High Medium Low
Microinches 300 420 560
Microns 7.5 11 14
Table 5: Surface Roughness guide
F. MATERIAL COMPOSITION AND MECHANICAL PROPERTIES
Unless otherwise specified, material characteristics must be validated against the industry standard
designated on the 2D drawing (e.g. ASTM B108, ASTM B179, etc.). All the mechanical and chemical
composition requirements communicated in section F below apply unless otherwise specified on the 2D
drawing.
F.1 Sampling
An inspection lot shall consist of an identifiable quantity of material of the same mill form, alloy, temper,
and nominal dimensions traceable to a heat-treat lot or lots (only applicable for heat treated material)
and subjected to inspection at one time. For each delivery, chemical composition and mechanical
properties compliance must be demonstrated as defined below.
F.2 Chemical composition
The product shall conform to the chemical composition limits prescribed by the 2D drawing. Conformance
shall be determined by the producer by taking samples at the time castings are poured in accordance with
Practice ASTM E716 and analyzed in accordance with Test Method ASTM E34, ASTM E607, or ASTM E1251.
F.3 Mechanical Properties
Samples for mechanical properties shall have the relevant testing Geometry of test specimens and the
location in the product from which they are taken shall be as specified in Test Method ASTM B 557. When
[PDF page 6]
TAIGA MOTORS INC.
A TAIGA ALUMINUM CASTING SPECIFICATION Page 6/7
Rév. 01
J. ANNEX A
Image Quality Indicator (IQ)
Image Quality Indicators (IQIs) are devices placed within a radiographic set-up to indicate that a certain
contrast sensitivity and definition has been achieved. The quality level usually required for radiography is
2 % (2-2T when using hole type IQI) unless a higher or lower quality is agreed upon. Radiographic quality
level is usually expressed in percent of part thickness and diameter of feature to be detected. If a single
percent number is given, the feature diameter is assumed to be twice the given percent thickness of the
part. For example, if 2% is given for 1 in. thick part, the feature diameter is 2 x 0.02 x 1 in., which is 0.04
in.
Examples of ASTM E505 and ASTM E155
The following images show typical Reference radiographs for informational purpose only. The Supplier is
responsible for obtaining the latest revision of the applicable ASTM Reference Radiographs. As mentioned
above ASTM E155 is needed for gravity cast parts and ASTM E505 for die cast parts.
[PDF page 7]
TAIGA MOTORS INC.
A TAIGA ALUMINUM CASTING SPECIFICATION Page 7/7
Rév. 01
[Visual transcription PDFp4 Table4 Ejector Pin marks tolerances; projected area in²/cm² => tolerance inches/mm]
Up through50in²/320cm² => ±0.020in/±0.50mm
Over50through100in²/320through650cm² => ±0.030in/±0.80mm
Over100through200in²/650through1300cm² => ±0.045in/±1.10mm
Over200in²/1300cm² => Consult foundry
[Visual figure review PDFpp6-7: examples of ASTM E505 die-cast porosity/coldfill/shrinkage radiographs and ASTM E155 shrinkage sponge reference radiographs. These are generic example standards, not Taiga measured component results.]Identifikace uložené verze
SHA-256: bd9435f449ac7e16345b643b3bfdc7499b4518a26159844d9fd4549cafa86a38