Free Shipping on All Motors & Controllers — Now Available Across the U.S. ✕ Browse Shopping Portal All Markets Air Support ATV | Utility Vehicle | Hunting Buggy Automated Guided Vehicle Systems (AGVS) Boom Lift & Scissor Lift Autohauler Pump Motors Boats Bow and Stern Thruster Electric Vehicle | EV Farm Tractor Floor Care Golf Carts Go Karts Hydraulic Pump Lawn Mower Material handling Mining Motorcycles NEV Party & Beer Bike | Railcar Warning Siren Wind Turbine View All Product Line Current Motor Range Current Contoller Range Choose A Motor / Controller Golf Cart Motors Golf Cart Controllers Hydraulic Pump Motors Solenoids | Fuses | Resistors | Diodes Golf Cart Wire Kits Electric Vehicle Conversions Motor Parts Plastic Spools Quote Request Drive Motor Quote Pump Motor Quote Replacement Motor Quote Downloads Golf Cart Manuals Warranty Policy Terms and Conditions FAQs Tech Tips Installation Videos Photo Gallery Beginners Guide to Motors DC vs AC Golf Carts About Us Dealer Portal Login Dealer Application D&D Motor Systems, Inc (315) 701-0635 Add to Cart? Warranty Terms Only provided if used on stock factory vehicle with NO non-standard parts. Liability Disclaimer * Agreement Required * I agree, it is my responsisbility to ensure this product will work with regards to form, fit and function for my specific design and application. D&D Motor Systems, Inc assumes NO liabilities otherwise. View the motor outline print and performance charts on the previous page.View the controller dimensions and spec sheet on the previous page.View the solenoid spec sheet on the previous page. Go Back All Markets Browse All Markets Select your application Air Support ATV | Utility Vehicle Automated Guided Vehicle Boom & Scissor Lift Autohauler Pumps Boats Bow & Stern Thruster Electric Vehicles Farm Tractor Floor Care Golf Carts Go Karts Hydraulic Pump Lawn Mower Material Handling Mining Motorcycles NEV Party & Beer Bike Warning Siren Wind Turbine View All Markets Browse Shopping Portal Product Line Choose A Motor / Controller Current Motor Range Current Contoller Range Electric Vehicle Conversions Golf Cart Motors Golf Cart Controllers Golf Cart Wire Kits Hydraulic Pump Motors Motor Parts Plastic Spools Solenoids | Fuses | Resistors | Diodes Quote Request Drive Motor Quote Pump Motor Quote Replacement Motor Quote Downloads Golf Cart Manuals Warranty Policy Motor RMA Form Controller RMA Form Terms and Conditions FAQ Tech Tips Installation Videos Photo Gallery Beginners Guide to Motors DC vs AC Golf Carts About Us Dealer Dealer Portal Login Dealer Application Neighborhood Electric Vehicles | GEM Motors D&D Motor Systems is the premier manufacturer of electric DC neighborhood electric vehicle motors in the U.S.. We specialize in NEV motors for almost all NEV vehicles too include GEM Car motor parts, Ford Think, Columbia Par Car, Polaris Breeze, and many others. Our high-performance NEV motors offer superior torque, enhanced thermal capabilities, and a competitive price, all while being proudly made in the USA. Whether you're looking for a DC or AC motor for your NEV vehicle application, we have you covered. We also offer a complete line of U.S. made electric DC and AC NEV controllers. We have more than 100 years of Key Management experience in electric DC NEV motor design and manufacturing. Global Electric Motorcar Motors (GEM Motors) Performance Focus D&D Part Number Speed (mph) Stock 170-501-0002B 25-27 BUY NOW $919 Use this 72V GEM Car Motor for 2 or 4 passenger GEM cars being used in a flat or rolling hill environments only. Use this ventilated GEM Car Motor on clean road or non-salt water environments ONLY !! Speed 170-504-0001D 28-30 BUY NOW $979 Torque 170-514-0001A 21-23 BUY NOW $1,029 Torque and Speed 170-520-0001A 26-28 BUY NOW $1,029 Series VS Regen Differences GEM Car Motor Features Easy to install 72V replacement GEM Car Motors with no controller programming. GEM Car motors Made In The USA with American GEM Car Parts. Our GEM Car motors use more Copper and Steel, which reduces current draw, extends range and increases the thermal capabilities of the GEM Car Motors. If you require controller programming, contact one of our dealer experts listed below under the "Experts" tab for GEM Car Motors. Columbia Par Car Motors D&D Part Number 170-501-0001C BUY NOW $949 Replaces Cross Reference Numbers: 170-501-0001B, 170-501-0002E, 193186U, 69300-03, 719135, Columbia Par Car Electric Motor, CP100402, CVG193186U, CVG719135, MO271U 170-504-0001B BUY NOW $1,029 Replaces Cross Reference Numbers: 170-504-0001, 3268, 5BC49JB1162, 69301-04, 7115, 7139, 719339, 759929, CP100403, CVG193187U, CVG719339, EX0-4003, EX1-4006, EY7-4001, GG6-4003, MT11-330, ZQ48 3.0 B-T, ZQ48-3.0B-T, ZQ48.3.0B-T 170-501-0004 BUY NOW $929 Replaces Cross Reference Numbers: 170-501-0004, 2450003, 69304-04, 719370, Columbia Par Car Electric Motor, CP100404, CVG719370, DD0-4002 Ford Think Electric Motors D&D Part Number 170-515-0003 BUY NOW $879 Replaces Cross Reference Numbers: 104874420, 2E38-14B280-BA, EA2-4001 Polaris Breeze Motors D&D Part Number 170-501-0002F BUY NOW $1,049 Replaces Cross Reference Numbers: 170-501-0001D, 2411618 Need a Custom NEV Motor? Drive Motor Quote EV Motor Quick Links Photos Videos Experts Photo Gallery X Basic GEM Motor & Controller Installation Instructions Along with these written instructions we also provide instructional videos to assist with installation at our Videos Tab above under our "EV Motor Quicklinks" header. Installation of your new motor is a 3-part process First you have to take the existing motor out. Step two is the actual motor installation, which includes making sure the new motor is functioning correctly. This is important because if there are any unknown issues we want to be able to isolate them prior to introducing any controller reprogramming. The last potential step is the controller reprogramming which will happen once the motor is installed and running correctly. This is completely dependent on what the end customer is looking for with regards to performance. D&D Motor Systems relies on its over 2000 golf and Gem car dealers and distributors worldwide to assist all customers with that reprogramming service if required. Step 1 – Uninstall Existing Motor Turn off main power switch. On pre 2005 models the switch is located under the seat, while on newer models it is located under the dashboard. On 2005 and newer models you should remove one of any of the battery cables. Failure to disconnect the batteries may result in damaging the controller. Removing the front tire makes it easier to access the old motor and install the new one. From the passenger side, disconnect the speedometer by opening the male/female 3 pin connector. This procedure can be viewed in the NEV videos section from the D&D Motor Systems online installation page at our Videos Tab. From the passenger side, on 2003 or later models, disconnect the overheat sensor which is flat 2-pin plug. This procedure can also be viewed in the NEV videos section from the D&D Motor Systems online installation page at our Videos Tab. From the passenger side, remove all electrical connections from the old motor. We suggest taking a quick photo of what all your connections looked like before you start disconnecting, just in case you may want to reference later. The connections you will be disconnecting will include the two to the commutator end head (grey colored casting) and the two to the frame & field, which are the ones coming out of the Blue housing. From the driver’s side of the car, remove the 3 bolts (7/16”) that hold the motor to the trans-axel. Be sure to take notice of the position of the terminals, as the new motor will need to be installed in the similar position. Slide the motor back approximately an inch and it can be removed from the vehicle - Use caution, as the motor is heavy and can cause injury if not handle with care. The standard 11 HP motor weighs 48 lbs and the motor part #’s which start with ES are even more! Step 2 – Motor Installation With old motor now out of the vehicle, go ahead and remove the black rubber bushing, which is located at the bottom of the female splined shaft. Apply Loctite to the 3 motor bolts which are used to mount the motor thru the transaxle and let it cure for 10 minutes. Seat the bushing that was removed from old motor into the same location on the new motor. Line-up the motor and position it the same as before on the transaxle. Once again, the motor should be positioned so the terminals are in a similar position as the old motor was. The body of the motor can be twisted from left to right to allow for alignment with the mounting holes. Install the 3 bolts that attach the motor to the transaxle. When installing the bolts you only need a snug wrist tightening. The Loctite will harden and provide a secure fit. Review the picture you took of your wire connections prior to uninstalling the old motor and reconnect the wire connections all the same way. BEWARE - do not over tighten the 4 brass posts otherwise the field wire connections on the inside can break. On 2004 and older GEM cars, reconnect the 3 wire speedometer connector and continue to step 8. On 2005 and newer; the speedometer magnet needs to be changed. This is accomplished by taking out the 2 #10 torque screws on the side of the speed sensor cap. This will remove the small black cap that the speedometer wires are attached to. Once the cap is off there will be a circular magnet held in by a 4 mm allen bolt. The magnet is about an inch in diameter and is a black/dark brown in color. In your motor package, you will have a white envelope, which contains the required replacement magnet. Simply remove the 4 MM allen bolt in the center of the circular magnet and switch the magnet with the new one provided. There is no in or out side to the magnet, there also is no difference in the appearance between the 2 magnets so be sure they don’t get confused. Apply a drop or two of Loctite to the allen bolt and install the new magnet hand tight. This procedure can also be viewed in the NEV videos section from the D&D Motor Systems online installation page at our Videos Tab. Important note - on the original motor there was a wire holder holding the 3 wires and connector tight to the side of the motor. The reason it is there is to hold the wire close to the motor and avoid it being hit by the tire. This wire holder must be put back onto the new motor. If it was missing you can just pull the wires tight on the side and use a zip tie on the top of the motor attaching them to anything solid. On 2003 and newer models, the 2-pin plug will need to be “shorted out”. The overheat sensor is no longer required with the use of the D&D Motor Systems motors. This can be done by using a jumper wire between the two wires or simply cutting off the plug and connecting the 2 wires together and taping them. Do not short the wires out to the frame of the car as it can cause controller damage. Failure to jump the wires on 2003 or newer models will cause the vehicle to operate in slow mode only. Lastly, you should reinstall the tires, turn on battery switch and reconnect any disconnected battery cable. At this point and time you are ready to run your GEM car. It should run as strong as or stronger than it did before without doing anything to the controller. If you are happy with the performance then you are all done. If you are looking for a different overall performance out of your GEM car then it’s time to move on to the third step – controller reprogramming. Since D&D Motor Systems, Inc. has thousands of golf and GEM car distributors and dealers around the world, we will direct you to the closest ones to your location We want you to be 100% satisfied so if after working with one of our dealers and distributors, you are not happy with your performance, be sure to contact D&D Motor Systems, Inc.. Step 3 – Controller Reprogramming (if required) If the customer is not equipped, willing or able to handle the controller un-installation or installation process, then we will search for a source from our extensive golf and GEM car network over 2000 strong worldwide to help you out. Often a quick video can be much more helpful than written installation instructions. There are many additional videos out on the internet which help with regards to un-installing and reinstalling the controllers from GEM cars. Several of these videos can also be viewed in the NEV videos section from the D&D Motor Systems online installation page at our Videos Tab. Just look for the heading of what you are interested in learning. They are often listed in chronological order. Before going to that link, please complete reading the entire installation manual below. BEWARE – Do not be fooled by middleman sources which do not offer a complete line of GEM car motors to handle the many different customer GEM car setups, applications, and performance requirements. Also, there are many Black & Grey motors which are made in China & Mexico. ONLY the BLUE motor is the one which has thousands in the field all over the world since 2001 and is completely US Made There are 2 different controllers used in GEM cars. Therefore, there are 2 different sets of removal & installation video instructions. The one controller is for models that are 2005 and newer (Figure A below) and the other for versions that are for models that are 2004 and older (Figure B below). If you have any questions and are not getting the response you would like, let us know and we will be sure to find you the right help. Why is my GEM Car Going so Slow? Possible answer is, on 2005-2015 models, the 2-pin plug will need to be “shorted out”. The over heat sensor is no longer required with the use of the D&D motors. This can be done by using a jumper wire between the two wires or simply cutting off the plug and connecting the 2 wires together and taping them. Do not short the wires out to the frame of the car as it can cause controller damage. Failure to jump the wires on 03’ or newer models will cause the vehicle to operate in slow mode only. This procedure can be viewed in the 7.5HP videos from the Ride-4-Fun online installation page at http://www.ride-4-fun.com/instructions. FAQ Tech Tips × Regen VS Series Series Motor The series motor provides high starting torque and is able to move very large shaft loads when it is first energized. Figure 12-10 shows the wiring diagram of a series motor. From the diagram you can see that the field winding in this motor is wired in series with the armature winding. This is the attribute that gives the series motor its name. Since the series field winding is connected in series with the armature, it will carry the same amount of current that passes through the armature. For this reason the field is made from heavy-gauge wire that is large enough to carry the load. Since the wire gauge is so large, the winding will have only a few turns of wire. In some larger DC motors, the field winding is made from copper bar stock rather than the conventional round wire used for power distribution. The square or rectangular shape of the copper bar stock makes it fit more easily around the field pole pieces. It can also radiate more easily the heat that has built up in the winding due to the large amount of current being carried. FIGURE 12-10 Electrical diagram of series motor. Notice that the series field is identified as S1 and S2. The amount of current that passes through the winding determines the amount of torque the motor shaft can produce. Since the series field is made of large conductors, it can carry large amounts of current and produce large torques. For example, the starter motor that is used to start an automobile's engine is a series motor and it may draw up to 500 A when it is turning the engine's crankshaft on a cold morning. Series motors used to power hoists or cranes may draw currents of thousands of amperes during operation. The series motor can safely handle large currents since the motor does not operate for an extended period. In most applications the motor will operate for only a few seconds while this large current is present. Think about how long the starter motor on the automobile must operate to get the engine to start. This period is similar to that of industrial series motors. Series Motor Operation Operation of the series motor is easy to understand. In Fig. 12-10 you can see that the field winding is connected in series with the armature winding. This means that power will be applied to one end of the series field winding and to one end of the armature winding (connected at the brush). When voltage is applied, current begins to flow from negative power supply terminals through the series winding and armature winding. The armature is not rotating when voltage is first applied, and the only resistance in this circuit will be provided by the large conductors used in the armature and field windings. Since these conductors are so large, they will have a small amount of resistance. This causes the motor to draw a large amount of current from the power supply. When the large current begins to flow through the field and armature windings, it causes a strong magnetic field to be built. Since the current is so large, it will cause the coils to reach saturation, which will produce the strongest magnetic field possible. Producing Back EMF The strength of these magnetic fields provides the armature shafts with the greatest amount of torque possible. The large torque causes the armature to begin to spin with the maximum amount of power. When the armature begins to rotate, it begins to produce voltage. This concept is difficult for some students to understand since the armature is part of the motor at this time. You should remember from the basic theories of magnetism that anytime a magnetic field passes a coil of wire, a current will be produced. The stronger the magnetic field is or the faster the coil passes the flux lines, the more current will be generated. When the armature begins to rotate, it will produce a voltage that is of opposite polarity to that of the power supply. This voltage is called back voltage, back EMF (electromotive force), or counter EMF. The overall effect of this voltage is that it will be subtracted from the supply voltage so that the motor windings will see a smaller voltage potential. When Ohm's law is applied to this circuit, you will see that when the voltage is slightly reduced, the current will also be reduced slightly. This means that the series motor will see less current as its speed is increased. The reduced current will mean that the motor will continue to lose torque as the motor speed increases. Since the load is moving when the armature begins to pick up speed, the application will require less torque to keep the load moving. This works to the motor's advantage by automatically reducing the motor current as soon as the load begins to move. It also allows the motor to operate with less heat buildup. This condition can cause problems if the series motor ever loses its load. The load could be lost when a shaft breaks or if a drive pin is sheared. When this occurs, the load current is allowed to fall to a minimum, which reduces the amount of back EMF that the armature is producing. Since the armature is not producing a sufficient amount of back EMF and the load is no longer causing a drag on the shaft, the armature will begin to rotate faster and faster. It will continue to increase rotational speed until it is operating at a very high speed. When the armature is operating at high speed, the heavy armature windings will be pulled out of their slots by centrifugal force. When the windings are pulled loose, they will catch on a field winding pole piece and the motor will be severely damaged. This condition is called runaway and you can see why a DC series motor must have some type of runaway protection. A centrifugal switch can be connected to the motor to de-energize the motor starter coil if the rpm exceeds the set amount. Other sensors can be used to de-energize the circuit if the motor's current drops while full voltage is applied to the motor. The most important part to remember about a series motor is that it is difficult to control its speed by external means because its rpm is determined by the size of its load. (In some smaller series motors, the speed can be controlled by placing a rheostat in series with the supply voltage to provide some amount of change in resistance to control the voltage to the motor.) Figure 12-11 shows the relationship between series motor speed and armature current. From this curve you can see that when current is low (at the top left), the motor speed is maximum, and when current increases, the motor speed slows down (bottom right). You can also see from this curve that a DC motor will run away if the load current is reduced to zero. (It should be noted that in larger series machines used in industry, the amount of friction losses will limit the highest speed somewhat.) FIGURE 12-11 The relationship between series motor speed and the armature current. Reversing the Rotation The direction of rotation of a series motor can be changed by changing the polarity of either the armature or field winding. It is important to remember that if you simply changed the polarity of the applied voltage, you would be changing the polarity of both field and armature windings and the motor's rotation would remain the same. FIGURE 12-12 DC series motor connected to forward and reverse motor starter. Since only one of the windings needs to be reversed, the armature winding is typically used because its terminals are readily accessible at the brush rigging. Remember that the armature receives its current through the brushes, so that if their polarity is changed, the armature's polarity will also be changed. A reversing motor starter is used to change wiring to cause the direction of the motor's rotation to change by changing the polarity of the armature windings. Figure 12-12 shows a DC series motor that is connected to a re-versing motor starter. In this diagram the armature's terminals are marked Al and A2 and the field terminals are marked Sl and S2. When the forward motor starter is energized, the top contact identified as F closes so the Al terminal is connected to the positive terminal of the power supply and the bottom F contact closes and connects terminals A2 and Sl. Terminal S2 is connected to the negative terminal of the power supply. When the reverse motor starter is energized, terminals Al and A2 are reversed. A2 is now connected to the positive terminal. Notice that S2 remains connected to the negative terminal of the power supply terminal. This ensures that only the armature's polarity has been changed and the motor will begin to rotate in the opposite direction. You will also notice the normally closed (NC) set of R contacts connected in series with the forward push button, and the NC set of F contacts connected in series with the reverse push button. These contacts provide an interlock that prevents the motor from being changed from forward to reverse direction without stopping the motor. The circuit can be explained as follows: when the forward push button is depressed, current will flow from the stop push button through the NC R interlock contacts, and through the forward push button to the forward motor starter (FMS) coil. When the FMS coil is energized, it will open its NC contacts that are connected in series with the reverse push button. This means that if someone depresses the reverse push button, current could not flow to the reverse motor starter (RMS) coil. If the person depressing the push buttons wants to reverse the direction of the rotation of the motor, he or she will need to depress the stop push button first to de-energize the FMS coil, which will allow the NC F contacts to return to their NC position. You can see that when the RMS coil is energized, its NC R contacts that are connected in series with the forward push button will open and prevent the current flow to the FMS coil if the forward push button is depressed. You will see a number of other ways to control the FMS and RMS starter in later discussions and in the chapter on motor controls. Installing and Troubleshooting Since a series motor has only two leads brought out of the motor for installation wiring, this wiring can be accomplished rather easily. If the motor is wired to operate in only one direction, the motor terminals can be connected to a manual or magnetic starter. If the motor's rotation is required to be reversed periodically, it should be connected to a reversing starter. Most DC series motors are used in direct-drive applications. This means that the load is connected directly to the armature's shaft. This type of load is generally used to get the most torque converted. Belt-drive applications are not recommended since a broken belt would allow the motor to run away. After the motor has been installed, a test run should be used to check it out. If any problems occur, the troubleshooting procedures should be used. The most likely problem that will occur with the series motor is that it will develop an open in one of its windings or between the brushes and the commutator. Since the coils in a series motor are connected in series, each coil must be functioning properly or the motor will not draw any current. When this occurs, the motor cannot build a magnetic field and the armature will not turn. Another problem that is likely to occur with the motor circuit is that circuit voltage will be lost due to a blown fuse or circuit breaker. The motor will respond similarly in both of these conditions. The best way to test a series motor is with a voltmeter. The first test should be for applied voltage at the motor terminals. Since the motor terminals are usually connected to a motor starter, the test leads can be placed on these terminals. If the meter shows that full voltage is applied, the problem will be in the motor. If it shows that no voltage is present, you should test the supply voltage and the control circuit to ensure that the motor starter is closed. If the motor starter has a visual indicator, be sure to check to see that the starter's contacts are closed. If the overloads have tripped, you can assume that they have sensed a problem with the motor or its load. When you reset the overloads, the motor will probably start again but remember to test the motor thoroughly for problems that would cause an overcurrent situation. If the voltage test indicates that the motor has full applied voltage to its terminals but the motor is not operating, you can assume that you have an open in one of the windings or between the brushes and the armature and continue testing. Each of these sections should be disconnected from each other and voltage should be removed so that they can be tested with an ohmmeter for an open. The series field coils can be tested by putting the ohmmeter leads on terminals Sl and S2. If the meter indicates that an open exists, the motor will need to be removed and sent to be rewound or replaced. If the meter indicates that the field coil has continuity, you should continue the procedure by testing the armature. The armature can also be tested with an ohmmeter by placing the leads on the terminals marked Al and A2. If the meter shows continuity, rotate the armature shaft slightly to look for bad spots where the commutator may have an open or the brushes may not be seated properly. If the armature test indicates that an open exists, you should continue the test by visually inspecting the brushes and commutator. You may also have an open in the armature coils. The armature must be removed from the motor frame to be tested further. When you have located the problem, you should remember that the commutator can be removed from the motor while the motor remains in place and it can be turned down on a lathe. When the commutator is replaced in the motor, new brushes can be installed and the motor will be ready for use. It is possible that the motor will develop a problem but still run. This type of problem usually involves the motor overheating or not being able to pull its rated load. This type of problem is different from an open circuit because the motor is drawing current and trying to run. Since the motor is drawing current, you must assume that there is not an open circuit. It is still possible to have brush problems that would require the brushes to be re-seated or replaced. Other conditions that will cause the motor to overheat include loose or damaged field and armature coils. The motor will also overheat if the armature shaft bearing is in need of lubrication or is damaged. The bearing will seize on the shaft and cause the motor to build up friction and overheat. If either of these conditions occurs, the motor may be fixed on site or be removed for extensive repairs. When the motor is restarted after repairs have been made, it is important to monitor the current usage and heat buildup. Remember that the motor will draw DC current so that an AC clamp-on ammeter will not be useful for measuring the DC current. You will need to use an ammeter that is specially designed for very large DC currents. It is also important to remember that the motor can draw very high locked-rotor current when it is starting, so the ammeter should be capable of measuring currents up to 1000 A. After the motor has completed its test run successfully, it can be put back into operation for normal duty. Anytime the motor is suspected of faulty operation, the troubleshooting procedure should be rechecked. DC Series Motor Used as a Universal Motor The series motor is used in a wide variety of power tools such as electric hand drills, saws, and power screwdrivers. In most of these cases, the power source for the motor is AC voltage. The DC series motor will operate on AC voltage. If the motor is used in a hand drill that needs variable-speed control, a field rheostat or other type of current control is used to control the speed of the motor. In some newer tools, the current control uses solid-state components to control the speed of the motor. You will notice that the motors used for these types of power tools have brushes and a commutator, and these are the main parts of the motor to wear out. You can use the same theory of operation provided for the DC motor to troubleshoot these types of motors. Shunt or Regen or SEPEX Motor The shunt motor is different from the series motor in that the field winding is connected in parallel with the armature instead of in series. You should remember from basic electrical theory that a parallel circuit is often referred to as a shunt. Since the field winding is placed in parallel with the armature, it is called a shunt winding and the motor is called a shunt motor. Figure 12-13 shows a diagram of a shunt motor. Notice that the field terminals are marked Fl and F2, and the armature terminals are marked Al andA2. You should notice in this diagram that the shunt field is represented with multiple turns using a thin line. FIGURE 12-13 Diagram of DC shunt motor. Notice the shunt coil is identified as a coil of fine wire with many turns that is connected in parallel (shunt) with the armature. FIGURE 12-14 Typical DC shunt motor. These motors are available in a variety of sizes. This motor is a 1 hp (approximately 8 in. tall). The shunt winding is made of small-gauge wire with many turns on the coil. Since the wire is so small, the coil can have thousands of turns and still fit in the slots. The small-gauge wire cannot handle as much current as the heavy-gauge wire in the series field, but since this coil has many more turns of wire, it can still produce a very strong magnetic field. Figure 12-14 shows a picture of a DC shunt motor. Shunt Motor Operation A shunt motor has slightly different operating characteristics than a series motor. Since the shunt field coil is made of fine wire, it cannot produce the large current for starting like the series field. This means that the shunt motor has very low starting torque, which requires that the shaft load be rather small. When voltage is applied to the motor, the high resistance of the shunt coil keeps the overall current flow low. The armature for the shunt motor is similar to the series motor and it will draw current to produce a magnetic field strong enough to cause the armature shaft and load to start turning. Like the series motor, when the armature begins to turn, it will produce back EMF. The back EMF will cause the current in the armature to begin to diminish to a very small level. The amount of current the armature will draw is directly related to the size of the load when the motor reaches full speed. Since the load is generally small, the armature current will be small. When the motor reaches full rpm, its speed will remain fairly constant. Controlling the Speed When the shunt motor reaches full rpm, its speed will remain fairly constant. The reason the speed remains constant is due to the load characteristics of the armature and shunt coil. You should remember that the speed of a series motor could not be controlled since it was totally dependent on the size of the load in comparison to the size of the motor. If the load was very large for the motor size, the speed of the armature would be very slow. If the load was light compared to the motor, the armature shaft speed would be much faster, and if no load was present on the shaft, the motor could run away. The shunt motor's speed can be controlled. The ability of the motor to maintain a set rpm at high speed when the load changes is due to the characteristic of the shunt field and armature. Since the armature begins to produce back EMF as soon as it starts to rotate, it will use the back EMF to maintain its rpm at high speed. If the load increases slightly and causes the armature shaft to slow down, less back EMF will be produced. This will allow the difference between the back EMF and applied voltage to become larger, which will cause more current to flow. The extra current provides the motor with the extra torque required to regain its rpm when this load is increased slightly. The shunt motor's speed can be varied in two different ways. These include varying the amount of current supplied to the shunt field and controlling the amount of current supplied to the armature. Controlling the current to the shunt field allows the rpm to be changed 10-20% when the motor is at full rpm. This type of speed control regulation is accomplished by slightly increasing or decreasing the voltage applied to the field. The armature continues to have full voltage applied to it while the current to the shunt field is regulated by a rheostat that is connected in series with the shunt field. When the shunt field's current is decreased, the motor's rpm will increase slightly. When the shunt field's current is reduced, the armature must rotate faster to produce the same amount of back EMF to keep the load turning. If the shunt field current is increased slightly, the armature can rotate at a slower rpm and maintain the amount of back EMF to produce the armature current to drive the load. The field current can be adjusted with a field rheostat or an SCR current control. The shunt motor's rpm can also be controlled by regulating the voltage that is applied to the motor armature. This means that if the motor is operated on less voltage than is shown on its data plate rating, it will run at less than full rpm. You must remember that the shunt motor's efficiency will drop off drastically when it is operated below its rated voltage. The motor will tend to overheat when it is operated below full voltage, so motor ventilation must be provided. You should also be aware that the motor's torque is reduced when it is operated below the full voltage level. Since the armature draws more current than the shunt field, the control resistors were much larger than those used for the field rheostat. During the 1950s and 1960s SCRs were used for this type of current control. The SCR was able to control the armature current since it was capable of controlling several hundred amperes. In Chapter 11 we provided an in-depth explanation of the DC motor drive. Torque Characteristics The armature's torque increases as the motor gains speed due to the fact that the shunt motor's torque is directly proportional to the armature current. When the motor is starting and speed is very low, the motor has very little torque. After the motor reaches full rpm, its torque is at its fullest potential. In fact, if the shunt field current is reduced slightly when the motor is at full rpm, the rpm will increase slightly and the motor's torque will also in-crease slightly. This type of automatic control makes the shunt motor a good choice for applications where constant speed is required, even though the torque will vary slightly due to changes in the load. Figure 12-15 shows the torque/speed curve for the shunt motor. From this diagram you can see that the speed of the shunt motor stays fairly constant throughout its load range and drops slightly when it is drawing the largest current. FIGURE 12-15 A curve that shows the armature current versus the armature speed for a shunt motor. Notice that the speed of a shunt motor is nearly constant. FIGURE 12-16 Diagram of a shunt motor connected to a reversing motor starter. Notice that the shunt field is connected across the armature and it is not reversed when the armature is reversed. Reversing the Rotation The direction of rotation of a DC shunt motor can be reversed by changing the polarity of either the armature coil or the field coil. In this application the armature coil is usually changed, as was the case with the series motor. Figure 12-16 shows the electrical diagram of a DC shunt motor connected to a forward and reversing motor starter. You should notice that the Fl and F2 terminals of the shunt field are connected directly to the power supply, and the Al and A2 terminals of the armature winding are connected to the reversing starter. When the FMS is energized, its contacts connect the Al lead to the positive power supply terminal and the A2 lead to the negative power supply terminal. The Fl motor lead is connected directly to the positive terminal of the power supply and the F2 lead is connected to the negative terminal. When the motor is wired in this configuration, it will begin to run in the forward direction. When the RMS is energized, its contacts reverse the armature wires so that the Al lead is connected to the negative power supply terminal and the A2 lead is connected to the positive power supply terminal. The field leads are connected directly to the power supply, so their polarity is not changed. Since the field's polarity has remained the same and the armature's polarity has reversed, the motor will begin to rotate in the reverse direction. The control part of the diagram shows that when the FMS coil is energized, the RMS coil is locked out. Installing a Shunt motor A shunt motor can be installed easily. The motor is generally used in belt-drive applications. This means that the installation procedure should be broken into two sections, which include the mechanical installation of the motor and its load, and the installation of electrical wiring and controls. When the mechanical part of the installation is completed, the alignment of the motor shaft and the load shaft should be checked. If the alignment is not true, the load will cause an undue stress on the armature bearing and there is the possibility of the load vibrating and causing damage to it and the motor. After the alignment is checked, the tension on the belt should also be tested. As a rule of thumb, you should have about V2 to 1/4 inch of play in the belt when it is properly tensioned. Several tension measurement devices are available to determine when a belt is tensioned properly. The belt tension can also be compared to the amount of current the motor draws. The motor must have its electrical installation completed to use this method. The motor should be started, and if it is drawing too much current, the belt should be loosened slightly but not enough to allow the load to slip. If the belt is slipping, it can be tightened to the point where the motor is able to start successfully and not draw current over its rating. The electrical installation can be completed before, after, or during the mechanical installation. The first step in this procedure is to locate the field and armature leads in the motor and prepare them for field connections. If the motor is connected to magnetic or manual across the line starter, the Fl field coil wire can be connected to the Al armature lead and an interconnecting wire, which will be used to connect these leads to the Tl terminal on the motor starter. The F2 lead can be connected to the A2 lead and a second wire, which will connect these leads to the T2 motor starter terminal. When these connections are completed, field and armature leads should be replaced back into the motor and the field wiring cover or motor access plate should be replaced. Next the DC power supply's positive and negative leads should be connected to the motor starter's LI and L2 terminals, respectively. After all of the load wires are connected, any pilot devices or control circuitry should be installed and connected. The control circuit should be tested with the load voltage disconnected from the motor. If the control circuit uses the same power source as the motor, the load circuit can be isolated so the motor will not try to start by disconnecting the wire at terminal L2 on the motor starter. Operate the control circuit several times to ensure that it is wired correctly and operating properly. After you have tested the control circuit, the lead can be replaced to the L2 terminal of the motor starter and the motor can be started and tested for proper operation. Be sure to check the motor's voltage and current while it is under load to ensure that it is operating correctly. It is also important to check the motor's temperature periodically until you are satisfied the motor is operating correctly. If the motor is connected to a reversing starter or reduced-voltage starting circuit, their operation should also be tested. You may need to read the material in Section 15.3.6 to fully understand the operation of these methods of starting the motor using reduced-voltage methods. If the motor is not operating correctly or develops a fault, a troubleshooting procedure should be used to test the motor and locate the problem. Troubleshooting When a DC shunt motor develops a fault, you must be able to locate the problem quickly and return the motor to service or have it replaced. The most likely problems to occur with the shunt motor include loss of supply voltage or an open in either the shunt winding or the armature winding. Other problems may arise that cause the motor to run abnormally hot even though it continues to drive the load. The motor will show different symptoms for each of these problems, which will make the troubleshooting procedure easier. When you are called to troubleshoot the shunt motor, it is important to determine if the problem occurs while the motor is running or when it is trying to start. If the motor will not start, you should listen to see if the motor is humming and trying to start. When the supply voltage has been interrupted due to a blown fuse or a de-energized control circuit, the motor will not be able to draw any current and it will be silent when you try to start it. You can also determine that the supply voltage has been lost by measuring it with a voltmeter at the starter's LI and L2 terminals. If no voltage is present at the load terminals, you should check for voltage at the starter's Tl and T2 terminals. If voltage is present here but not at the load terminals, it indicates that the motor starter is de-energized or defective. If no voltage is present at the Tl and T2 terminals, it indicates that supply voltage has been lost prior to the motor starter. You will need to check the supply fuses and the rest of the supply circuit to locate the fault. If the motor tries to start and hums loudly, it indicates that the supply voltage is present. The problem in this case is probably due to an open field winding or armature winding. It could also be caused by the supply voltage being too low. The most likely problem will be an open in the field winding since it is made from small-gauge wire. The open can occur if the field winding draws too much current or develops a short circuit between the insulation in the coils. The best way to test the field is to remove supply voltage to the motor by opening the disconnect or de-energizing the motor starter. Be sure to use a lockout when you are working on the motor after the disconnect has been opened. The lockout is a device that is placed on the handle of the disconnect after the handle is placed in the off position, and it allows a padlock to be placed around it so it cannot be removed until the technician has completed the work on the circuit. If lockout has extra holes, additional padlocks can be placed on it by other technicians who are also working on this system. This ensures that the power cannot be returned to the system until all technicians have removed their padlocks. The lockout will be explained in detail in the chapter on motor controls later in this text. After power has been removed, the field terminals should be isolated from the armature coil. This can be accomplished by disconnecting one set of leads where the field and armature are connected together. Remember that the field and armature are connected in parallel and if they are not isolated, your continuity test will show a completed circuit even if one of the two windings has an open. When you have the field coil isolated from the armature coil, you can proceed with the continuity test. Be sure to use the R X 1k or R X 10k setting on the ohmmeter because the resistance in the field coil will be very high since the field coil may be wound from several thousand feet of wire. If the field winding test indicates the field winding is good, you should continue the procedure and test the armature winding for continuity. The armature winding test may show that an open has developed from the coil burning open or from a problem with the brushes. Since the brushes may be part of the fault, they should be visually inspected and replaced if they are worn or not seating properly. If the commutator is also damaged, the armature should be removed, so the commutator can be turned down on a lathe. If either the field winding or the armature winding has developed an open circuit, the motor will have to be removed and replaced. In some larger motors it will be possible to change the armature by itself rather than remove and replace the entire motor. If the motor operates but draws excessive current or heats up, the motor should be tested for loose or shorting coils. Field coils may tend to come loose and cause the motor to vibrate and overheat, or the armature coils may come loose from their slots and cause problems. If the motor continues to overheat or operate roughly, the motor should be removed and sent to a motor rebuilding shop so that a more in-depth test may be performed to find the problem before the motor is permanently damaged by the heat. GEM Motors in the News 2014-04-02 16:50:57 ^ Go Back to Blog Top GEM Electric Cars By: Terry Parkhurst Filed Under: NEV (Neighborhood Electric Vehicle) - Electric cars have been called “the next big thing” many times in the past, thanks to their quiet motors, clean (nonexistent) exhaust, and the ubiquity of electric power in every other part of our lives. Remember how executives at General Motors, back in 1980, were predicting that by 1990, fully 10% of that company’s product line would be powered solely by electric power? A decade later, GM built a state-of-the-art electric car, the EV-1, to meet the mandates of CARB (California Air Resources Board). Later, they literally destroyed the EV-1, allowing a few to survive in places such as the Peterson Museum in Los Angeles. Chrysler Corporation, for its part, built a rather cleverly engineered electric minivan starting in 1993; most were sold to utilities and other fleets, but some were also sold to individuals. Many people managed to buy a Chrysler electric minivan (“TEVan”) second-hand, at auction, and rolled around in quiet style for years afterwards, because the NiCad batteries in early models could be replaced with new units (an automatic watering system kept the batteries alive for around 100,000 miles, after which they could be recycled). A later version, called EPIC, was sold starting in 1997; it had double the voltage of the first one, extending the range past 50 miles, and switched to an advanced lead-acid battery pack. Chrysler had also worked on electric cars back in the 1970s, producing (in cooperation with Jet) a four-passenger electric city car, which were purchased by some organizations but apparently never officially sold. Likewise, the Neon was originally to be sold in diesel and electric versions. Even more prescient, or at least more determined, was the Tag 2 group in Livonia, Michigan, a group of engineers that produced their first electric vehicle in 1992. Mike Hofer, a North Dakota businessman, recognized the potential of the little car, and assembled a group of investors. He then purchased the company and moved the entire operation to Fargo in December of 1997. The result was GEM, or Global Electric Motorcar, which is still being built in Fargo, North Dakota, as what is a wholly owned subsidiary of Chrysler LLC. The Fargo factory manufactured its first vehicle in April 1998. The 48-volt GEM could accommodate two passengers and had a top speed of just 20 miles per hour; however, less than two months later, a breakthrough in market conditions occurred when NHTSA (National Traffic Safety Administration) designated a new class of motor vehicles: the low speed vehicle called the neighborhood electric vehicle. While a neighborhood electric vehicle didn’t have to go faster than 35 mph, the NHSTA did require some things: a safety glass windshield, turn signals, mirrors, windshield wipers, headlights, taillights, and seat belts. The idea behind the neighborhood vehicle was to address both air pollution and urban sprawl; the latter was based on the theory that if you increased density in the city, there’d be less of the population going outside of the city to live. Those living in the denser environs of the city would probably want transportation other than the bus sometimes. That’s where neighborhood electric vehicles would come into play. In November of 1998, the first utility version of the GEM was produced. These became part of the fleet of utility vehicles at Luke Air Force based, the largest fighter pilot training facility in the world, near Phoenix, Arizona; as of 2001, there were 100 GEM vehicles in service at Luke, out of a fleet of 831 vehicles. By the end of 1999, total production reached 1,826 vehicles; and by the end of June 2000, the monthly output had surpassed 500 vehicles. By the end of December 2000, total production had hit 5,000 vehicles. At that time, a past Chrysler executive joined up with a competing electric-car company. Some claim it was out of spite that DaimlerChrysler quickly acquired GEM; others claim that it was, as DaimlerChrysler said, a matter of building zero-emission vehicles to supplement the slow, expensive research into hydrogen power. By then, no less than 37 states had accepted NHTSA’s ruling on low speed vehicles as legal of city streets. By 2001, the GEM line of vehicles included both two and four passenger electric vehicles, as well as two utility vehicles with short and long boxes. The curb weight of the two passenger machine was just 1,100 pounds, including batteries; while the curb weight of the long box utility vehicle was just 140 pounds more. Power was the same for the GEM fleet: a 72 volt shunt General Electric motor and six, industrial 12-volt batteries. But the major selling point was the proprietary 72-volt DC on-board charger, which employed the standard 110-volt AC house current. GEM Motorcars LLC held an Environmental Solutions Summit in Anaheim, California in 2001. Larry Oswald, who was then CEO of GEM as well as a PhD in aerospace engineering, said that he saw his company’s vehicles as “the early stages of a long range view towards a fuel cell future.” At that time, we drove the GEM cars at a ride-and-drive event. They had plenty of torque, a hallmark of electric vehicles, and good handling, partly because of the independent front suspension and rear trailing-arm suspension. Rack and pinion steering gave a precise feel; having the batteries close to the ground probably helped the stable feel. The width of just 55 inches was akin to – well, a golf cart. The range of these vehicles was about 30 to 35 miles, dependent upon ambient temperature and terrain, enough for local grocery shopping or even typical commuting; when stopped, the GEMs consume barely any power, so stop and go traffic is not a problem. The rise of the price of oil has only helped GEM. As of July of this year, shipments have jumped 30% from last year's second quarter, with some of its 150 dealerships around the country tripling their sales, according to the Wall Street Journal. While the vehicles still look essentially the same, there have been some major improvements since Larry Oswald’s presentation. Oswald himself has retired, and Bruce Coventry is now the chief operating officer of GEM Motorcars LLC. Rick Kasper has since replaced Ken Montler, GEM’s President; he holds a degree in electronic engineering technology from the University of Washington. The battery pack in the current GEM vehicles is the gelatin type, with low maintenance. The steering geometry has been reworked to allow even more precise steering; and the responsive of the electric motor is better. There are even performance upgrades for GEM cars and utility vehicles. The 7 horsepower performance package – yes, “performance” package – includes scoops, a heat sink, and chrome emblems. Pricing now ranges from $6,795 for a basic two seater to a high of $17,995 for a six passenger vehicle with a truck that looks akin to something such as the add-ons you might see on a vintage motorcar of the 1920s or 1930s. Mike Nickoloff, commercial fleet and GEM sales manager for Star Chrysler Jeep & GEM in Glendale, CA said, “The demand has generally been more steady, with no big spike. But this summer, we saw a 50% increase. Orange County and San Francisco, places that are friendlier to electric cars, have done even better. There’s a 12 month unlimited warranty; and an additional service contract buys a person another 36 months of (warranty) service. The nice thing is you can call the manufacturer up in Fargo. It’s a lot easier than trying to connect with a zone service rep for Chrysler. “I sell maybe three or four GEM cars a month; and I usually ship them on a flatbed to my clients. In fact, I’m taking one over to San Marino, the high rent district, tomorrow.” If you’re wondering what the next step is for urban transportation, this may be it. But that’s not to say there aren’t hurdles to overcome. “We need infrastructure, “ admitted Joan Michelson, spokesperson for GEM, in a recent phone interview. While there is still a proprietary on-board charger for GEM cars, they do, after all, have to plug into something. “We need charging stations as ubiquitous as gas stations.” Utilities appear happy with cars like the GEM, since they even out their demand (indeed, the Edison companies were proponents of electric cars in the early 1900s). Normally, utilities see peak demand during the day, and they need to have extra powerplants to fill that demand; but those plants often sit idle at night, an apparently needless expense. The ideal would be to either have less demand during the day (prime air conditioning, industrial use, and computer use times), or more at night. Overnight GEM recharging would provide additional utility revenue without additional capital expense. The newest GEM line is the Peapod, designed to have an iPod appearance along with integrated iPod and iPhone controls; this model was introduced in 2008 and is a substantial upgrade to the past line. 2014-04-02 16:47:43 ^ Go Back to Blog Top Bigger, better, faster! By: GEM Car Owners Group Filed Under: NEV (Neighborhood Electric Vehicle) - BIGGER D&D Motor Systems electric motor- Some "must know" information. So you want to change out the original 5 hp electric motor and up it to the 7.5 hp D&D Motor Systems electric motor option? Chances are you want to boost up the top speed, and avoid having those lines of traffic build up behind you in the 35 mph zones! I RECOMMEND THAT YOU DO NOT UPGRADE THE electric motor UNTIL YOU HAVE UPGRADED THE WHEELS AND TIRES TO NO-LESS-THAN 14" TIRES. STEP 1- D&D Motor Systems electric motor selection. Although there are several sources online that have D&D Motor Systems electric motors available, I would strongly recommend that you purchase the D&D Motor Systems electric motor from a supplier with a strong history and a verifiable reputation. Through suggestions and research, one company I would strongly recommend would be ride-4fun.com. Ensure you do not procure and non-Blue colored motor which illsutrates that its the true US made D&D Motor Systems electric motor. You will understand why as we go. When selecting a supplier, verify "new or rebuilt", the manufacturer, (ie: General Electric), and warrantee /return policy. Also, check on the shipping rates. Some parts suppliers have hidden "processing and handling fees" for certain parts that can be extremely expensive. Also, check on rebates for returning the core. If there is not, you may consider selling the original GE electric motor on line to help offset the cost of a new D&D Motor Systems electric motor, typically around $800-. When you get the new D&D Motor Systems electric motor, please review the instructions included with the D&D Motor Systems electric motor, and inspect it for damage from shipping. Keep the D&D Motor Systems electric motor in the box, to prevent any damage from falling, until physically installing the D&D Motor Systems electric motor. STEP 2- Removal of the old GE electric motor. It is extremely important that all due caution be used when servicing your GEM. First and foremost, turn the main power control switch to "off" and use wheel chocks on the rear tires. Use the manufacturer recommended jacking points to lift the front right of the vehicle until the tire is just off the ground. Place a proper jack stand under the frame in the jacking point nearest the front right tire without blocking the end of the electric motor. Remove the tire, and set it aside. First, note the polarity and position of the power cables as they relate to the D&D Motor Systems electric motor, then remove the cables from the D&D Motor Systems electric motor. Make sure to protect the cable ends! Next you will need to identify and then remove the mount bolts. (D&D Motor Systems has a great video on this process.) When you are pulling the D&D Motor Systems electric motor out of the trans-axle, note the general position of the landmarks on the old D&D Motor Systems electric motor, as the new D&D Motor Systems electric motor will need to go back into the trans-axle in relatively the same position. This is very important, to prevent possible damage to your new D&D Motor Systems electric motor. Inspect the GE electric motor end for excessive wear, chips or metal shavings, which could indicate that your trans-axle may need service BEFORE installing the new D&D Motor Systems electric motor. If there is no sign of damage, proceed with the next step. Clean both the bolts and sockets for the D&D Motor Systems electric motor mounting. You will use "Lok-tite" or a similar product when installing the new D&D Motor Systems electric motor...always... STEP 3- Installation of the new D&D Motor Systems electric motor. Remember to orient the new D&D Motor Systems electric motor landmarks to relatively the same position as the old GE electric motor came out. The D&D Motor Systems electric motor should slide back in with ease. If there is resistance, DON'T FORCE IT! Re-adjust the D&D Motor Systems electric motor by gently turning the body back and forth, with GENTLE pressure until the D&D Motor Systems electric motor slides in easily. Support the D&D Motor Systems electric motor until you have the D&D Motor Systems electric motor mounting bolts back in place. Be sure to not over tighten the bolts. Keep the bolts evenly torqued, and visually inspect the D&D Motor Systems electric motor position before connecting the power cables. Once you have re-connected the power cables, double-check your work before remounting the tire and lowering the vehicle to the ground. STEP 4- Test the D&D Motor Systems electric motor. Turn the main power switch back "on". Operate your vehicle for a few minutes to ensure that the D&D Motor Systems electric motor engages, no unusual noises are heard, and the D&D Motor Systems electric motor operates smoothly. Now, PARK IT! You aren't quite done! STEP 5- Remove the control unit. Your control unit is programmed to handle the 5hp D&D Motor Systems electric motor, and although your vehicle will run with the old programming, it is not running as it needs to. DO NOT attempt to continuously operate your vehicle without reprogramming this unit. (D&D Motor Systems includes reprogramming with the cost of the D&D Motor Systems electric motor!) If you purchased your D&D Motor Systems electric motor from D&D Motor Systems, there is an information sheet you must fill out and include with your control unit when you ship it to them at the address provided on the form. Remember to follow the instructions on the video on their website. Always turn the main power "off" before performing any service on your vehicle. Once you receive the re-programmed control unit, install it in the same position, and complete all steps before turning the main power switch back "on". WHAT HAVE YOU ACCOMPLISHED?- Your stock 5hp GE electric motor is designed and programmed to perform at 5hp peak power for approximately 30 minutes. The D&D Motor Systems electric motor with reprogrammed control unit is configured to operate at 7.5 hp for 30 minutes. The increase torque to the wheels provides more efficient operation, added to the 14" tires, you can expect as much as 35 mph, and better handling. 2008-08-13 22:08:09 ^ Go Back to Blog Top A Holy Roller By: Jura Koncius Filed Under: NEV (Neighborhood Electric Vehicle) - The pope who wears Prada has a new set of chic custom wheels. Pope Benedict XVI, who has made headlines with his high-style red designer loafers and his Gucci shades, is tooling around the grounds of Vatican City in an electric car outfitted in luxurious Natuzzi Italian white leather. His latest fashion statement was donated to the pontiff by Global Electric Motorcars (GEM), a subsidiary of DaimlerChrysler, and Natuzzi. "It was a very special project and an honor to be involved in it," said Daniel Tranchini, chief global sales and marketing officer for Natuzzi, the world's largest manufacturer of leather upholstery, calling us from the International Furniture Fair in Cologne, Germany. The car, which bears a vague resemblance to a golf cart, has the papal seal on the front and back and was made for short hops behind the walls of Vatican City. No word on whether there is a papal putting green out there. 2011-09-02 07:00:00 ^ Go Back to Blog Top Buchanan calls for bipartisan effort to convert nation to "green" energy By: Domenick Yoney Filed Under: NEV (Neighborhood Electric Vehicle) - Vern Buchanan (R), the Congressman representing the Sarasota, FL area, is one politician who sees the "green" light. While visiting with solar and electric car maker, Cruise Car Inc, whose manufacturing and sales operation is in his district, the lawmaker made a plea for a national bipartisan effort to make the switch from fossil fuels to more environmentally-friendly energy sources. Speaking to the company's employees and assembled media, Buchanan said, "My sense is we've been misled as Americans in many ways for the last 25 years in terms of our energy and where we're going to get it. Solar, alternate energy, all that stuff is possible; it'll create jobs, it'll make a difference." Proof of that difference was all around him. While obviously not the transportation solution for everybody, Cruise Car is doing a booming business. There's a 60 to 90 day waiting list for some of their vehicles, which can go up to 62 miles on a charge and are powered by the sun, though they can be plugged in for extra charging if necessary. The company is doubling its 10 employees this year and will be moving to a new facility (and doing more hiring) to keep up with an exponential increase in demand. Hopefully, more of our representatives will open their eyes to the many benefits of a greener economy and make the changes needed to speed things along. [Source: Bradenton Herald] 2008-08-13 18:33:58 ^ Go Back to Blog Top Phillipine police roll on patrol in a NEV By: Domenick Yoney Filed Under: NEV (Neighborhood Electric Vehicle) - The price of gas is getting out of hand everywhere. Ok, maybe not Venezuela, where its cheaper than our bottled water at ¢15 a gallon, but almost everywhere else, it's expensive. In the Philippines its so costly ($4.50 gallon in a country where, according to the Philippine National Statistics Office, the average household income is about $4,000 USD a year) that the Philippine National Police (PNP) has started testing neighborhood electric vehicles (NEV) with the goal of putting them into regular action. The customized vehicle can accommodate 4 adults and comes with a police light bar and "Polis" markings. There are no gears to shift, so operation is simple. With a top speed of 30 km/h (slow) they won't be involved in any high-speed chases but they're still adequate for routine patrols and providing police visibility. The force is also considering implementing bicycles. Made in the USA The only DC Motors Manufacturer in America Fast, Reliable Shipping We provide fast 2-3 day shipping in the USA Engineering Expertise Unparallel customer support from our expert engineers × FAQs Regarding Series and Regen Motors Understanding the differences between motor types What Is a Shunt or Regen or SEPEX Motor? The shunt motor is different from the series motor in that the field winding is connected in parallel with the armature instead of in series. Since the field winding is placed in parallel with the armature, it is called a shunt winding and the motor is called a shunt motor. Key Characteristics: Field Winding: Made of small-gauge wire with many turns (hundreds to thousands) Starting Torque: Very low starting torque compared to series motors Speed Control: Excellent speed regulation - maintains constant speed under varying loads Current Draw: Low current due to high resistance of shunt coil How It Works: When voltage is applied, the high resistance of the shunt coil keeps overall current flow low. As the armature begins to turn, it produces back EMF (electromotive force). This back EMF helps maintain constant speed - if the load increases and the motor slows down, less back EMF is produced, allowing more current to flow and increasing torque to maintain speed. Speed Control Methods: Field Current Control: Adjusting voltage to the shunt field (10-20% speed variation) Armature Voltage Control: Regulating voltage applied to the armature winding Important: Shunt motors maintain nearly constant speed, making them ideal for applications requiring consistent rpm despite load variations. What Are Series DC Motors? The series motor provides high starting torque and is able to move very large shaft loads when first energized. The field winding in this motor is wired in series with the armature winding - this gives the series motor its name. Key Characteristics: Field Winding: Made of heavy-gauge wire or copper bar stock with few turns Starting Torque: Extremely high starting torque - can handle massive loads Current Capacity: Can safely carry very large currents (hundreds to thousands of amperes) Speed Variation: Speed varies significantly with load How It Works: Since the field carries the same current as the armature, when voltage is first applied, large current flows through both windings creating a very strong magnetic field. This produces maximum torque at startup. As the armature rotates, it generates back EMF which reduces current flow, automatically lowering torque as the load begins to move. Series motor with flat wire field coils Common Applications: Automobile starter motors (may draw 500+ amperes) Electric hoists and cranes Electric trains and traction systems Power tools (drills, saws, screwdrivers) ⚠ Warning - Runaway Risk: If a series motor loses its load (broken shaft, sheared pin), it can run away and destroy itself. The motor will accelerate uncontrollably, causing armature windings to be pulled loose by centrifugal force. Series motors should always have runaway protection. Speed-Current Relationship: Series motors have an inverse relationship between speed and current: Low current = High speed (light load or no load - dangerous!) High current = Low speed (heavy load - maximum torque) Pros and Cons of Using Series vs Separately Excited (SEPEX) DC Motors Series DC Motor ✓ Advantages: High Starting Torque: Ideal for traction applications (trains, cranes, elevators) Simple Design: Fewer components, easier maintenance Self-Regulating: Speed naturally decreases as load increases Low Cost: No external field power supply needed ✗ Disadvantages: Poor Speed Regulation: Speed varies significantly with load Runaway Risk: Can destroy itself if load is removed Limited Reversibility: Must switch both field and armature Not for Constant Speed: Unsuitable for precision applications SEPEX/Regen/Shunt Motor ✓ Advantages: Excellent Speed Control: Precise speed control over wide range Stable Under Load: Maintains constant speed despite load changes Easy Reversibility: Simple to reverse direction Better Efficiency: Field excitation can be optimized for conditions ✗ Disadvantages: More Complex: Requires separate field power supply Lower Starting Torque: Not as strong as series motor at startup Additional Controls: Needs external speed controllers Higher Maintenance: More components to maintain Quick Selection Guide: Choose a Series DC Motor when: High starting torque is essential Speed variations under load are acceptable Applications: Traction systems, cranes, hoists, starter motors Choose a Separately Excited (SEPEX/Regen/Shunt) DC Motor when: Precise speed control is required Stable speed operation is essential Applications: Industrial machinery, robotics, manufacturing equipment Series Motor Flat wire field coils Few turns, heavy gauge Shunt/Regen Motor Round wire field coils Many turns, fine gauge Need help determining which motor type is right for your application? Contact our technical team for personalized recommendations. D&D Motor Systems, Inc Send Market Segments Golf Carts Autohauler Pump Motors NEV Mining Go Karts All Markets Content Frequently Asked Questions Technical Tips Photo Gallery Beginner's Guide to Motors DC vs AC Golf Carts Quote Request Replacement Motor Quote Pump Motor Quote Drive Motor Quote Company About Us Contact Us © 2026 D&D Motor Systems, Inc. All rights reserved. 304 W 2nd Street East Syracuse NY 13057Monday - Friday, 8AM - 4PM EST
Identifikace uložené verze
SHA-256: 7900074cd3dbf9354de10de14387842542fd12fe7fe782226ea7f1dfaeef644d